NorComp(4494)

Compare Image Name Manufacturer Pricing(USD) Quantity Weight(Kg) Size(LxWxH) Part Status Type Series Mount Mounting Type Operating Temperature Packaging Moisture Sensitivity Level (MSL) Termination Max Operating Temperature Min Operating Temperature Voltage - Rated RoHS Status Published Datasheet Current Rating Package / Case Length Height Width Voltage - Rated AC Color Lead Free Material Factory Lead Time Ratings REACH SVHC Number of Pins Accessory Type Pbfree Code Connector Type Number of Positions Gender MIL Conformance DIN Conformance IEC Conformance Filter Feature Mixed Contacts Option Number of Contacts Mating Information Contact Gender Empty Shell Housing Color Contact Finish - Mating Number of Ports Flammability Rating ECCN Code Contact Material Contact Plating Housing Material Total Number of Contacts Reach Compliance Code Ingress Protection HTS Code Insulation Resistance Dielectric Material JESD-609 Code Feature Reference Standard Subcategory Body Material Connector Type A Connector Type B Insulation Material Contact Form Body Breadth Termination Type Gender Type A Gender Type B Number of Rows Wire Gauge Wire Gauge (Max) Wire Gauge (Min) Current Rating (Amps) Includes Insulation Shell Material Contact Finish Termination Plating Contact Finish Reliability Number Of PCB Rows PCB Contact Pattern Mating Contact Pitch PCB Contact Row Spacing Shell Finish Rated Current (Signal) Dielectric Withstanding Voltage UL Flammability Code Number of Power Positions Contact Finish Thickness Material Flammability Rating Convert From (Adapter End) Convert To (Adapter End) Connector Style Contact Type Flange Feature Shell Size, Connector Layout Shell Material, Finish Backset Spacing Shell Size - Insert Contact Termination Note Termination Finish
680S11W1103L201 680S11W1103L201 NorComp
RFQ

Min: 1

Mult: 1

download Seal-D 680S Panel Mount -55°C~155°C Tray 1 (Unlimited) Solder Cup ROHS3 Compliant 2012 /files/norcompinc-780m44213r001-datasheets-2740.pdf 5A Black 14 Weeks Dust Tight, IP67, Waterproof No SVHC Plug, Male Pins 11 (10 + 1 Power) Male 11 Copper Alloy Gold IP67 - Dust Tight, Waterproof Polybutylene Terephthalate (PBT) Grounding Indents Steel PBT Machined 2 5A 20A Insulated Steel Nickel Gold 1 Flash UL94 V-0 D-Sub, Combo Signal and Power Housing/Shell (Unthreaded) 2 DA A - 11C1 11W1 Steel, Nickel Plated
179-037-313R571 179-037-313R571 NorComp
RFQ

Min: 1

Mult: 1

download 179 Through Hole Board Edge, Through Hole, Right Angle -55°C~105°C Tray Solder ROHS3 Compliant 2009 /files/norcompinc-179009313r571-datasheets-1642.pdf 5A 69.2mm 36.1mm 25.4mm Black Lead Free 14 Weeks yes Plug, Male Pins; Receptacle, Female Sockets 37, 37 Female to Male 37 2 UL94 V-0 Brass Nylon 1000Ohm Polyamide (PA9T), Nylon 9T e4 Board Lock, Grounding Indents, Shielded UL D Type Connectors Stamped 0.494 inch 2, 2 Steel Nickel Gold COMMERCIAL 2+2 STAGGERED 0.109 inch 3.7338 mm 5A 1000VAC V Flash UL94 V-0 D-Sub - Stacked Signal Mating Side, Female Screwlock (4-40) 4 DC C ; 4 DC C Steel, Nickel Plated 0.318 (8.08mm)
195-078-213L001 195-078-213L001 NorComp
RFQ

Min: 1

Mult: 1

download 195 Through Hole Panel Mount, Through Hole -55°C~125°C Tray Not Applicable Solder 500V ROHS3 Compliant 2009 /files/norcompinc-195015213l551-datasheets-4897.pdf 2A 66.9mm 13.1mm 12.5mm Black Lead Free 14 Weeks Receptacle, Female Sockets 78 Female UL94 V-0 Phosphor Bronze PBT Polybutylene Terephthalate (PBT) Shielded Polyester Stamped 4 Insulated Steel Nickel Gold Flash UL94 V-0 D-Sub, High Density Signal Housing/Shell (Unthreaded) 5 DD D High Density Steel, Nickel Plated
773-E25-213R141 773-E25-213R141 NorComp
RFQ

Min: 1

Mult: 1

download Seal-D 773-E Through Hole Panel Mount, Through Hole, Right Angle -50°C~100°C Tray 1 (Unlimited) Solder ROHS3 Compliant 2012 /files/norcompinc-780m44213r001-datasheets-2740.pdf 5A White 14 Weeks Dust Tight, IP67, Waterproof yes Receptacle, Female Sockets 25 Female Brass Nylon IP67 - Dust Tight, Waterproof Polyamide (PA6T), Nylon 6T Mounting Brackets 2 Gold Flash UL94 V-0 D-Sub Signal Mating Side, Female Screwlock (4-40) 3 DB B Steel, Nickel Plated 0.283 (7.20mm)
173-E50-213R001 173-E50-213R001 NorComp
RFQ

Min: 1

Mult: 1

download 173-E, M Series Through Hole Through Hole, Right Angle -55°C~125°C Tray Solder ROHS3 Compliant 2005 /files/norcompinc-179037413r571-datasheets-2679.pdf 5A 69.3mm 15.4mm White Lead Free 14 Weeks yes Receptacle, Female Sockets 50 Female UL94 V-0 EAR99 Copper Nylon Polyamide (PA6T), Nylon 6T Machined 3 Gold Flash UL94 V-0 D-Sub Signal Housing/Shell (Unthreaded) 5 DD D Steel, Nickel Plated 0.283 (7.20mm)
684S21W1103L461 684S21W1103L461 NorComp
RFQ

Min: 1

Mult: 1

download Seal-D 684S Through Hole Board Edge, Through Hole, Right Angle -55°C~125°C Tray 1 (Unlimited) Solder ROHS3 Compliant 2011 /files/norcompinc-780m44213r001-datasheets-2740.pdf 5A Black 14 Weeks Dust Tight, IP67, Waterproof No SVHC yes Plug, Male Pins 21 (20 + 1 Power) Male 21 Copper Alloy PBT IP67 - Dust Tight, Waterproof Polybutylene Terephthalate (PBT), Glass Filled Board Lock, Grounding Indents, Mounting Brackets Steel 2 5A 40A Insulated Nickel Gold 1 Flash UL94 V-0 D-Sub, Combo Signal and Power Housing/Shell (4-40) 3 DB B - 21W1 Steel, Nickel Plated 0.395 (10.03mm)
172-050-142R021 172-050-142R021 NorComp
RFQ

Min: 1

Mult: 1

download 172, M Series Through Hole Panel Mount, Through Hole -50°C~100°C Tray Not Applicable Wire Wrap ROHS3 Compliant 2005 /files/norcompinc-172015142r001-datasheets-6492.pdf 5A 67mm 10.1mm 15.4mm Beige Lead Free 14 Weeks Plug, Male Pins 50 Male UL94 V-0 EAR99 Brass PBT Polybutylene Terephthalate (PBT), Polyester Grounding Indents Machined 3 Tin Gold Flash UL94 V-0 D-Sub Signal Board Side (4-40) 5 DD D Steel, Tin Plated
175-009-112R151 175-009-112R151 NorComp
RFQ

Min: 1

Mult: 1

download 175 Through Hole Panel Mount, Through Hole, Right Angle -50°C~100°C Tray Not Applicable Solder RoHS Compliant 2005 /files/norcomp-175009112r151-datasheets-0141.pdf 5A 30.8mm 12.6mm Beige Lead Free yes Plug, Male Pins 9 NO NO NO NO NO GENERAL PURPOSE NO UL94 V-0 Brass PBT 9 Polybutylene Terephthalate (PBT), Polyester Grounding Indents, Mounting Brackets Machined 2 Gold TIN Flash UL94 V-0 D-Sub Signal Mating Side, Female Screwlock (4-40) 1 DE E Steel, Tin Plated 0.454 (11.53mm)
191-015-113L591 191-015-113L591 NorComp
RFQ

Min: 1

Mult: 1

download 191 Through Hole Panel Mount, Through Hole -55°C~125°C Tray Not Applicable Solder ROHS3 Compliant 2009 /files/norcompinc-191009113l551-datasheets-8724.pdf 5A 39.2mm 12.1mm 12.5mm Black Lead Free 12 Weeks yes Plug, Male Pins 15 Male NO NO NO NO NO GENERAL PURPOSE NO UL94 V-0 Brass Polyester 15 Polyester Thermoplastic e3 Grounding Indents, Shielded 2 Gold 94V-0 Flash UL94 V-0 D-Sub Signal Mating Side, Female Screwlock (4-40) 2 DA A Steel, Nickel Plated
681-015-113R171 681-015-113R171 NorComp
RFQ

Min: 1

Mult: 1

download Seal-D 681 Through Hole Panel Mount, Through Hole, Right Angle -50°C~100°C Tray 1 (Unlimited) Solder RoHS Compliant 2012 /files/norcompinc-780m44213r001-datasheets-2740.pdf 2A Black 12 Weeks Dust Tight, IP66, Water Resistant yes Plug, Male Pins 15 Brass Nylon IP66 - Dust Tight, Water Resistant Polyamide (PA9T), Nylon 9T Ground Strap, Grounding Indents 3 Gold Flash UL94 V-0 D-Sub, High Density Signal Housing/Shell (4-40) 1 DE E High Density Steel, Nickel Plated 0.350 (8.89mm)
680-026-113R021 680-026-113R021 NorComp
RFQ

Min: 1

Mult: 1

download Seal-D 680 Through Hole Panel Mount, Through Hole -50°C~100°C Tray 1 (Unlimited) Solder RoHS Compliant 2012 /files/norcompinc-780m44213r001-datasheets-2740.pdf 5A 12 Weeks Dust Tight, IP66, Water Resistant yes Plug, Male Pins 26 Brass PBT IP66 - Dust Tight, Water Resistant Polybutylene Terephthalate (PBT) Grounding Indents Stamped 3 Gold Flash UL94 V-0 D-Sub, High Density Signal Board Side (4-40) 2 DA A High Density Steel, Nickel Plated
671-009-113R011 671-009-113R011 NorComp
RFQ

Min: 1

Mult: 1

download Seal-D 671 Through Hole Panel Mount, Through Hole -50°C~100°C Tray 1 (Unlimited) Solder RoHS Compliant 2012 /files/norcompinc-780m44213r001-datasheets-2740.pdf 5A Black 12 Weeks Dust Tight, IP66, Water Resistant yes Plug, Male Pins 9 Brass Nylon IP66 - Dust Tight, Water Resistant Polyamide (PA9T), Nylon 9T Grounding Indents Stamped 2 Gold Flash UL94 V-0 D-Sub Signal Board Side (4-40) 1 DE E Steel, Nickel Plated
680-015-103L031 680-015-103L031 NorComp
RFQ

Min: 1

Mult: 1

download Seal-D 680 Free Hanging, Panel Panel Mount -50°C~100°C Tray 1 (Unlimited) Solder Cup RoHS Compliant 2012 /files/norcompinc-780m44213r001-datasheets-2740.pdf 5A 12 Weeks Dust Tight, IP66, Water Resistant yes Plug, Male Pins 15 Brass PBT IP66 - Dust Tight, Water Resistant Polybutylene Terephthalate (PBT) Grounding Indents Stamped 3 Gold Flash UL94 V-0 D-Sub, High Density Signal Mating Side (4-40) 1 DE E High Density Steel, Nickel Plated
RJADK25P7080831 RJADK25P7080831 NorComp
RFQ

Min: 1

Mult: 1

download RJADK Bulk ROHS3 Compliant 2007 /files/norcompinc-rjadk25p7080811-datasheets-8023.pdf Gray 14 Weeks No SVHC 25 D-Sub, Standard RJ45 Male Female D-Sub, 25 Pin Male Modular, Female Jack, 8p8c (RJ45)
110-014-203-001 110-014-203-001 NorComp
RFQ

Min: 1

Mult: 1

download SCSI Centronics, 110- Free Hanging Free Hanging (In-Line) Not Applicable Solder Cup Non-RoHS Compliant 2002 /files/norcompinc-110014203001-datasheets-0019.pdf Contains Lead Receptacle 14 Female 14 UL94 V-0 Gold Plastic Assembly Hardware, Backshell, Bail Lock, Strain Relief 2 Gold Flash Outer Shroud Contacts Housing/Shell (Unthreaded)
111-014-103-001 111-014-103-001 NorComp
RFQ

Min: 1

Mult: 1

download SCSI 111 Free Hanging Free Hanging (In-Line) Not Applicable Solder Cup Non-RoHS Compliant 2002 /files/norcompinc-111050103001-datasheets-0047.pdf Contains Lead Plug 14 Male 14 Blue UL94 V-0 Gold Plastic 2 Gold Flash Center Strip Contacts Housing/Shell (Unthreaded)
111-024-103L001 111-024-103L001 NorComp
RFQ

Min: 1

Mult: 1

download SCSI 111 Free Hanging Free Hanging (In-Line) Not Applicable Solder Cup ROHS3 Compliant 2014 /files/norcompinc-111024103l001-datasheets-3212.pdf 5A Lead Free 14 Weeks No SVHC yes Plug 24 Male Blue UL94 V-0 Bronze Plastic 2 Gold Flash Center Strip Contacts Housing/Shell (Unthreaded)
111-036-113L001 111-036-113L001 NorComp
RFQ

Min: 1

Mult: 1

download SCSI 111 Through Hole Through Hole Not Applicable Solder ROHS3 Compliant 2014 /files/norcompinc-111050113l001-datasheets-4109.pdf 5A Lead Free 14 Weeks No SVHC yes Plug 36 Male Blue UL94 V-0 Bronze Plastic 2 Gold Flash Center Strip Contacts Housing/Shell (Unthreaded)
110-014-103L001 110-014-103L001 NorComp
RFQ

Min: 1

Mult: 1

download SCSI Centronics, 110- Free Hanging Free Hanging (In-Line) 1 (Unlimited) Solder Cup RoHS Compliant 2008 /files/norcompinc-110036103l001-datasheets-2021.pdf 5A Lead Free No SVHC Plug 14 Male NO NO NO NO NO GENERAL PURPOSE MULTIPLE MATING PARTS AVAILABLE NO UL94 V-0 EAR99 Copper Plastic 14 unknown 8536.69.40.30 Backshell, Bail Lock, Strain Relief 2 STEEL Gold NICKEL 94V-0 Flash Center Strip Contacts
854203M-DC 854203M-DC NorComp
RFQ

Min: 1

Mult: 1

download VULCON™. 1 (Unlimited) ROHS3 Compliant 2015 /files/norcompinc-854203mdc-datasheets-0873.pdf Metal Silver Brass 14 Weeks No SVHC Cap (Cover), Dust no M8
GCLP25F25F GCLP25F25F NorComp
RFQ

Min: 1

Mult: 1

download GCLP Free Hanging Panel Mount -55°C~105°C Not Applicable ROHS3 Compliant 2011 /files/norcompinc-gclp25f25f-datasheets-5264.pdf 14 Weeks No SVHC 25 Yellow EAR99 NOT SPECIFIED 8536.69.80.00 D-Sub, Standard D-Sub, Standard Female 2 5A 5 pcs - 1 Connector, 2 Jack Screws, 2 Nuts Gold Flash UL94 V-0 D-Sub, 25 Pin Female D-Sub, 25 Pin Female Gender Changer Steel, Tin Plated
GCHDLP26M26M GCHDLP26M26M NorComp
RFQ

Min: 1

Mult: 1

download GCLP Free Hanging Panel Mount -55°C~105°C Not Applicable ROHS3 Compliant 2011 /files/norcompinc-gchdlp26m26m-datasheets-5635.pdf 14 Weeks No SVHC 26 Yellow Grounding Indents D-Sub Male 3 3A 3 pcs - 1 Connector, 2 Jack Screws Gold Flash UL94 V-0 D-Sub, 26 HD, Male D-Sub, 26 HD, Male Gender Changer Steel, Tin Plated
180-001-170L001 180-001-170L001 NorComp
RFQ

Min: 1

Mult: 1

download Signal 180 Tape & Reel (TR) Not Applicable ROHS3 Compliant 2011 /files/norcompinc-180001170l001-datasheets-8503.pdf Lead Free 16 Weeks yes Male Pin Male Brass High Density (HD), Insulation Support Stamped 24-26 AWG 26 AWG 24 AWG Gold 10.0μin 0.25μm Male Pin Crimp Nickel
170-102-170L003 170-102-170L003 NorComp
RFQ

Min: 1

Mult: 1

download Signal 170 Bulk Not Applicable ROHS3 Compliant 2012 /files/norcompinc-170102170l001-datasheets-9906.pdf 14 Weeks yes Socket Brass Stamped 24-28 AWG 28 AWG 24 AWG Gold 30.0μin 0.76μm Female Socket Crimp
180-015-172L000 180-015-172L000 NorComp
RFQ

Min: 1

Mult: 1

download 180 Free Hanging Free Hanging (In-Line) -50°C~100°C Tray 1 (Unlimited) Crimp ROHS3 Compliant 2008 /files/norcompinc-180078172l000-datasheets-1445.pdf 5A 12.6mm 14 Weeks Plug for Male Contacts 15 Male Shielded 3 Insulated Steel Tin D-Sub, High Density Signal Housing/Shell (Unthreaded) 1 DE E High Density Steel, Tin Plated Contacts Not Included
180-015-273L000 180-015-273L000 NorComp
RFQ

Min: 1

Mult: 1

download 180 Free Hanging Free Hanging (In-Line) -50°C~100°C Tray Not Applicable Crimp ROHS3 Compliant 2008 /files/norcompinc-180078273l020-datasheets-1428.pdf 2A 015 30.8mm 12.6mm Lead Free 14 Weeks No SVHC yes Receptacle for Female Contacts 15 Receptacle NO NO NO NO NO GENERAL PURPOSE YES GOLD OVER NICKEL EAR99 BRASS 15 e4 Steel GLASS FILLED POLYBUTYLENE TEREPHTHALATE/NYLON66 3 Tin 94V-0 D-Sub, High Density Signal Housing/Shell (Unthreaded) 1 DE E High Density Steel, Nickel Plated Contacts Not Included
180-078-272L000 180-078-272L000 NorComp
RFQ

Min: 1

Mult: 1

download 180 Free Hanging Free Hanging (In-Line) -50°C~100°C Tray 1 (Unlimited) ROHS3 Compliant 2008 /files/norcompinc-180078273l020-datasheets-1428.pdf Lead Free 14 Weeks yes Receptacle for Female Contacts 78 Female NO NO NO NO NO GENERAL PURPOSE YES GOLD OVER NICKEL EAR99 BRASS 78 e4 Shielded GLASS FILLED POLYBUTYLENE TEREPHTHALATE/NYLON66 CRIMP 4 Gold (Au) - with Nickel (Ni) barrier TIN D-Sub, High Density Signal Housing/Shell (Unthreaded) 5 DD D High Density Steel, Tin Plated Contacts Not Included
180-044-172-020 180-044-172-020 NorComp
RFQ

Min: 1

Mult: 1

download 180 Free Hanging Free Hanging (In-Line) -50°C~100°C Bulk Not Applicable 100°C -50°C Non-RoHS Compliant 2002 /files/norcompinc-180026172020-datasheets-5966.pdf 53mm 12.6mm Black Contains Lead Plug for Male Contacts 44 44 Shielded 3 D-Sub, High Density Signal Cable Side (4-40) 3 DB B High Density Steel, Tin Plated Contacts Not Included
180-062-272L000 180-062-272L000 NorComp
RFQ

Min: 1

Mult: 1

download 180 Free Hanging Free Hanging (In-Line) -50°C~100°C Tray 1 (Unlimited) SMD/SMT ROHS3 Compliant 2008 /files/norcompinc-180078273l020-datasheets-1428.pdf 5A 14 Weeks yes Receptacle for Female Contacts 62 Female NO NO NO NO NO GENERAL PURPOSE YES Brass Gold 62 e4 Shielded Thermoplastic 3 Steel Tin TIN 94V-0 D-Sub, High Density Signal Housing/Shell (Unthreaded) 4 DC C High Density Steel, Tin Plated Contacts Not Included
170-050-273L010 170-050-273L010 NorComp
RFQ

Min: 1

Mult: 1

download 170 Free Hanging Free Hanging (In-Line) -50°C~125°C Tray Not Applicable Crimp ROHS3 Compliant 2008 /files/norcompinc-170015273l000-datasheets-3303.pdf 5A 67mm 15.3mm 500V Black Lead Free 14 Weeks Receptacle for Female Contacts 50 Female NO NO NO NO NO GENERAL PURPOSE YES GOLD EAR99 NOT SPECIFIED 50 Polybutylene Terephthalate (PBT) e4 3 Nickel 94V-0 D-Sub Signal Cable Side (4-40) 5 DD D Steel, Nickel Plated Contacts Not Included

In Stock

Please send RFQ , we will respond immediately.