Compare | Image | Name | Manufacturer | Pricing(USD) | Quantity | Weight(Kg) | Size(LxWxH) | Part Status | Type | Series | Mount | Mounting Type | Operating Temperature | Packaging | Moisture Sensitivity Level (MSL) | Termination | Max Operating Temperature | Min Operating Temperature | Voltage - Rated | RoHS Status | Published | Datasheet | Current Rating | Package / Case | Length | Height | Width | Voltage - Rated AC | Color | Lead Free | Material | Factory Lead Time | Ratings | REACH SVHC | Number of Pins | Accessory Type | Pbfree Code | Connector Type | Number of Positions | Gender | MIL Conformance | DIN Conformance | IEC Conformance | Filter Feature | Mixed Contacts | Option | Number of Contacts | Mating Information | Contact Gender | Empty Shell | Housing Color | Number of Ports | Flammability Rating | ECCN Code | Additional Feature | Contact Material | Contact Plating | Housing Material | Total Number of Contacts | Reach Compliance Code | Ingress Protection | HTS Code | Wire/Cable Gauge | Dielectric Material | JESD-609 Code | Feature | Pitch | Body Material | Connector Type A | Connector Type B | Insulation Material | Assembly Item Name | Contact Form | Length - Termination | Gender Type A | Gender Type B | Number of Rows | Wire Gauge | Wire Gauge (Max) | Wire Gauge (Min) | Current Rating (Amps) | Includes | Insulation | Shell Material | Plating | Contact Finish | Shell Finish | UL Flammability Code | Number of Power Positions | Contact Finish Thickness | Material Flammability Rating | Convert From (Adapter End) | Convert To (Adapter End) | Connector Style | Contact Type | Flange Feature | Shell Size, Connector Layout | Shell Material, Finish | Backset Spacing | Shell Size - Insert | Contact Termination | Note | Termination Finish |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
681M3W3K203L001 | NorComp |
Min: 1 Mult: 1 |
download | Power-D 681M | Through Hole | Panel Mount, Through Hole | -55°C~125°C | Tray | 1 (Unlimited) | Solder | ROHS3 Compliant | 2013 | /files/norcompinc-684m13w6103l461-datasheets-2882.pdf | 40A | 10.7mm | 14 Weeks | No SVHC | yes | Receptacle, Female Sockets | 3 (Power) | Receptacle | 3 | Brass | PBT | Polybutylene Terephthalate (PBT) | Steel | Machined | 1 | Insulated | Nickel | Gold | Flash | UL94 V-0 | D-Sub, Combo | Power | Housing/Shell (Unthreaded) | 2 DA A - 3W3 | Steel, Nickel Plated | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
681M13W3103L001 | NorComp |
Min: 1 Mult: 1 |
download | Power-D 681M | Through Hole | Panel Mount, Through Hole | -55°C~155°C | Tray | 1 (Unlimited) | Solder | ROHS3 Compliant | 2011 | /files/norcompinc-684m13w6103l461-datasheets-2882.pdf | 5A | 10.9mm | Black | 14 Weeks | No SVHC | yes | Plug, Male Pins | 13 (10 + 3 Power) | Male | 13 | Copper Alloy | PBT | Polybutylene Terephthalate (PBT) | Grounding Indents | 2.77mm | Steel | Machined | 2 | 5A 40A | Insulated | Nickel | Gold | 3 | Flash | UL94 V-0 | D-Sub, Combo | Signal and Power | Housing/Shell (Unthreaded) | 3 DB B - 13C3 13W3 | Steel, Nickel Plated | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
179-037-413R691 | NorComp |
Min: 1 Mult: 1 |
download | 179 | Through Hole | Board Edge, Through Hole, Right Angle | -55°C~105°C | Tray | Solder | ROHS3 Compliant | 2010 | /files/norcompinc-179009413r691-datasheets-5881.pdf | 5A | Black | 14 Weeks | Plug, Male Pins; Receptacle, Female Sockets | 37, 37 | Male to Female | 37 | 2 | Brass | Nylon | Polyamide (PA9T), Nylon 9T | e4 | Board Lock, Grounding Indents, Shielded | Stamped | 2, 2 | Steel | Nickel | Gold | Flash | UL94 V-0 | D-Sub - Stacked | Signal | Housing/Shell (4-40) | 4 DC C ; 4 DC C | Steel, Nickel Plated | 0.318 (8.08mm) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
681S11W1103L001 | NorComp |
Min: 1 Mult: 1 |
download | Seal-D 681S | Through Hole | Panel Mount, Through Hole | -55°C~155°C | Tray | 1 (Unlimited) | Solder | ROHS3 Compliant | 2011 | /files/norcompinc-780m44213r001-datasheets-2740.pdf | 5A | Black | 14 Weeks | Dust Tight, IP67, Waterproof | No SVHC | yes | Plug, Male Pins | 11 (10 + 1 Power) | Male | 11 | Copper Alloy | PBT | IP67 - Dust Tight, Waterproof | Polybutylene Terephthalate (PBT) | Grounding Indents | Steel | 2 | 5A 40A | Insulated | Nickel | Gold | 1 | Flash | UL94 V-0 | D-Sub, Combo | Signal and Power | Housing/Shell (Unthreaded) | 2 DA A - 11C1 11W1 | Steel, Nickel Plated | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
172-050-202R011 | NorComp |
Min: 1 Mult: 1 |
download | 172, M Series | Free Hanging, Panel | Panel Mount | -50°C~100°C | Tray | Not Applicable | Solder Cup | ROHS3 Compliant | 2008 | /files/norcompinc-172009202r011-datasheets-5641.pdf | 5A | 67mm | 10.2mm | 15.4mm | Beige | Lead Free | 12 Weeks | yes | Receptacle, Female Sockets | 50 | Female | UL94 V-0 | Brass | PBT | unknown | Polybutylene Terephthalate (PBT), Glass Filled | Machined | 3 | 20-26 AWG | Gold | Flash | UL94 V-0 | D-Sub | Signal | Cable Side (4-40) | 5 DD D | Steel, Tin Plated | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
681S21W1103L001 | NorComp |
Min: 1 Mult: 1 |
download | Seal-D 681S | Free Hanging | Panel Mount, Through Hole | -55°C~155°C | Tray | 1 (Unlimited) | Solder | ROHS3 Compliant | 2011 | /files/norcompinc-780m44213r001-datasheets-2740.pdf | 5A | Black | 14 Weeks | Dust Tight, IP67, Waterproof | No SVHC | yes | Plug, Male Pins | 21 (20 + 1 Power) | Male | 21 | Copper Alloy | PBT | IP67 - Dust Tight, Waterproof | Polybutylene Terephthalate (PBT) | Grounding Indents | Steel | 2 | 5A 40A | Insulated | Nickel | Gold | 1 | Flash | UL94 V-0 | D-Sub, Combo | Signal and Power | Housing/Shell (Unthreaded) | 3 DB B - 21W1 | Steel, Nickel Plated | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
184A015-192L011 | NorComp |
Min: 1 Mult: 1 |
download | 184A | Free Hanging | Panel Mount | -55°C~125°C | Tray | 1 (Unlimited) | IDC, Ribbon Cable | ROHS3 Compliant | 2011 | /files/norcompinc-184a009192l001-datasheets-2720.pdf | 1.5A | Black | 14 Weeks | yes | Plug, Male Pins | 15 | Male | Copper Alloy | Glass | Polyester, Glass Filled | Feed Through, Grounding Indents, Strain Relief | 2 | 28 AWG, Stranded | Gold | Flash | UL94 V-0 | D-Sub | Signal | Cable Side (4-40) | 2 DA A | Steel, Tin Plated | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
172-050-242R011 | NorComp |
Min: 1 Mult: 1 |
download | 172, M Series | Through Hole | Panel Mount, Through Hole | -50°C~100°C | Tray | Not Applicable | Wire Wrap | ROHS3 Compliant | 2009 | /files/norcompinc-172009242r011-datasheets-6223.pdf | 5A | 52.8mm | 10.1mm | 15.3mm | Beige | Lead Free | 10 Weeks | yes | Receptacle, Female Sockets | 50 | Female | NO | NO | NO | NO | NO | GENERAL PURPOSE | NO | UL94 V-0 | EAR99 | Brass | PBT | 50 | Polybutylene Terephthalate (PBT), Polyester | Machined | 3 | Tin | Gold | TIN | 94V-0 | Flash | UL94 V-0 | D-Sub | Signal | Board Side (4-40) | 5 DD D | Steel, Tin Plated | |||||||||||||||||||||||||||||||||||||||||||||||||||||
681S21WA4PL001 | NorComp |
Min: 1 Mult: 1 |
download | Seal-D 681S | Free Hanging | Panel Mount, Through Hole | -55°C~155°C | Tray | 1 (Unlimited) | Solder | ROHS3 Compliant | 2012 | /files/norcompinc-780m44213r001-datasheets-2740.pdf | 5A | Black | 14 Weeks | Dust Tight, IP67, Waterproof | No SVHC | yes | Plug, Male Pins | 21 (17 + 4 Power) | Male | 21 | Copper Alloy | PBT | IP67 - Dust Tight, Waterproof | Polybutylene Terephthalate (PBT) | Grounding Indents | Steel | 2 | 5A 40A | Insulated | Nickel | Gold | 4 | Flash | UL94 V-0 | D-Sub, Combo | Signal and Power | Housing/Shell (Unthreaded) | 4 DC C - 21WA4 | Steel, Nickel Plated | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
172-050-142R031 | NorComp |
Min: 1 Mult: 1 |
download | 172, M Series | Through Hole | Panel Mount, Through Hole | -50°C~100°C | Tray | Not Applicable | Wire Wrap | ROHS3 Compliant | 2005 | /files/norcompinc-172015142r001-datasheets-6492.pdf | 5A | 67mm | 10.1mm | 15.4mm | Beige | Lead Free | 14 Weeks | Plug, Male Pins | 50 | Male | UL94 V-0 | EAR99 | Brass | PBT | Polybutylene Terephthalate (PBT), Polyester | Grounding Indents | Machined | 3 | Tin | Gold | Flash | UL94 V-0 | D-Sub | Signal | Mating Side (4-40) | 5 DD D | Steel, Tin Plated | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
174-009-112R141 | NorComp |
Min: 1 Mult: 1 |
download | 174, M Series | Through Hole | Panel Mount, Through Hole, Right Angle | -50°C~100°C | Tray | Not Applicable | Solder | 100°C | -50°C | RoHS Compliant | 2011 | /files/norcompinc-174037112r141-datasheets-9515.pdf | 5A | 30.8mm | 12.6mm | Beige | Lead Free | 14 Weeks | Plug, Male Pins | 9 | Male | Beige | UL94 V-0 | Brass | Gold | PBT | Polybutylene Terephthalate (PBT), Polyester | Grounding Indents, Mounting Brackets | Machined | 2 | 5A | Gold | Flash | UL94 V-0 | D-Sub | Signal | Mating Side, Female Screwlock (4-40) | 1 DE E | Steel, Tin Plated | 0.370 (9.40mm) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
184-025-193L001 | NorComp |
Min: 1 Mult: 1 |
download | 184 | Free Hanging | Panel Mount | -50°C~105°C | Tray | Not Applicable | IDC, Ribbon Cable | RoHS Compliant | 2005 | /files/norcompinc-184009193l031-datasheets-4844.pdf | 1A | 53mm | 18.5mm | Lead Free | yes | Plug, Male Pins | 25 | Male | UL94 V-0 | Brass | PBT | Polybutylene Terephthalate (PBT) | Feed Through, Grounding Indents | 2 | 26-28 AWG, Stranded | Insulated | Steel | Nickel | Gold | Flash | UL94 V-0 | D-Sub | Signal | Housing/Shell (Unthreaded) | 3 DB B | Steel, Nickel Plated | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
680-015-113R001 | NorComp |
Min: 1 Mult: 1 |
download | Seal-D 680 | Through Hole | Panel Mount, Through Hole | -50°C~100°C | Tray | 1 (Unlimited) | Solder | RoHS Compliant | 2012 | /files/norcompinc-780m44213r001-datasheets-2740.pdf | 5A | 500V | 12 Weeks | Dust Tight, IP66, Water Resistant | yes | Plug, Male Pins | 15 | Male | Brass | PBT | IP66 - Dust Tight, Water Resistant | Polybutylene Terephthalate (PBT) | Grounding Indents | Glass | Stamped | 3 | Insulated | Steel | Nickel | Gold | Flash | UL94 V-0 | D-Sub, High Density | Signal | Housing/Shell (Unthreaded) | 1 DE E High Density | Steel, Nickel Plated | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
681-026-113R171 | NorComp |
Min: 1 Mult: 1 |
download | Seal-D 681 | Through Hole | Panel Mount, Through Hole, Right Angle | -50°C~100°C | Tray | 1 (Unlimited) | Solder | RoHS Compliant | 2012 | /files/norcompinc-780m44213r001-datasheets-2740.pdf | 2A | Black | 12 Weeks | Dust Tight, IP66, Water Resistant | yes | Plug, Male Pins | 26 | Brass | Nylon | IP66 - Dust Tight, Water Resistant | Polyamide (PA9T), Nylon 9T | Ground Strap, Grounding Indents | 3 | Gold | Flash | UL94 V-0 | D-Sub, High Density | Signal | Housing/Shell (4-40) | 2 DA A High Density | Steel, Nickel Plated | 0.350 (8.89mm) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
671-015-103L011 | NorComp |
Min: 1 Mult: 1 |
download | Seal-D 671 | Free Hanging, Panel | Panel Mount | -50°C~100°C | Tray | 1 (Unlimited) | Solder Cup | RoHS Compliant | 2012 | /files/norcompinc-780m44213r001-datasheets-2740.pdf | 5A | Black | 12 Weeks | Dust Tight, IP66, Water Resistant | yes | Plug, Male Pins | 15 | Brass | PBT | IP66 - Dust Tight, Water Resistant | Polybutylene Terephthalate (PBT) | Grounding Indents | Stamped | 2 | 20-28 AWG | Gold | Flash | UL94 V-0 | D-Sub | Signal | Cable Side (4-40) | 2 DA A | Steel, Nickel Plated | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
680-026-103L001 | NorComp |
Min: 1 Mult: 1 |
download | Seal-D 680 | Free Hanging | Panel Mount | -50°C~100°C | Tray | 1 (Unlimited) | Solder Cup | RoHS Compliant | 2012 | /files/norcompinc-780m44213r001-datasheets-2740.pdf | 5A | 500V | 12 Weeks | Dust Tight, IP66, Water Resistant | yes | Plug, Male Pins | 26 | Male | Brass | PBT | IP66 - Dust Tight, Water Resistant | Polybutylene Terephthalate (PBT) | Grounding Indents | Glass | Stamped | 3 | Insulated | Steel | Nickel | Gold | Flash | UL94 V-0 | D-Sub, High Density | Signal | Housing/Shell (Unthreaded) | 2 DA A High Density | Steel, Nickel Plated | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
RJADK15S7080831 | NorComp |
Min: 1 Mult: 1 |
download | RJADK | Not Applicable | ROHS3 Compliant | 2007 | /files/norcompinc-rjadk15s7080831-datasheets-8053.pdf | Gray | 14 Weeks | No SVHC | 15 | D-Sub, Standard | RJ45 | Female | Female | D-Sub, 15 Pin Female | Modular, Female Jack, 8p8c (RJ45) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
110-050-103-001 | NorComp |
Min: 1 Mult: 1 |
download | SCSI | Centronics, 110- | Free Hanging | Free Hanging (In-Line) | Not Applicable | Solder Cup | Non-RoHS Compliant | 2002 | /files/norcompinc-110036103001-datasheets-9971.pdf | Contains Lead | Plug | 50 | Male | 50 | UL94 V-0 | Gold | Plastic | Backshell, Bail Lock, Strain Relief | 2 | Gold | Flash | Center Strip Contacts | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
111-050-113-001 | NorComp |
Min: 1 Mult: 1 |
download | SCSI | 111 | Through Hole | Through Hole | Not Applicable | Solder | Non-RoHS Compliant | 2002 | /files/norcompinc-111024113001-datasheets-0120.pdf | Contains Lead | Plug | 50 | Male | 50 | Blue | UL94 V-0 | Gold | Plastic | 2 | Gold | Flash | Center Strip Contacts | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
111-024-203L001 | NorComp |
Min: 1 Mult: 1 |
download | SCSI | 111 | Free Hanging | Free Hanging (In-Line) | Not Applicable | Solder Cup | ROHS3 Compliant | 2014 | /files/norcompinc-111024203l001-datasheets-2857.pdf | 5A | Lead Free | 14 Weeks | No SVHC | yes | Receptacle | 24 | Blue | UL94 V-0 | Bronze | Plastic | Bail Lock | 2 | Gold | Flash | Outer Shroud Contacts | Housing/Shell (Unthreaded) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
111-050-203L001 | NorComp |
Min: 1 Mult: 1 |
download | SCSI | 111 | Free Hanging | Free Hanging (In-Line) | Not Applicable | Solder Cup | ROHS3 Compliant | 2014 | /files/norcompinc-111024203l001-datasheets-2857.pdf | 5A | Lead Free | 14 Weeks | No SVHC | yes | Receptacle | 50 | Blue | UL94 V-0 | Bronze | Plastic | Bail Lock | 2 | Gold | Flash | Outer Shroud Contacts | Housing/Shell (Unthreaded) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
110-014-203L001 | NorComp |
Min: 1 Mult: 1 |
download | SCSI | Centronics, 110- | Free Hanging | Free Hanging (In-Line) | Not Applicable | Solder Cup | RoHS Compliant | 2008 | /files/norcompinc-110014203l001-datasheets-2071.pdf | 5A | Lead Free | No SVHC | yes | Receptacle | 14 | NO | NO | NO | NO | NO | GENERAL PURPOSE | MULTIPLE MATING PARTS AVAILABLE | FEMALE | NO | UL94 V-0 | EAR99 | Copper | Plastic | 14 | unknown | 8536.69.40.30 | Assembly Hardware, Backshell, Bail Lock, Strain Relief | 2 | STEEL | Gold | NICKEL | 94V-0 | Flash | Outer Shroud Contacts | Housing/Shell (Unthreaded) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
854103M-DC | NorComp |
Min: 1 Mult: 1 |
download | VULCON™. | 1 (Unlimited) | ROHS3 Compliant | 2015 | /files/norcompinc-854103mdc-datasheets-0463.pdf | Metal | Silver | Brass | 14 Weeks | No SVHC | Cap (Cover), Dust | no | Metal Chain with Ring | M8 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
GCLP15F15F | NorComp |
Min: 1 Mult: 1 |
download | GCLP | Free Hanging | Panel Mount | -55°C~105°C | Not Applicable | ROHS3 Compliant | 2011 | /files/norcompinc-gclp15f15f-datasheets-5250.pdf | 14 Weeks | No SVHC | 15 | Yellow | D-Sub, Standard | D-Sub, Standard | Female | 2 | 5A | 5 pcs - 1 Connector, 2 Jack Screws, 2 Nuts | Gold | Flash | UL94 V-0 | D-Sub, 15 Pin Female | D-Sub, 15 Pin Female | Gender Changer | Steel, Tin Plated | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
GCLP25M25M | NorComp |
Min: 1 Mult: 1 |
download | GCLP | Free Hanging | Panel Mount | -55°C~105°C | Not Applicable | ROHS3 Compliant | 2011 | /files/norcompinc-gclp25m25m-datasheets-5559.pdf | 14 Weeks | No SVHC | 25 | Yellow | D-Sub, Standard | D-Sub, Standard | Male | Male | 2 | 5A | 3 pcs - 1 Connector, 2 Jack Screws | Gold | Flash | UL94 V-0 | D-Sub, 25 Pin Male | D-Sub, 25 Pin Male | Gender Changer | Steel, Tin Plated | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
180-002-170-001 | NorComp |
Min: 1 Mult: 1 |
download | Signal | 180 | Tape & Reel (TR) | Not Applicable | Crimp | Non-RoHS Compliant | 2002 | /files/norcompinc-180002170001-datasheets-7081.pdf | Contains Lead | Socket | Phosphor Bronze | Gold | High Density (HD), Insulation Support | Stamped | 22-26 AWG | 26 AWG | 22 AWG | Gold | 10.0μin 0.25μm | Female Socket | Crimp | Nickel | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
180-102-170L001 | NorComp |
Min: 1 Mult: 1 |
download | Signal | 180 | Tray | 1 (Unlimited) | ROHS3 Compliant | 2008 | /files/norcompinc-180102170l001-datasheets-0387.pdf | 5A | 15 Weeks | No SVHC | Socket | NO | NO | NO | Female | UNDER PLATING THICKNES: 50 | Phosphor Bronze | 24 AWG | High Density (HD), Insulation Support | CONTACT | Stamped | 0.24 inch | 24-26 AWG | 26 AWG | 24 AWG | Gold | 10.0μin 0.25μm | Female Socket | Crimp | Nickel | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
180-078-172L020 | NorComp |
Min: 1 Mult: 1 |
download | 180 | Free Hanging | Free Hanging (In-Line) | -50°C~100°C | Tray | 1 (Unlimited) | ROHS3 Compliant | 2008 | /files/norcompinc-180078172l000-datasheets-1445.pdf | 14 Weeks | Plug for Male Contacts | 78 | Male | Shielded | 4 | D-Sub, High Density | Signal | Cable Side (4-40) | 5 DD D High Density | Steel, Tin Plated | Contacts Not Included | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
180-015-272L000 | NorComp |
Min: 1 Mult: 1 |
download | 180 | Free Hanging | Free Hanging (In-Line) | -50°C~100°C | Tray | 1 (Unlimited) | Crimp | 500V | ROHS3 Compliant | 2008 | /files/norcompinc-180078273l020-datasheets-1428.pdf | 5A | 14 Weeks | yes | Receptacle for Female Contacts | 15 | Receptacle | NO | NO | NO | NO | NO | GENERAL PURPOSE | YES | EAR99 | BRASS | Gold | 15 | e4 | Shielded | Glass | 3 | Insulated | Steel | Tin | TIN | 94V-0 | D-Sub, High Density | Signal | Housing/Shell (Unthreaded) | 1 DE E High Density | Steel, Tin Plated | Contacts Not Included | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||
170-015-172L030 | NorComp |
Min: 1 Mult: 1 |
download | 170 | Free Hanging | Free Hanging (In-Line) | -50°C~125°C | Tray | Not Applicable | Crimp | ROHS3 Compliant | 2008 | /files/norcompinc-170025173l000-datasheets-3229.pdf | Black | 14 Weeks | Plug for Male Contacts | 15 | Male | Polybutylene Terephthalate (PBT), Glass Filled | 2 | D-Sub | Signal | Mating Side (4-40) | 2 DA A | Steel, Tin Plated | Contacts Not Included |
Please send RFQ , we will respond immediately.