NorComp(4494)

Compare Image Name Manufacturer Pricing(USD) Quantity Weight(Kg) Size(LxWxH) Part Status Type Series Mount Mounting Type Operating Temperature Packaging Moisture Sensitivity Level (MSL) Termination RoHS Status Published Datasheet Current Rating Package / Case Length Height Width Voltage - Rated AC Color Lead Free Material Factory Lead Time Ratings REACH SVHC Number of Pins Pbfree Code Connector Type Number of Positions Gender MIL Conformance DIN Conformance IEC Conformance Filter Feature Mixed Contacts Option Number of Contacts Contact Gender Empty Shell Housing Color Contact Finish - Mating Number of Ports Flammability Rating ECCN Code Contact Material Contact Plating Housing Material Total Number of Contacts Reach Compliance Code Ingress Protection HTS Code Dielectric Material JESD-609 Code Feature Pitch Body Material Connector Type A Connector Type B Insulation Material Connector Support Type Contact Form Termination Type Gender Type A Number of Rows Wire Gauge Wire Gauge (Max) Wire Gauge (Min) Current Rating (Amps) Includes Insulation Shell Material Contact Finish Termination Plating Contact Finish Shell Finish UL Flammability Code Fastening Type Number of Power Positions Contact Finish Thickness Material Flammability Rating Convert From (Adapter End) Convert To (Adapter End) Connector Style Contact Type Flange Feature Shell Size, Connector Layout Shell Material, Finish Backset Spacing Contact Termination Note
172-015-283L001 172-015-283L001 NorComp
RFQ

Min: 1

Mult: 1

download 172, M Series Through Hole Panel Mount, Through Hole -50°C~125°C Tray Not Applicable Solder ROHS3 Compliant 2005 /files/norcompinc-172009283l021-datasheets-8069.pdf 5A 39.2mm 12.6mm Black Lead Free 14 Weeks yes Receptacle, Female Sockets 15 Female UL94 V-0 Brass PBT Polybutylene Terephthalate (PBT) Machined 2 Gold Flash UL94 V-0 D-Sub Signal Housing/Shell (Unthreaded) 2 DA A Steel, Nickel Plated
180-044-213R911 180-044-213R911 NorComp
RFQ

Min: 1

Mult: 1

download 180 Through Hole Panel Mount, Through Hole -50°C~100°C Tray 1 (Unlimited) Solder ROHS3 Compliant 2007 /files/norcompinc-180026213r911-datasheets-4777.pdf 5A 500V Lead Free Metal 14 Weeks No SVHC Receptacle, Female Sockets 44 Receptacle NO NO NO NO NO GENERAL PURPOSE NO EAR99 Brass PBT 44 Polybutylene Terephthalate (PBT) Board Lock, Shielded Steel 3 3A Nickel Gold 94V-0 Flash UL94 V-0 D-Sub, High Density Signal Board Side (4-40); Mating Side, Female Screwlock (4-40) 3 DB B High Density Steel, Nickel Plated
680S21W1103L201 680S21W1103L201 NorComp
RFQ

Min: 1

Mult: 1

download Seal-D 680S Panel Mount -55°C~155°C Tray 1 (Unlimited) Solder Cup ROHS3 Compliant 2012 /files/norcompinc-780m44213r001-datasheets-2740.pdf 5A Black 14 Weeks Dust Tight, IP67, Waterproof No SVHC yes Plug, Male Pins 21 (20 + 1 Power) Male 21 Copper Alloy IP67 - Dust Tight, Waterproof Polybutylene Terephthalate (PBT), Glass Filled Grounding Indents Steel PBT 2 5A 20A Insulated Nickel Gold 1 Flash UL94 V-0 D-Sub, Combo Signal and Power Housing/Shell (Unthreaded) 3 DB B - 21W1 Steel, Nickel Plated
172-E50-203R011 172-E50-203R011 NorComp
RFQ

Min: 1

Mult: 1

download 172-E, M Series Free Hanging, Panel Panel Mount -50°C~100°C Tray Not Applicable Solder Cup ROHS3 Compliant 2005 /files/norcompinc-172e37202r021-datasheets-3413.pdf 5A 67mm 10.2mm 15.3mm White Lead Free 14 Weeks yes Receptacle, Female Sockets 50 Female NO NO NO NO NO GENERAL PURPOSE NO UL94 V-0 Brass PBT 50 Polybutylene Terephthalate (PBT) Machined 3 20-26 AWG Nickel Gold 94V-0 Flash UL94 V-0 D-Sub Signal Cable Side (4-40) 5 DD D Steel, Nickel Plated
772-E25-103R011 772-E25-103R011 NorComp
RFQ

Min: 1

Mult: 1

download Seal-D 772-E Free Hanging, Panel Panel Mount -50°C~100°C Tray 1 (Unlimited) Solder Cup ROHS3 Compliant 2012 /files/norcompinc-772e09103r001-datasheets-6815.pdf 5A White 14 Weeks Dust Tight, IP67, Waterproof yes Plug, Male Pins 25 Male Brass PBT unknown IP67 - Dust Tight, Waterproof Polybutylene Terephthalate (PBT) Grounding Indents Machined 2 20-26 AWG Gold Flash UL94 V-0 D-Sub Signal Cable Side (4-40) 3 DB B Steel, Nickel Plated
684S13W6103L461 684S13W6103L461 NorComp
RFQ

Min: 1

Mult: 1

download Seal-D 684S Free Hanging Board Edge, Through Hole, Right Angle -55°C~125°C Tray 1 (Unlimited) Solder ROHS3 Compliant 2012 /files/norcompinc-780m44213r001-datasheets-2740.pdf 5A Black 14 Weeks Dust Tight, IP67, Waterproof No SVHC yes Plug, Male Pins 13 (7 + 6 Power) Male 13 Copper Alloy PBT IP67 - Dust Tight, Waterproof Polybutylene Terephthalate (PBT), Glass Filled Board Lock, Grounding Indents, Mounting Brackets Steel Machined 2 5A 40A Insulated Nickel Gold 6 Flash UL94 V-0 D-Sub, Combo Signal and Power Housing/Shell (4-40) 4 DC C - 13W6 Steel, Nickel Plated 0.370 (9.40mm)
681S13W6103L001 681S13W6103L001 NorComp
RFQ

Min: 1

Mult: 1

download Seal-D 681S Free Hanging Panel Mount, Through Hole -55°C~155°C Tray 1 (Unlimited) Solder ROHS3 Compliant 2012 /files/norcompinc-780m44213r001-datasheets-2740.pdf 5A Black 14 Weeks Dust Tight, IP67, Waterproof No SVHC yes Plug, Male Pins 13 (7 + 6 Power) Male 13 Copper Alloy PBT IP67 - Dust Tight, Waterproof Polybutylene Terephthalate (PBT) Grounding Indents Steel 2 5A 40A Insulated Nickel Gold 6 Flash UL94 V-0 D-Sub, Combo Signal and Power Housing/Shell (Unthreaded) 4 DC C - 13W6 Steel, Nickel Plated
182-025-113R481 182-025-113R481 NorComp
RFQ

Min: 1

Mult: 1

download 182 Through Hole Panel Mount, Through Hole, Right Angle -55°C~105°C Tray Solder ROHS3 Compliant 2009 /files/norcompinc-182037113r161-datasheets-3788.pdf 5A 53mm 12.5mm 24.9mm Black Lead Free 12 Weeks yes Plug, Male Pins 25 Male NO NO NO NO NO GENERAL PURPOSE NO UL94 V-0 Brass Nylon 25 Polyamide (PA9T), Nylon 9T Grounding Indents 2 Gold 94V-0 Flash UL94 V-0 D-Sub Signal Mating Side, Female Screwlock (4-40) 3 DB B Steel, Nickel Plated 0.318 (8.08mm)
382-015-112L565 382-015-112L565 NorComp
RFQ

Min: 1

Mult: 1

download Micro-D 382 Panel, Through Hole Board Edge, Through Hole, Right Angle -55°C~85°C Tube 1 (Unlimited) Solder RoHS Compliant 2011 /files/norcompinc-382015112l565-datasheets-3899.pdf 1A 12 Weeks No SVHC yes Plug, Male Pins 15, 15 Male to Male 30 2 EAR99 Copper Alloy Board Lock, Shielded 1.27mm Steel Thermoplastic 2, 2 Insulated Copper, Tin Gold 15.0μin 0.38μm UL94 V-0 D-Type, Micro-D - Stacked Signal Mating Side, Female Screwlock (2-56) 0.050 Pitch x 0.043 Row to Row Steel, Tin Plated
680-015-103L011 680-015-103L011 NorComp
RFQ

Min: 1

Mult: 1

download Seal-D 680 Free Hanging, Panel Panel Mount -50°C~100°C Tray 1 (Unlimited) Solder Cup RoHS Compliant 2012 /files/norcompinc-780m44213r001-datasheets-2740.pdf 5A 12 Weeks Dust Tight, IP66, Water Resistant yes Plug, Male Pins 15 Brass PBT IP66 - Dust Tight, Water Resistant Polybutylene Terephthalate (PBT) Grounding Indents Stamped 3 Gold Flash UL94 V-0 D-Sub, High Density Signal Cable Side (4-40) 1 DE E High Density Steel, Nickel Plated
671-025-103L031 671-025-103L031 NorComp
RFQ

Min: 1

Mult: 1

download Seal-D 671 Free Hanging, Panel Panel Mount -50°C~100°C Tray 1 (Unlimited) Solder Cup RoHS Compliant 2012 /files/norcompinc-780m44213r001-datasheets-2740.pdf 5A Black 12 Weeks Dust Tight, IP66, Water Resistant yes Plug, Male Pins 25 Brass PBT IP66 - Dust Tight, Water Resistant Polybutylene Terephthalate (PBT) Grounding Indents Stamped 2 20-28 AWG Gold Flash UL94 V-0 D-Sub Signal Mating Side (4-40) 3 DB B Steel, Nickel Plated
680-026-113R051 680-026-113R051 NorComp
RFQ

Min: 1

Mult: 1

download Seal-D 680 Through Hole Panel Mount, Through Hole -50°C~100°C Tray 1 (Unlimited) Solder RoHS Compliant 2012 /files/norcompinc-780m44213r001-datasheets-2740.pdf 5A 12 Weeks Dust Tight, IP66, Water Resistant yes Plug, Male Pins 26 Brass PBT IP66 - Dust Tight, Water Resistant Polybutylene Terephthalate (PBT) Board Lock, Grounding Indents Stamped 3 Gold Flash UL94 V-0 D-Sub, High Density Signal Board Side (4-40) 2 DA A High Density Steel, Nickel Plated
680-044-113R011 680-044-113R011 NorComp
RFQ

Min: 1

Mult: 1

download Seal-D 680 Through Hole Panel Mount, Through Hole -50°C~100°C Tray 1 (Unlimited) Solder RoHS Compliant 2012 /files/norcompinc-780m44213r001-datasheets-2740.pdf 5A 12 Weeks Dust Tight, IP66, Water Resistant yes Plug, Male Pins 44 Brass PBT IP66 - Dust Tight, Water Resistant Polybutylene Terephthalate (PBT) Grounding Indents Stamped 3 Gold Flash UL94 V-0 D-Sub, High Density Signal Board Side (4-40) 3 DB B High Density Steel, Nickel Plated
RJADK15S7080821 RJADK15S7080821 NorComp
RFQ

Min: 1

Mult: 1

download RJADK ROHS3 Compliant 2007 /files/norcompinc-rjadk15s7080831-datasheets-8053.pdf 14 Weeks No SVHC 15 NOT SPECIFIED NOT SPECIFIED D-Sub, Standard RJ45 Female D-Sub, 15 Pin Female Modular, Female Jack, 8p8c (RJ45)
111-036-203-001 111-036-203-001 NorComp
RFQ

Min: 1

Mult: 1

download SCSI 111 Free Hanging Free Hanging (In-Line) Not Applicable Solder Cup Non-RoHS Compliant 2002 /files/norcompinc-111036203001-datasheets-0094.pdf Contains Lead Receptacle 36 Female 36 Blue UL94 V-0 Gold Plastic Bail Lock 2 Gold Flash Outer Shroud Contacts Housing/Shell (Unthreaded)
112-024-113-001 112-024-113-001 NorComp
RFQ

Min: 1

Mult: 1

download SCSI 112 Through Hole Through Hole, Right Angle Not Applicable Solder Non-RoHS Compliant 2002 /files/norcompinc-112050113001-datasheets-0081.pdf Contains Lead Plug 24 Male 24 Blue UL94 V-0 Gold Plastic 2 Gold Flash Center Strip Contacts Housing/Shell (4-40)
111-014-213L001 111-014-213L001 NorComp
RFQ

Min: 1

Mult: 1

download SCSI 111 Through Hole Through Hole Not Applicable Solder ROHS3 Compliant 2012 /files/norcompinc-111036213l001-datasheets-3262.pdf 5A Lead Free 14 Weeks No SVHC yes Receptacle 14 NO NO NO NO NO GENERAL PURPOSE FEMALE NO Blue UL94 V-0 EAR99 Bronze Plastic 14 8536.69.40.30 e3 Bail Lock 2 STEEL Gold NICKEL 94V-0 Flash Outer Shroud Contacts Housing/Shell (Unthreaded)
112-024-113R491 112-024-113R491 NorComp
RFQ

Min: 1

Mult: 1

download SCSI 112 Through Hole Through Hole, Right Angle Solder ROHS3 Compliant 2014 /files/norcompinc-112024113r491-datasheets-9489.pdf 14 Weeks yes Plug 24 Board Lock 2 Gold Flash Center Strip Contacts Housing/Shell (4-40)
988-050-030L121 988-050-030L121 NorComp
RFQ

Min: 1

Mult: 1

download HD50 (SCSI) 988 Free Hanging Free Hanging (In-Line) 1 (Unlimited) Solder Cup ROHS3 Compliant 2009 /files/norcompinc-179037413r571-datasheets-2679.pdf 12 Weeks Plug 50 Assembly Hardware, Backshell, Strain Relief 2 Center Strip Contacts
IPRJPLUGCOVER-M IPRJPLUGCOVER-M NorComp
RFQ

Min: 1

Mult: 1

download Free Hanging Free Hanging (In-Line) Bulk 1 (Unlimited) ROHS3 Compliant 2014 /files/norcompinc-iprjplugcoverm-datasheets-7605.pdf Metal Silver 14 Weeks Dust Tight, IP67, Waterproof no Housing for Prewired RJ45 Cordset Male Zinc Alloy IP67 - Dust Tight, Waterproof CONNECTOR ACCESSORY Bayonet Lock Plug Not Provided
GCLP15M15M GCLP15M15M NorComp
RFQ

Min: 1

Mult: 1

download GCLP Free Hanging Panel Mount -55°C~105°C Not Applicable ROHS3 Compliant 2011 /files/norcompinc-gclp15m15m-datasheets-5371.pdf 14 Weeks No SVHC 15 Yellow D-Sub, Standard D-Sub, Standard Male 2 5A 3 pcs - 1 Connector, 2 Jack Screws Gold Flash UL94 V-0 D-Sub, 15 Pin Male D-Sub, 15 Pin Male Gender Changer Steel, Tin Plated
682002170001 682002170001 NorComp
RFQ

Min: 1

Mult: 1

download Coaxial 682 Bulk Not Applicable Non-RoHS Compliant 2005 /files/norcompinc-6825w1102001-datasheets-1657.pdf Stamped RG-179 Female Socket Solder
170-001-170L001 170-001-170L001 NorComp
RFQ

Min: 1

Mult: 1

download Signal 170 Tape & Reel (TR) Not Applicable ROHS3 Compliant 2011 /files/norcompinc-170001170l002-datasheets-8728.pdf Lead Free 14 Weeks yes Male Pin Male Brass Insulation Support Stamped 24-28 AWG 28 AWG 24 AWG Gold Flash Male Pin Crimp
180-078-172L000 180-078-172L000 NorComp
RFQ

Min: 1

Mult: 1

download 180 Free Hanging Free Hanging (In-Line) -50°C~100°C Tray 1 (Unlimited) ROHS3 Compliant 2008 /files/norcompinc-180078172l000-datasheets-1445.pdf Lead Free 14 Weeks Plug for Male Contacts 78 Male Shielded 4 D-Sub, High Density Signal Housing/Shell (Unthreaded) 5 DD D High Density Steel, Tin Plated Contacts Not Included
170-037-272L000 170-037-272L000 NorComp
RFQ

Min: 1

Mult: 1

download 170 Free Hanging Free Hanging (In-Line) -50°C~125°C Tray Not Applicable ROHS3 Compliant 2008 /files/norcompinc-170015273l000-datasheets-3303.pdf Black 14 Weeks Receptacle for Female Contacts 37 Receptacle NO NO NO NO NO GENERAL PURPOSE YES NOT SPECIFIED EAR99 NOT SPECIFIED 37 8536.69.40.30 Polybutylene Terephthalate (PBT) CRIMP 2 TIN 94V-0 D-Sub Signal Housing/Shell (Unthreaded) 4 DC C Steel, Tin Plated Contacts Not Included
180-062-173L000 180-062-173L000 NorComp
RFQ

Min: 1

Mult: 1

download 180 Free Hanging Free Hanging (In-Line) -50°C~100°C Tray Not Applicable Crimp ROHS3 Compliant 2005 /files/norcompinc-180078172l000-datasheets-1445.pdf 2A 69.4mm 15.4mm Lead Free 14 Weeks yes Plug for Male Contacts 62 Male Grounding Indents 3 Steel Nickel D-Sub, High Density Signal Housing/Shell (Unthreaded) 4 DC C High Density Steel, Nickel Plated Contacts Not Included
170-015-273L010 170-015-273L010 NorComp
RFQ

Min: 1

Mult: 1

download 170 Free Hanging Free Hanging (In-Line) -50°C~125°C Tray Not Applicable Crimp ROHS3 Compliant 2008 /files/norcompinc-170015273l000-datasheets-3303.pdf 39.1mm 12.6mm Black Lead Free 14 Weeks Receptacle for Female Contacts 15 Female NO NO NO NO NO GENERAL PURPOSE YES NOT SPECIFIED EAR99 NOT SPECIFIED 15 8536.69.40.30 Polybutylene Terephthalate (PBT) 2 94V-0 D-Sub Signal Cable Side (4-40) 2 DA A Steel, Nickel Plated Contacts Not Included
170-037-173L000 170-037-173L000 NorComp
RFQ

Min: 1

Mult: 1

download 170 Free Hanging Free Hanging (In-Line) -50°C~125°C Tray Not Applicable Through Hole ROHS3 Compliant 2008 /files/norcompinc-170025173l000-datasheets-3229.pdf 5A 69.4mm 12.6mm Black Lead Free 14 Weeks No SVHC yes Plug for Male Contacts 37 Male Gold Polybutylene Terephthalate (PBT), Glass Filled Grounding Indents Steel 2 Chromate Tin D-Sub Signal Housing/Shell (Unthreaded) 4 DC C Steel, Nickel Plated Contacts Not Included
180-015-272L030 180-015-272L030 NorComp
RFQ

Min: 1

Mult: 1

download 180 Free Hanging Free Hanging (In-Line) -50°C~100°C Tray 1 (Unlimited) ROHS3 Compliant 2008 /files/norcompinc-180078273l020-datasheets-1428.pdf 14 Weeks yes Receptacle for Female Contacts 15 Female NO NO NO NO NO GENERAL PURPOSE YES GOLD OVER NICKEL BRASS 15 e4 Shielded GLASS FILLED POLYBUTYLENE TEREPHTHALATE/NYLON66 CRIMP 3 Gold (Au) - with Nickel (Ni) barrier TIN 94V-0 D-Sub, High Density Signal Mating Side (4-40) 1 DE E High Density Steel, Tin Plated Contacts Not Included
170-015-272L030 170-015-272L030 NorComp
RFQ

Min: 1

Mult: 1

download 170 Free Hanging Free Hanging (In-Line) -50°C~125°C Tray 1 (Unlimited) ROHS3 Compliant 2013 /files/norcompinc-170015273l000-datasheets-3303.pdf Black 14 Weeks Receptacle for Female Contacts 15 Female NO NO NO NO NO GENERAL PURPOSE YES NOT SPECIFIED EAR99 NOT SPECIFIED 15 8536.69.40.30 Polybutylene Terephthalate (PBT) CRIMP 2 TIN 94V-0 D-Sub Signal Mating Side (4-40) 2 DA A Steel, Tin Plated Contacts Not Included

In Stock

Please send RFQ , we will respond immediately.