NorComp(4494)

Compare Image Name Manufacturer Pricing(USD) Quantity Weight(Kg) Size(LxWxH) Part Status Type Series Mount Mounting Type Operating Temperature Packaging Moisture Sensitivity Level (MSL) Termination Voltage - Rated RoHS Status Published Datasheet Current Rating Length Height Width Voltage - Rated AC Color Lead Free Material Factory Lead Time Ratings REACH SVHC Number of Pins Accessory Type Pbfree Code Connector Type Number of Positions Gender MIL Conformance DIN Conformance IEC Conformance Filter Feature Mixed Contacts Option Number of Contacts Mating Information Contact Gender Empty Shell Housing Color Number of Ports Flammability Rating ECCN Code Additional Feature Contact Material Contact Plating Housing Material Total Number of Contacts Reach Compliance Code Ingress Protection HTS Code Wire/Cable Gauge Dielectric Material JESD-609 Code Feature Reference Standard Terminal Pitch Subcategory Pitch Body Material Connector Type A Connector Type B Insulation Material Contact Form Body Breadth Gender Type A Gender Type B Number of Rows Wire Gauge Wire Gauge (Max) Wire Gauge (Min) Current Rating (Amps) Includes Insulation Shell Material Plating Contact Finish Reliability Number Of PCB Rows PCB Contact Pattern Body Depth Mating Contact Pitch PCB Contact Row Spacing Shell Finish Rated Current (Signal) Dielectric Withstanding Voltage UL Flammability Code Number of Power Positions Contact Finish Thickness Material Flammability Rating Convert From (Adapter End) Convert To (Adapter End) Connector Style Contact Type Flange Feature Shell Size, Connector Layout Shell Material, Finish Backset Spacing Contact Termination Note
195-044-113L551 195-044-113L551 NorComp
RFQ

Min: 1

Mult: 1

download 195 Through Hole Panel Mount, Through Hole -55°C~125°C Tray Not Applicable Solder 500V ROHS3 Compliant 2009 /files/norcompinc-195015113l001-datasheets-7119.pdf 2A 53mm 13.1mm 12.5mm Black Lead Free 14 Weeks Plug, Male Pins 44 Male UL94 V-0 Brass PBT Polybutylene Terephthalate (PBT) Grounding Indents, Shielded Polyester Stamped 3 Insulated Steel Nickel Gold Flash UL94 V-0 D-Sub, High Density Signal Housing/Shell (4-40) 3 DB B High Density Steel, Nickel Plated
189-025-513R491 189-025-513R491 NorComp
RFQ

Min: 1

Mult: 1

download 189 Edge, Through Hole Panel Mount, Through Hole, Right Angle -55°C~105°C Tray Solder ROHS3 Compliant 2010 /files/norcompinc-189009513r491-datasheets-9590.pdf 5A Black Lead Free 14 Weeks No SVHC Receptacle, Female Sockets 25, 25 Female to Female 25 2 EAR99 Brass Nylon 8536.69.40.30 Polyamide (PA9T), Nylon 9T Board Lock, Shielded Steel Stamped 2, 2 Nickel Gold Flash UL94 V-0 D-Sub - Stacked Signal Housing/Shell (4-40) 3 DB B ; 3 DB B Steel, Nickel Plated 0.318 (8.08mm)
172-037-112R051 172-037-112R051 NorComp
RFQ

Min: 1

Mult: 1

download 172, M Series Through Hole Panel Mount, Through Hole -50°C~100°C Tray 1 (Unlimited) Solder ROHS3 Compliant 2008 /files/norcompinc-172009112r031-datasheets-3064.pdf 5A Beige Lead Free 14 Weeks Plug, Male Pins 37 Male NO NO NO NO NO GENERAL PURPOSE NO EAR99 Brass PBT 37 8536.69.40.30 Polybutylene Terephthalate (PBT), Polyester Board Lock, Grounding Indents Machined 2 Gold TIN 94V-0 Flash UL94 V-0 D-Sub Signal Board Side (4-40) 4 DC C Steel, Tin Plated
179-025-613R481 179-025-613R481 NorComp
RFQ

Min: 1

Mult: 1

download 179 Through Hole Board Edge, Through Hole, Right Angle -55°C~105°C Tray Solder ROHS3 Compliant 2010 /files/norcompinc-179025613r481-datasheets-3527.pdf 5A Black 14 Weeks Plug, Male Pins 25, 25 Male to Male 25 2 Brass Nylon Polyamide (PA9T), Nylon 9T Grounding Indents, Shielded Stamped 2, 2 Steel Nickel Gold Flash UL94 V-0 D-Sub - Stacked Signal Mating Side, Female Screwlock (4-40) 3 DB B ; 3 DB B Steel, Nickel Plated 0.318 (8.08mm)
680M17W2103L201 680M17W2103L201 NorComp
RFQ

Min: 1

Mult: 1

download Power-D 680M Free Hanging Panel Mount -55°C~155°C Tray 1 (Unlimited) Solder Cup ROHS3 Compliant 2013 /files/norcompinc-684m13w6103l461-datasheets-2882.pdf 20A 10.8966mm Black 14 Weeks No SVHC yes Plug, Male Pins 17 (15 + 2 Power) Male 17 Copper Alloy PBT Polybutylene Terephthalate (PBT) Grounding Indents 2.77mm Steel Machined 2 5A 20A Insulated Nickel Gold Flash UL94 V-0 D-Sub, Combo Signal and Power Housing/Shell (Unthreaded) 3 DB B - 17W2 Steel, Nickel Plated
774-E15-213R141 774-E15-213R141 NorComp
RFQ

Min: 1

Mult: 1

download Seal-D 774-E Through Hole Panel Mount, Through Hole, Right Angle -50°C~100°C Tray 1 (Unlimited) Solder ROHS3 Compliant 2012 /files/norcompinc-780m44213r001-datasheets-2740.pdf 5A White 14 Weeks Dust Tight, IP67, Waterproof yes Receptacle, Female Sockets 15 Female Brass Nylon IP67 - Dust Tight, Waterproof Polyamide (PA6T), Nylon 6T Mounting Brackets Machined 2 Gold Flash UL94 V-0 D-Sub Signal Mating Side, Female Screwlock (4-40) 2 DA A Steel, Nickel Plated 0.370 (9.40mm)
681S5W1203L001 681S5W1203L001 NorComp
RFQ

Min: 1

Mult: 1

download Seal-D 681S Free Hanging Panel Mount, Through Hole -55°C~155°C Tray 1 (Unlimited) Solder ROHS3 Compliant 2011 /files/norcompinc-780m44213r001-datasheets-2740.pdf 5A Black 14 Weeks Dust Tight, IP67, Waterproof No SVHC yes Receptacle, Female Sockets 5 (4 + 1 Power) Receptacle 5 Copper Alloy PBT IP67 - Dust Tight, Waterproof Polybutylene Terephthalate (PBT) Steel 2 5A 20/40A Insulated Nickel Gold 1 Flash UL94 V-0 D-Sub, Combo Signal and Power Housing/Shell (Unthreaded) 1 DE E - 5W1 Steel, Nickel Plated
681M5W1103L001 681M5W1103L001 NorComp
RFQ

Min: 1

Mult: 1

download Power-D 681M Through Hole Panel Mount, Through Hole -55°C~125°C Tray 1 (Unlimited) Solder ROHS3 Compliant 2013 /files/norcompinc-684m13w6103l461-datasheets-2882.pdf 40A 11mm Black 14 Weeks No SVHC yes Plug, Male Pins 5 (4 + 1 Power) Male 5 Copper Alloy PBT Polybutylene Terephthalate (PBT) Grounding Indents Steel Machined 2 5A 40A Insulated Nickel Gold 1 Flash UL94 V-0 D-Sub, Combo Signal and Power Housing/Shell (Unthreaded) 1 DE E - 5W1 Steel, Nickel Plated
680S21W1103L401 680S21W1103L401 NorComp
RFQ

Min: 1

Mult: 1

download Seal-D 680S Panel Mount -55°C~155°C Tray 1 (Unlimited) Solder Cup ROHS3 Compliant 2012 /files/norcompinc-780m44213r001-datasheets-2740.pdf 5A Black 14 Weeks Dust Tight, IP67, Waterproof No SVHC yes Plug, Male Pins 21 (20 + 1 Power) Male 21 Copper Alloy IP67 - Dust Tight, Waterproof Polybutylene Terephthalate (PBT), Glass Filled Grounding Indents Steel PBT 2 5A 40A Insulated Nickel Gold 1 Flash UL94 V-0 D-Sub, Combo Signal and Power Housing/Shell (Unthreaded) 3 DB B - 21W1 Steel, Nickel Plated
184A025-192L001 184A025-192L001 NorComp
RFQ

Min: 1

Mult: 1

download 184A Free Hanging Panel Mount -55°C~125°C Tray 1 (Unlimited) IDC, Ribbon Cable ROHS3 Compliant 2006 /files/norcompinc-184a009192l001-datasheets-2720.pdf 1.5A Black 14 Weeks No SVHC yes Plug, Male Pins 25 Male Copper Alloy Glass Polyester, Glass Filled Feed Through, Grounding Indents, Strain Relief Steel 2 28 AWG, Stranded Gold Flash UL94 V-0 D-Sub Signal Housing/Shell (Unthreaded) 3 DB B Steel, Tin Plated
179-025-613R571 179-025-613R571 NorComp
RFQ

Min: 1

Mult: 1

download 179 Through Hole Board Edge, Through Hole, Right Angle -55°C~105°C Tray Not Applicable Solder ROHS3 Compliant 2009 /files/norcompinc-179015613r571-datasheets-3551.pdf 5A 52.8mm 36.1mm 25.4mm Black Lead Free 14 Weeks 25 yes Plug, Male Pins 25, 25 Male UL94 V-0 Brass Nylon 50 Polyamide (PA9T), Nylon 9T e4 Board Lock, Grounding Indents, Shielded UL 2.7686mm D Type Connectors Polyamide Stamped 0.494 inch 2, 2 Insulated Steel Nickel Gold COMMERCIAL 2+2 STAGGERED 0.772 inch 0.109 inch 3.7338 mm 5A 1000VAC V Flash UL94 V-0 D-Sub - Stacked Signal Mating Side, Female Screwlock (4-40) 3 DB B ; 3 DB B Steel, Nickel Plated 0.318 (8.08mm)
180-M62-203L021 180-M62-203L021 NorComp
RFQ

Min: 1

Mult: 1

download 180-M, M Series Free Hanging, Panel Panel Mount -55°C~125°C Tray 1 (Unlimited) Solder Cup ROHS3 Compliant 2013 /files/norcompinc-180m15203l001-datasheets-6496.pdf 5A Black 14 Weeks Receptacle, Female Sockets 62 Male Copper Alloy PBT Polybutylene Terephthalate (PBT), Glass Filled Shielded 2.39mm Machined 3 24-28 AWG 3A Brass Nickel Gold Flash UL94 V-0 D-Sub, High Density Signal Cable Side (4-40) 4 DC C High Density Steel, Nickel Plated
184A025-292L011 184A025-292L011 NorComp
RFQ

Min: 1

Mult: 1

download 184A Free Hanging Panel Mount -55°C~125°C Tray 1 (Unlimited) IDC, Ribbon Cable ROHS3 Compliant 2011 /files/norcompinc-184a015292l001-datasheets-2836.pdf 1.5A Black 14 Weeks yes Receptacle, Female Sockets 25 Female Copper Alloy Glass Polyester, Glass Filled Feed Through, Strain Relief 2 28 AWG, Stranded Gold Flash UL94 V-0 D-Sub Signal Cable Side (4-40) 3 DB B Steel, Tin Plated
182-015-113R481 182-015-113R481 NorComp
RFQ

Min: 1

Mult: 1

download 182 Through Hole Panel Mount, Through Hole, Right Angle -55°C~105°C Tray Solder ROHS3 Compliant 2008 /files/norcompinc-182037113r161-datasheets-3788.pdf 5A 39.1mm 12.5mm 24.9mm Black Lead Free 12 Weeks yes Plug, Male Pins 15 Male NO NO NO NO NO GENERAL PURPOSE NO UL94 V-0 Brass Nylon 15 Polyamide (PA9T), Nylon 9T Grounding Indents 2 Gold 94V-0 Flash UL94 V-0 D-Sub Signal Mating Side, Female Screwlock (4-40) 2 DA A Steel, Nickel Plated 0.318 (8.08mm)
382-009-112L565 382-009-112L565 NorComp
RFQ

Min: 1

Mult: 1

download Micro-D 382 Panel, Through Hole Board Edge, Through Hole, Right Angle -55°C~85°C Tube 1 (Unlimited) Solder RoHS Compliant 2011 /files/norcompinc-382009112l565-datasheets-3866.pdf 1A 12 Weeks No SVHC yes Plug, Male Pins 9, 9 Male to Male NO NO NO NO NO GENERAL PURPOSE 18 MULTIPLE MATING PARTS AVAILABLE NO 2 EAR99 OTHER STACKING CONNECTOR: 9 CONTACTS, 1/E SHELL SIZE Copper Alloy 8536.69.40.30 Board Lock, Shielded 1.27mm Steel Thermoplastic 2, 2 Insulated Copper, Tin Gold TIN 94V-0 15.0μin 0.38μm UL94 V-0 D-Type, Micro-D - Stacked Signal Mating Side, Female Screwlock (2-56) 0.050 Pitch x 0.043 Row to Row Steel, Tin Plated
671-015-113R021 671-015-113R021 NorComp
RFQ

Min: 1

Mult: 1

download Seal-D 671 Through Hole Panel Mount, Through Hole -50°C~100°C Tray 1 (Unlimited) Solder RoHS Compliant 2012 /files/norcompinc-780m44213r001-datasheets-2740.pdf 5A Black 12 Weeks Dust Tight, IP66, Water Resistant yes Plug, Male Pins 15 Brass Nylon IP66 - Dust Tight, Water Resistant Polyamide (PA9T), Nylon 9T Grounding Indents Stamped 2 Gold Flash UL94 V-0 D-Sub Signal Board Side (4-40) 2 DA A Steel, Nickel Plated
682-025-113R171 682-025-113R171 NorComp
RFQ

Min: 1

Mult: 1

download Seal-D 682 Through Hole Panel Mount, Through Hole, Right Angle -55°C~105°C Tray 1 (Unlimited) Solder RoHS Compliant 2012 /files/norcompinc-780m44213r001-datasheets-2740.pdf 5A Black 12 Weeks Dust Tight, IP66, Water Resistant yes Plug, Male Pins 25 Brass Nylon IP66 - Dust Tight, Water Resistant Polyamide (PA9T), Nylon 9T Ground Strap, Grounding Indents 2 Gold Flash UL94 V-0 D-Sub Signal Housing/Shell (4-40) 3 DB B Steel, Nickel Plated 0.318 (8.08mm)
680-015-113R051 680-015-113R051 NorComp
RFQ

Min: 1

Mult: 1

download Seal-D 680 Through Hole Panel Mount, Through Hole -50°C~100°C Tray 1 (Unlimited) Solder RoHS Compliant 2012 /files/norcompinc-780m44213r001-datasheets-2740.pdf 5A 12 Weeks Dust Tight, IP66, Water Resistant yes Plug, Male Pins 15 Brass PBT IP66 - Dust Tight, Water Resistant Polybutylene Terephthalate (PBT) Board Lock, Grounding Indents Stamped 3 Gold Flash UL94 V-0 D-Sub, High Density Signal Board Side (4-40) 1 DE E High Density Steel, Nickel Plated
681-015-113R531 681-015-113R531 NorComp
RFQ

Min: 1

Mult: 1

download Seal-D 681 Through Hole Panel Mount, Through Hole, Right Angle -50°C~100°C Tray 1 (Unlimited) Solder 500V RoHS Compliant 2012 /files/norcompinc-780m44213r001-datasheets-2740.pdf 2A Black Lead Free Metal 12 Weeks Dust Tight, IP66, Water Resistant yes Plug, Male Pins 15 Male Brass Nylon IP66 - Dust Tight, Water Resistant Polyamide (PA9T), Nylon 9T Board Lock, Grounding Indents Polyamide 3 Insulated Nickel Gold Flash UL94 V-0 D-Sub, High Density Signal Housing/Shell (4-40) 1 DE E High Density Steel, Nickel Plated 0.350 (8.89mm)
RJADK09S7080831 RJADK09S7080831 NorComp
RFQ

Min: 1

Mult: 1

download RJADK Bulk ROHS3 Compliant 2007 /files/norcompinc-rjadk09s7080811-datasheets-8305.pdf Gray 14 Weeks No SVHC 9 D-Sub, Standard RJ45 Female D-Sub, 9 Pin Female Modular, Female Jack, 8p8c (RJ45)
112-014-213-001 112-014-213-001 NorComp
RFQ

Min: 1

Mult: 1

download SCSI 112 Through Hole Through Hole, Right Angle Not Applicable Solder Non-RoHS Compliant 2002 /files/norcompinc-112014213001-datasheets-0092.pdf Contains Lead Receptacle 14 Female 14 Blue UL94 V-0 Gold Bail Lock 2 Gold Flash Outer Shroud Contacts Housing/Shell (4-40)
111-014-113-001 111-014-113-001 NorComp
RFQ

Min: 1

Mult: 1

download SCSI 111 Through Hole Through Hole Not Applicable Solder Non-RoHS Compliant 2002 /files/norcompinc-111024113001-datasheets-0120.pdf Contains Lead Plug 14 Male 14 Blue UL94 V-0 Gold Plastic 2 Gold Flash Center Strip Contacts
112-050-213R001 112-050-213R001 NorComp
RFQ

Min: 1

Mult: 1

download SCSI 112 Through Hole Through Hole, Right Angle Not Applicable Solder ROHS3 Compliant 2010 /files/norcompinc-112050213r001-datasheets-3326.pdf 5A Lead Free 14 Weeks No SVHC yes Receptacle 50 NO NO NO NO NO GENERAL PURPOSE FEMALE NO Blue UL94 V-0 EAR99 Brass, Bronze 50 8536.69.40.30 e3 Bail Lock POLYBUTYLENE TEREPHTHALATE 2 STEEL Gold NICKEL 94V-0 Flash Outer Shroud Contacts Housing/Shell (4-40)
112-036-213R491 112-036-213R491 NorComp
RFQ

Min: 1

Mult: 1

download SCSI 112 Through Hole Through Hole, Right Angle Solder ROHS3 Compliant 2014 /files/norcompinc-112036213r491-datasheets-9317.pdf 14 Weeks yes Receptacle 36 unknown Board Lock 2 Gold Flash Outer Shroud Contacts Housing/Shell (4-40)
110-024-103L001 110-024-103L001 NorComp
RFQ

Min: 1

Mult: 1

download SCSI Centronics, 110- Free Hanging Free Hanging (In-Line) Bulk 1 (Unlimited) Solder Cup RoHS Compliant 2008 /files/norcompinc-110036103l001-datasheets-2021.pdf 5A No SVHC Plug 24 Male NO NO NO NO NO GENERAL PURPOSE MULTIPLE MATING PARTS AVAILABLE NO EAR99 COPPER ALLOY 24 unknown 8536.69.40.30 Backshell, Bail Lock, Strain Relief GALSS FILLED THERMOPLASTIC 2 STEEL Gold NICKEL 94V-0 Flash Center Strip Contacts
164-096-001L000 164-096-001L000 NorComp
RFQ

Min: 1

Mult: 1

download Tray Not Applicable RoHS Compliant 2006 /files/norcompinc-164096001l000-datasheets-3426.pdf Lead Free 12 Weeks 96 Strain Relief
GCHDLP62M62F GCHDLP62M62F NorComp
RFQ

Min: 1

Mult: 1

download GCLP Free Hanging Panel Mount -55°C~105°C Not Applicable ROHS3 Compliant 2011 /files/norcompinc-gchdlp62m62f-datasheets-5365.pdf 14 Weeks No SVHC 62 Yellow D-Sub Male Female 3 3A 3 pcs - 1 Connector, 2 Jack Screws Gold Flash UL94 V-0 D-Sub, 62 HD, Male D-Sub, 62 HD, Female Connector Saver Steel, Tin Plated
180-001-170-001 180-001-170-001 NorComp
RFQ

Min: 1

Mult: 1

download Signal 180 Tape & Reel (TR) Not Applicable Crimp Non-RoHS Compliant 2002 /files/norcompinc-180001170001-datasheets-7044.pdf Contains Lead Male Pin Male Brass Gold High Density (HD), Insulation Support Machined 22-26 AWG 26 AWG 22 AWG Gold Flash Male Pin Crimp
170-101-170L001 170-101-170L001 NorComp
RFQ

Min: 1

Mult: 1

download Signal 170 Bulk Not Applicable ROHS3 Compliant 2009 /files/norcompinc-170101170l002-datasheets-8756.pdf 5A Lead Free 14 Weeks No SVHC yes Male Pin Male Brass 24 AWG Insulation Support Stamped 24-28 AWG 28 AWG 24 AWG Gold Flash Male Pin Crimp
180-078-273L020 180-078-273L020 NorComp
RFQ

Min: 1

Mult: 1

download 180 Free Hanging Free Hanging (In-Line) -50°C~100°C Tray Crimp ROHS3 Compliant 2008 /files/norcompinc-180078273l020-datasheets-1428.pdf 2A 67mm 15.4mm 500V Lead Free 14 Weeks yes Receptacle for Female Contacts 78 Female NO NO NO NO NO GENERAL PURPOSE YES BRASS 78 e4 GLASS FILLED POLYBUTYLENE TEREPHTHALATE/NYLON66 4 Nickel D-Sub, High Density Signal Cable Side (4-40) 5 DD D High Density Steel, Nickel Plated Contacts Not Included

In Stock

Please send RFQ , we will respond immediately.