Cantherm(1408)

Compare Image Name Manufacturer Pricing(USD) Quantity Weight(Kg) Size(LxWxH) Part Status Type Series Mount Mounting Type Operating Temperature Packaging Moisture Sensitivity Level (MSL) Termination Max Operating Temperature Min Operating Temperature RoHS Status Published Datasheet Diameter Package / Case Height Lead Free Number of Terminations Factory Lead Time Approval Agency Resistance Lead Pitch Pbfree Code Thickness Lead Length Terminal Shape Tolerance Surface Mount Max Power Dissipation Operating Temperature (Max) Operating Temperature (Min) Lead Spacing Termination Style Circuit Throw Configuration Mounting Feature Terminal Placement Resistor Type Power - Max Power Dissipation-Max Resistance Tolerance Thermistor Application R @ 25°C Current - Steady State Max R @ Current Resistance in Ω @ 25°C B Value Tolerance B25/50 Switching Cycles Current Rating - AC Switching Temperature Reset Temperature Current Rating - DC
MF11-0200005 MF11-0200005 Cantherm
RFQ

Min: 1

Mult: 1

download MF11 PCB, Through Hole Through Hole -55°C~125°C Bulk Not Applicable 125°C -55°C ROHS3 Compliant https://pdf.utmel.com/r/datasheets/cantherm-mf110002010-datasheets-0680.pdf Disc, 6.5mm Dia x 5.0mm W 8 Weeks 2kOhm 5% 500mW 500mW ±5% 2k ±5% 3950K
MF52A1104G4150 MF52A1104G4150 Cantherm
RFQ

Min: 1

Mult: 1

download MF52 Through Hole Through Hole -55°C~125°C Bulk Not Applicable 125°C -55°C ROHS3 Compliant /files/cantherm-mf52a2103j3470-datasheets-5532.pdf Bead 8 Weeks 2% 50mW 50mW ±2% 100k ±1% 4150K
CWF3AA202F3470 CWF3AA202F3470 Cantherm
RFQ

Min: 1

Mult: 1

download CWF3 Free Hanging Free Hanging -55°C~125°C Not Applicable ROHS3 Compliant 2010 /files/cantherm-cwf1b103g3380-datasheets-5980.pdf Cylindrical Probe, Plastic 9 Weeks 7.87 200.00mm 1% ±1% 2k ±2% 3470K
MF52C153F3470-G410 MF52C153F3470-G410 Cantherm
RFQ

Min: 1

Mult: 1

download MF52 Through Hole Through Hole -55°C~125°C Bulk Not Applicable ROHS3 Compliant /files/cantherm-mf52a2103j3470-datasheets-5532.pdf Bead 9 Weeks 7.87 200.00mm 1% 50mW ±1% 15k 3470K
MF58204F3950 MF58204F3950 Cantherm
RFQ

Min: 1

Mult: 1

download MF58 Through Hole Through Hole -55°C~200°C Bulk Not Applicable ROHS3 Compliant /files/cantherm-mf58104f3950-datasheets-5255.pdf Bead, Glass 9 Weeks 1% 50mW ±1% 220k 4150K
MF52F503F3950 MF52F503F3950 Cantherm
RFQ

Min: 1

Mult: 1

download MF52 Through Hole Through Hole -55°C~125°C Bulk Not Applicable 125°C -55°C ROHS3 Compliant 2010 /files/cantherm-mf52a2103j3470-datasheets-5532.pdf Bead 9 Weeks 1% 50mW 50mW ±1% 50k ±1% 3950K
MF52C1333F3470 MF52C1333F3470 Cantherm
RFQ

Min: 1

Mult: 1

download MF52 Through Hole Through Hole -55°C~125°C Bulk Not Applicable ROHS3 Compliant 2010 /files/cantherm-mf52a2103j3470-datasheets-5532.pdf Bead 9 Weeks 7.87 200.00mm 1% 50mW ±1% 33k 3470K
MF51B103F3380 MF51B103F3380 Cantherm
RFQ

Min: 1

Mult: 1

download MF51B Through Hole Through Hole -20°C~250°C Bulk Not Applicable 250°C -20°C RoHS Compliant 2006 /files/cantherm-mf58104f3950-datasheets-5255.pdf Bead, Glass 1% ±1% 10k
CS701525Z CS701525Z Cantherm
RFQ

Min: 1

Mult: 1

download R53 Chassis Mount Chassis Mount 1 (Unlimited) ROHS3 Compliant 2010 /files/cantherm-cs706525z-datasheets-8425.pdf Cylinder with Mounting Flange 11 Weeks ±9°F ±5°C Quick Connect SPST-NC 100K 10A 250V 15A 125V 59°F 15°C 10A 24V 15A 12V
CS708015Z CS708015Z Cantherm
RFQ

Min: 1

Mult: 1

download R53 Chassis Mount Chassis Mount 1 (Unlimited) ROHS3 Compliant 2010 /files/cantherm-cs706525z-datasheets-8425.pdf Cylinder with Mounting Flange 11 Weeks ±9°F ±5°C Quick Connect SPST-NO 100K 10A 250V 15A 125V 176°F 80°C 10A 24V 15A 12V
F20A155053600060 F20A155053600060 Cantherm
RFQ

Min: 1

Mult: 1

download F20 Through Hole Through Hole Not Applicable ROHS3 Compliant 2009 /files/cantherm-f20b090053600060-datasheets-6670.pdf 2-SIP, Potted 5 Weeks ±9°F ±5°C Wire Leads - 4 (101.6mm) SPST-NC 7K 1.6A 250V 311°F 155°C 257°F 125°C
F20B11005ACFA06E F20B11005ACFA06E Cantherm
RFQ

Min: 1

Mult: 1

download F20 Through Hole Through Hole Not Applicable ROHS3 Compliant 2009 /files/cantherm-f20b090053600060-datasheets-6670.pdf Potted - Wire Leads 5 Weeks ±9°F ±5°C Wire Leads - 6 (152.4mm) SPST-NO 7K 1.6A 250V 230°F 110°C 176°F 80°C
F20B140053600060 F20B140053600060 Cantherm
RFQ

Min: 1

Mult: 1

download F20 Through Hole Through Hole Not Applicable ROHS3 Compliant 2009 /files/cantherm-f20b090053600060-datasheets-6670.pdf 2-SIP, Potted 5 Weeks ±9°F ±5°C Wire Leads - 4 (101.6mm) SPST-NO 7K 1.6A 250V 284°F 140°C 230°F 110°C
B12B13005AEDA0GE B12B13005AEDA0GE Cantherm
RFQ

Min: 1

Mult: 1

download B12 Through Hole Through Hole Not Applicable Wire Leads ROHS3 Compliant /files/cantherm-b12a11525aefa0ge-datasheets-6629.pdf Radial 5 Weeks ±9°F ±5°C Wire Leads - 4 (101.6mm) SPST-NO SPST 5K 1.6A 250V 266°F 130°C 212°F 100°C
F20B08005ACFA20E F20B08005ACFA20E Cantherm
RFQ

Min: 1

Mult: 1

download Mechanical F20 Through Hole Through Hole Not Applicable Wire Leads ROHS3 Compliant 2009 /files/cantherm-f20b090053600060-datasheets-6670.pdf 2-SIP, Potted 5 Weeks ±9°F ±5°C Wire Leads - 6 (152.4mm) SPST-NO SPST 7K 1.6A 250V 176°F 80°C 122°F 50°C
B12B13505AEDA0GE B12B13505AEDA0GE Cantherm
RFQ

Min: 1

Mult: 1

download B12 Through Hole Through Hole Not Applicable Wire Leads ROHS3 Compliant /files/cantherm-b12a11525aefa0ge-datasheets-6629.pdf Radial 5 Weeks ±9°F ±5°C Wire Leads - 4 (101.6mm) SPST-NO SPST 5K 1.6A 250V 275°F 135°C 221°F 105°C
F20A070051ZA0060 F20A070051ZA0060 Cantherm
RFQ

Min: 1

Mult: 1

download F20 Through Hole Through Hole Not Applicable ROHS3 Compliant /files/cantherm-f20b090053600060-datasheets-6670.pdf 2-SIP, Potted 5 Weeks ±9°F ±5°C Wire Leads - 4 (101.6mm) SPST-NC 7K 1.6A 250V 158°F 70°C 104°F 40°C
F20A085053600060 F20A085053600060 Cantherm
RFQ

Min: 1

Mult: 1

download F20 Through Hole Through Hole Not Applicable ROHS3 Compliant /files/cantherm-f20b090053600060-datasheets-6670.pdf 2-SIP, Potted 5 Weeks ±9°F ±5°C Wire Leads - 4 (101.6mm) SPST-NC 7K 1.6A 250V 185°F 85°C 131°F 55°C
CS712025Y CS712025Y Cantherm
RFQ

Min: 1

Mult: 1

download R53 Chassis Mount Chassis Mount 1 (Unlimited) ROHS3 Compliant /files/cantherm-cs706525z-datasheets-8425.pdf Cylinder with Mounting Flange 11 Weeks ±9°F ±5°C Quick Connect SPST-NC 100K 10A 250V 15A 125V 248°F 120°C 10A 24V 15A 12V
CS701525Y CS701525Y Cantherm
RFQ

Min: 1

Mult: 1

download R53 Chassis Mount Chassis Mount 1 (Unlimited) ROHS3 Compliant 2010 /files/cantherm-cs706525z-datasheets-8425.pdf Cylinder with Mounting Flange 11 Weeks ±9°F ±5°C Quick Connect SPST-NC 100K 10A 250V 15A 125V 59°F 15°C 10A 24V 15A 12V
F20A110053600060 F20A110053600060 Cantherm
RFQ

Min: 1

Mult: 1

download F20 Through Hole Through Hole Not Applicable ROHS3 Compliant 2009 /files/cantherm-f20b090053600060-datasheets-6670.pdf 2-SIP, Potted 5 Weeks ±9°F ±5°C Wire Leads - 4 (101.6mm) SPST-NC 7K 1.6A 250V 230°F 110°C 176°F 80°C
B12B08005AEDA0GE B12B08005AEDA0GE Cantherm
RFQ

Min: 1

Mult: 1

download B12 Through Hole Through Hole Not Applicable Wire Leads ROHS3 Compliant /files/cantherm-b12a11525aefa0ge-datasheets-6629.pdf Radial 5 Weeks ±9°F ±5°C Wire Leads - 4 (101.6mm) SPST-NO SPST 5K 1.6A 250V 176°F 80°C 122°F 50°C
T22A08505DFFBG0E T22A08505DFFBG0E Cantherm
RFQ

Min: 1

Mult: 1

download T22 Through Hole Through Hole 1 (Unlimited) ROHS3 Compliant /files/cantherm-t22a13005dffbg0e-datasheets-8609.pdf Shrink Cap, Potted - Wire Leads 5 Weeks ±9°F ±5°C Wire Leads - 4 (101.6mm) SPST-NC 10K 3A 250V 185°F 85°C 131°F 55°C
MQT8K 060XB2, 950L MQT8K 060XB2, 950L Cantherm
RFQ

Min: 1

Mult: 1

download Not Applicable ROHS3 Compliant 7 Weeks
TS3-85B3 TS3-85B3 Cantherm
RFQ

Min: 1

Mult: 1

download MOXIE® Through Hole Through Hole -40°C~200°C Bulk 1 (Unlimited) 200°C -40°C RoHS Compliant /files/cantherm-ts385b3-datasheets-4295.pdf 4.75mm TO-51-2 Variant 4.11mm Lead Free 0.02 0.53mm
MF52A152J3470 MF52A152J3470 Cantherm
RFQ

Min: 1

Mult: 1

Through Hole Bulk 125°C -55°C RoHS Compliant Lead Free 1.5kOhm 5% 50mW
MF72-016D7 MF72-016D7 Cantherm
RFQ

Min: 1

Mult: 1

download MF72 Bulk Not Applicable ROHS3 Compliant 2006 /files/cantherm-mf72005d9-datasheets-0033.pdf 0.354 9.00mm Lead Free 2 10 Weeks UL 16Ohm 5.0038mm yes 5mm WIRE ±20% NO 200°C -55°C 0.197 5.00mm THROUGH HOLE MOUNT RADIAL NTC THERMISTOR OVERLOAD PROTECTION 16 Ω 700mA 1.003 Ω
MF72-060D5 MF72-060D5 Cantherm
RFQ

Min: 1

Mult: 1

download MF72 Bulk Not Applicable ROHS3 Compliant /files/cantherm-mf72005d9-datasheets-0033.pdf 0.276 7.00mm Lead Free 10 Weeks UL 60Ohm 5.0038mm 5mm ±20% 0.098 2.50mm 60 Ohms 300mA 1.878 Ohms
MF72-022D11 MF72-022D11 Cantherm
RFQ

Min: 1

Mult: 1

download MF72 Bulk Not Applicable ROHS3 Compliant 2006 /files/cantherm-mf72005d9-datasheets-0033.pdf 0.512 13.00mm Lead Free 10 Weeks UL 22Ohm 7.493mm 5.5mm ±20% 0.295 7.50mm 22 Ohms 2A 563 mOhms
MF72-000.7D25 MF72-000.7D25 Cantherm
RFQ

Min: 1

Mult: 1

download MF72 Bulk Not Applicable ROHS3 Compliant /files/cantherm-mf72005d9-datasheets-0033.pdf 1.083 27.50mm Lead Free 10 Weeks UL 700mOhm 10.0076mm 8mm ±20% 0.394 10.00mm 700 mOhms 12A 14 mOhms

In Stock