NBPDANN150PAUNV

NBPDANN150PAUNV datasheet pdf and Pressure Sensors, Transducers product details from Honeywell Sensing and Productivity Solutions stock available at Feilidi


  • Manufacturer: Honeywell Sensing and Productivity Solutions
  • NO: 384-NBPDANN150PAUNV
  • Package: 4-DIP (0.453, 11.50mm), Top Port
  • Datasheet: pdf
  • Stock: 2843
  • Description: NBPDANN150PAUNV datasheet pdf and Pressure Sensors, Transducers product details from Honeywell Sensing and Productivity Solutions stock available at Feilidi(Kg)

Quantity:


  • Delivery: Delivery
  • Payment: payment

In Stock

Please send RFQ , we will respond immediately.

authentication (1) authentication (2) authentication (3) authentication (4) authentication (5) authentication (6) authentication (7) authentication (8) authentication (9)

Purchase & Inquiry

Transport

User guide

Purchase

You may place an order without registering to Chip Smart.
We strongly suggest you sign in before purchasing as you can track your order in real time.

Means of Payment

For your convenience, we accept multiple payment methods in USD, including PayPal, Credit Card, and wire transfer.

RFQ (Request for Quotations)

It is recommended to request for quotations to get the latest prices and inventories about the part.
Our sales will reply to your request by email within 24 hours.

IMPORTANT NOTICE

1. You'll receive an order information email in your inbox. (Please remember to check the spam folder if you didn't hear from us).
2. Since inventories and prices may fluctuate to some extent, the sales manager is going to reconfirm the order and let you know if there are any updates.

Shipping Cost

Shipping starts at $40, but some countries will exceed $40. For example (South Africa, Brazil, India, Pakistan, Israel, etc.)
The basic freight (for package ≤0.5kg or corresponding volume) depends on the time zone and country.

Shipping Method

Currently, our products are shipped through DHL, FedEx, SF, and UPS.

Delivery Time

Once the goods are shipped, estimated delivery time depends on the shipping methods you chose:

FedEx International, 5-7 business days.

The following are some common countries' logistic time.transport

SPECIFICATIONS

Parameters
Termination Style PC Pin
Output Type Wheatstone Bridge
Max Supply Voltage 12V
Min Supply Voltage 1.8V
Operating Supply Current 1.5mA
Nominal Supply Current 1.5mA
Accuracy ±0.25%
Operating Pressure 150PSI (1034.21kPa)
Pressure Type Absolute
Port Style Barbed
Port Size Male - 0.08 1.91mm Tube
Maximum Pressure 240PSI (1654.74kPa)
Max Pressure 240 PSI
Height 10.94mm
Length 7mm
Width 11.5mm
Radiation Hardening No
REACH SVHC No SVHC
RoHS Status RoHS Compliant
Factory Lead Time 10 Weeks
Mount Through Hole
Package / Case 4-DIP (0.453, 11.50mm), Top Port
Number of Pins 4
Operating Temperature -40°C~125°C
Published 2007
Series NBP
Part Status Active
Moisture Sensitivity Level (MSL) 1 (Unlimited)
Termination PC Pin
Resistance 3kOhm
Max Operating Temperature 125°C
Min Operating Temperature -40°C
Applications Board Mount
Voltage - Rated DC 5V
Voltage - Supply 1.8V~12V
Output 0 mV ~ 130 mV (5V)

NBPDANN150PAUNV Overview


In order to make your life easier, a 4-DIP (0.453, 11.50mm), Top Port package includes this transducer. For reliable operation, the transducers should be set at -40°C~125°C. Obtaining a 1.8V~12V supply voltage is not a problem for the transducers. It is possible for the transducers to operate at a maximum operating temperature of 125°C. There can be no temperature below -40°C in which the transducers operate. A connection of the 4 pins is required to make the transducers operate correctly. In normal conditions, the transducers can operate with a nominal supply current of 1.5mA. For the transducers to operate continuously at ambient temperatures, the DC voltage should be set to 5V. A voltage of 12V is the maximum voltage that can be applied to a transducer without damaging it. A minimum supply voltage of 1.8V will work for the transducers.

NBPDANN150PAUNV Features


Moisture Sensitivity Level: 1 (Unlimited)
Package / Case: 4-DIP (0.453, 11.50mm), Top Port
Operating Temperature: -40°C~125°C
4 Pins
NBP series
Operating Pressure: 150PSI (1034.21kPa)

NBPDANN150PAUNV Applications


There are a lot of Honeywell Sensing and Productivity Solutions NBPDANN150PAUNV Transducers applications.

  • Outdoor navigation, leisure and sports applications
  • Bike computers
  • Home appliance
  • Hydrogen Storage
  • Refrigerant pressure monitoring in HVAC/R systems
  • Health care applications (e.g. spirometry)
  • Hydraulic, brake, and engine oil fluid pressure monitoring
  • Automotive applications (barometric air pressure measurement)
  • Enhancement of GPS navigation
  • Dry air system pressure, process controls and automation

In Stock