Honeywell Aerospace(8920)

Compare Image Name Manufacturer Pricing(USD) Quantity Weight(Kg) Size(LxWxH) Part Status Series Operating Temperature Moisture Sensitivity Level (MSL) Termination Max Operating Temperature Min Operating Temperature RoHS Status Published Datasheet Package / Case Factory Lead Time Accessory Type Feature Applications Voltage - Supply Accuracy Termination Style Output Type Output Port Size Port Style Max Pressure Pressure Type Operating Pressure Maximum Pressure
PPTE1500AP5VDF-E024 PPTE1500AP5VDF-E024 Honeywell Aerospace
RFQ

Min: 1

Mult: 1

download PPTE -40°C~85°C Not Applicable Non-RoHS Compliant https://pdf.utmel.com/r/datasheets/honeywellaerospace-ppte0100ap2vdc-datasheets-1646.pdf Cylinder Industrial Automation 6V~30V ±0.24% Cable Analog, RS-485 0 V ~ 5 V Female - 1/4 6.35mm NPT Threaded Absolute 1500PSI (10342.14kPa) 4500PSI (31026.41kPa)
PPTE0050AP5VDF-E017 PPTE0050AP5VDF-E017 Honeywell Aerospace
RFQ

Min: 1

Mult: 1

download PPTE -40°C~85°C Not Applicable Non-RoHS Compliant https://pdf.utmel.com/r/datasheets/honeywellaerospace-ppte0100ap2vdc-datasheets-1646.pdf Cylinder Industrial Automation 6V~30V ±0.24% Cable Analog, RS-485 0 V ~ 5 V Female - 1/4 6.35mm NPT Threaded Absolute 50PSI (344.74kPa) 150PSI (1034.21kPa)
PPTE0500GP5VDF-E024 PPTE0500GP5VDF-E024 Honeywell Aerospace
RFQ

Min: 1

Mult: 1

download PPTE -40°C~85°C Not Applicable Non-RoHS Compliant https://pdf.utmel.com/r/datasheets/honeywellaerospace-ppte0100ap2vdc-datasheets-1646.pdf Cylinder Industrial Automation 6V~30V ±0.24% Cable Analog, RS-485 0 V ~ 5 V Female - 1/4 6.35mm NPT Threaded Vented Gauge 500PSI (3447.38kPa) 1500PSI (10342.14kPa)
PPTR0020AP5VB-R018 PPTR0020AP5VB-R018 Honeywell Aerospace
RFQ

Min: 1

Mult: 1

download PPTR -40°C~85°C Not Applicable Non-RoHS Compliant https://pdf.utmel.com/r/datasheets/honeywellaerospace-pptr0020ap2vb-datasheets-1402.pdf Cylinder Industrial Automation 6V~30V ±0.24% Connector Analog, RS-485 0 V ~ 5 V Female - 1/4 6.35mm NPT Threaded Absolute 20PSI (137.9kPa) 60PSI (413.69kPa)
PPTR0028GP2VB-R033 PPTR0028GP2VB-R033 Honeywell Aerospace
RFQ

Min: 1

Mult: 1

download PPTR -40°C~85°C Not Applicable Non-RoHS Compliant https://pdf.utmel.com/r/datasheets/honeywellaerospace-pptr0020ap2vb-datasheets-1402.pdf Cylinder Industrial Automation 6V~30V ±0.24% Connector Analog, RS-232 0 V ~ 5 V Female - 1/4 6.35mm NPT Threaded Vented Gauge 28PSI (193.05kPa) 84PSI (579.16kPa)
PPTR0028GP5VD-R033 PPTR0028GP5VD-R033 Honeywell Aerospace
RFQ

Min: 1

Mult: 1

download PPTR -40°C~85°C Not Applicable Non-RoHS Compliant https://pdf.utmel.com/r/datasheets/honeywellaerospace-pptr0020ap2vb-datasheets-1402.pdf Cylinder Industrial Automation 6V~30V ±0.24% Cable Analog, RS-485 0 V ~ 5 V Female - 1/4 6.35mm NPT Threaded Vented Gauge 28PSI (193.05kPa) 84PSI (579.16kPa)
PPTR0020GP2VD PPTR0020GP2VD Honeywell Aerospace
RFQ

Min: 1

Mult: 1

download PPTR -40°C~85°C Not Applicable Non-RoHS Compliant https://pdf.utmel.com/r/datasheets/honeywellaerospace-pptr0020ap2vb-datasheets-1402.pdf Cylinder Industrial Automation 6V~30V ±0.24% Cable Analog, RS-232 0 V ~ 5 V Female - 1/4 6.35mm NPT Threaded Vented Gauge 20PSI (137.9kPa) 60PSI (413.69kPa)
PPTR0032GP2VD-R072 PPTR0032GP2VD-R072 Honeywell Aerospace
RFQ

Min: 1

Mult: 1

download PPTR -40°C~85°C Not Applicable Non-RoHS Compliant https://pdf.utmel.com/r/datasheets/honeywellaerospace-pptr0020ap2vb-datasheets-1402.pdf Cylinder Industrial Automation 6V~30V ±0.24% Cable Analog, RS-232 0 V ~ 5 V Female - 1/4 6.35mm NPT Threaded Vented Gauge 32PSI (220.63kPa) 96PSI (661.9kPa)
PPTR0040GP2VD-R092 PPTR0040GP2VD-R092 Honeywell Aerospace
RFQ

Min: 1

Mult: 1

download PPTR -40°C~85°C Not Applicable Non-RoHS Compliant https://pdf.utmel.com/r/datasheets/honeywellaerospace-pptr0020ap2vb-datasheets-1402.pdf Cylinder Industrial Automation 6V~30V ±0.24% Cable Analog, RS-232 0 V ~ 5 V Female - 1/4 6.35mm NPT Threaded Vented Gauge 40PSI (275.79kPa) 120PSI (827.37kPa)
PPTR0020AP5VD PPTR0020AP5VD Honeywell Aerospace
RFQ

Min: 1

Mult: 1

download PPTR -40°C~85°C Not Applicable Non-RoHS Compliant https://pdf.utmel.com/r/datasheets/honeywellaerospace-pptr0020ap2vb-datasheets-1402.pdf Cylinder Industrial Automation 6V~30V ±0.24% Cable Analog, RS-485 0 V ~ 5 V Female - 1/4 6.35mm NPT Threaded Absolute 20PSI (137.9kPa) 60PSI (413.69kPa)
PPTR0100AP2VB-R099 PPTR0100AP2VB-R099 Honeywell Aerospace
RFQ

Min: 1

Mult: 1

download PPTR -40°C~85°C Not Applicable Non-RoHS Compliant https://pdf.utmel.com/r/datasheets/honeywellaerospace-pptr0020ap2vb-datasheets-1402.pdf Cylinder Industrial Automation 6V~30V ±0.24% Connector Analog, RS-232 0 V ~ 5 V Female - 1/4 6.35mm NPT Threaded Absolute 100PSI (689.48kPa) 300PSI (2068.43kPa)
58037093-001 58037093-001 Honeywell Aerospace
RFQ

Min: 1

Mult: 1

download Not Applicable RoHS Compliant 2014 /files/honeywellaerospace-58037093003-datasheets-6191.pdf 13 Weeks Power Supply Cable
PPTR0100AP5VD PPTR0100AP5VD Honeywell Aerospace
RFQ

Min: 1

Mult: 1

download PPTR -40°C~85°C Not Applicable Non-RoHS Compliant https://pdf.utmel.com/r/datasheets/honeywellaerospace-pptr0020ap2vb-datasheets-1402.pdf Cylinder Industrial Automation 6V~30V ±0.24% Cable Analog, RS-485 0 V ~ 5 V Female - 1/4 6.35mm NPT Threaded Absolute 100PSI (689.48kPa) 300PSI (2068.43kPa)
IPT0020A33R IPT0020A33R Honeywell Aerospace
RFQ

Min: 1

Mult: 1

download -40°C~85°C 1 (Unlimited) SMD/SMT 85°C -40°C RoHS Compliant 2011 /files/honeywellaerospace-ipt0050a33r-datasheets-2021.pdf Module 16 Weeks Temperature Compensated Board Mount 4V~12V ±0.04% Connector SPI 24 b Male - 0.26 6.71mm Tube Barbless 60 PSI Absolute 20PSI (137.9kPa) 60PSI (413.69kPa)
PPTR0150AN5VB-R064 PPTR0150AN5VB-R064 Honeywell Aerospace
RFQ

Min: 1

Mult: 1

download PPTR -40°C~85°C Not Applicable Non-RoHS Compliant https://pdf.utmel.com/r/datasheets/honeywellaerospace-ppt0002grr5vb-datasheets-5877.pdf Cylinder Industrial Automation 6V~30V ±0.24% Connector Analog, RS-485 0 V ~ 5 V Female - 1/4 6.35mm NPT Threaded Absolute 150PSI (1034.21kPa) 450PSI (3102.64kPa)
PPT0005DRR5VB PPT0005DRR5VB Honeywell Aerospace
RFQ

Min: 1

Mult: 1

download -40°C~85°C 1 (Unlimited) Non-RoHS Compliant 2012 https://pdf.utmel.com/r/datasheets/honeywellaerospace-ppt0002grr5vb-datasheets-5875.pdf Module Cube 11 Weeks Industrial Automation 5.5V~30V ±0.05% Connector Analog, RS-485 0 V ~ 5 V Male - 0.13 3.18mm Tube Dual Barbed 15 PSI Differential ±5PSI (±34.47kPa) ±15PSI (±103.42kPa)
PPTR0250AP5VD-R016 PPTR0250AP5VD-R016 Honeywell Aerospace
RFQ

Min: 1

Mult: 1

download PPTR -40°C~85°C Not Applicable Non-RoHS Compliant https://pdf.utmel.com/r/datasheets/honeywellaerospace-pptr0020ap2vb-datasheets-1402.pdf Cylinder Industrial Automation 6V~30V ±0.24% Cable Analog, RS-485 0 V ~ 5 V Female - 1/4 6.35mm NPT Threaded Absolute 250PSI (1723.69kPa) 750PSI (5171.07kPa)
PPT0005GXW5VB PPT0005GXW5VB Honeywell Aerospace
RFQ

Min: 1

Mult: 1

download -40°C~85°C 1 (Unlimited) Non-RoHS Compliant 2012 https://pdf.utmel.com/r/datasheets/honeywellaerospace-ppt0002grr5vb-datasheets-5875.pdf Module Cube 11 Weeks Industrial Automation 5.5V~30V ±0.05% Connector Analog, RS-485 0 V ~ 5 V Female - 1/8" 3.18mm Swagelok? Male - 0.13" 3.18mm Tube Barbed, Threaded 15 PSI Vented Gauge 5PSI (34.47kPa) 15PSI (103.42kPa)
PPTR0100GP5VD-R018 PPTR0100GP5VD-R018 Honeywell Aerospace
RFQ

Min: 1

Mult: 1

download PPTR -40°C~85°C Not Applicable Non-RoHS Compliant /files/honeywellaerospace-pptr0020ap2vb-datasheets-1402.pdf Cylinder Industrial Automation 6V~30V ±0.24% Cable Analog, RS-485 0 V ~ 5 V Female - 1/4 6.35mm NPT Threaded Vented Gauge 100PSI (689.48kPa) 300PSI (2068.43kPa)
PPT0005DFW5VB PPT0005DFW5VB Honeywell Aerospace
RFQ

Min: 1

Mult: 1

download -40°C~85°C 1 (Unlimited) Non-RoHS Compliant 2012 https://pdf.utmel.com/r/datasheets/honeywellaerospace-ppt0002grr5vb-datasheets-5875.pdf Module Cube 11 Weeks Industrial Automation 5.5V~30V ±0.05% Connector Analog, RS-485 0 V ~ 5 V Male - 0.13 3.18mm Tube Filter Barbed, Filtered 15 PSI Differential ±5PSI (±34.47kPa) ±15PSI (±103.42kPa)
PPTR0270AP5VD-R024 PPTR0270AP5VD-R024 Honeywell Aerospace
RFQ

Min: 1

Mult: 1

download PPTR -40°C~85°C Not Applicable Non-RoHS Compliant https://pdf.utmel.com/r/datasheets/honeywellaerospace-pptr0020ap2vb-datasheets-1402.pdf Cylinder Industrial Automation 6V~30V ±0.24% Cable Analog, RS-485 0 V ~ 5 V Female - 1/4 6.35mm NPT Threaded Absolute 270PSI (1861.58kPa) 810PSI (5584.75kPa)
PPT0010DWX5VB PPT0010DWX5VB Honeywell Aerospace
RFQ

Min: 1

Mult: 1

download -40°C~85°C 1 (Unlimited) Non-RoHS Compliant 2012 https://pdf.utmel.com/r/datasheets/honeywellaerospace-ppt0002grr5vb-datasheets-5875.pdf Module Cube 11 Weeks Industrial Automation 5.5V~30V ±0.05% Connector Analog, RS-485 0 V ~ 5 V Female - 1/8" 3.18mm Swagelok? Male - 0.13" 3.18mm Tube Barbed, Threaded 30 PSI Differential ±10PSI (±68.95kPa) ±30PSI (±206.84kPa)
PPTR0300AP5VB-R092 PPTR0300AP5VB-R092 Honeywell Aerospace
RFQ

Min: 1

Mult: 1

download PPTR -40°C~85°C Not Applicable Non-RoHS Compliant https://pdf.utmel.com/r/datasheets/honeywellaerospace-pptr0020ap2vb-datasheets-1402.pdf Cylinder Industrial Automation 6V~30V ±0.24% Connector Analog, RS-485 0 V ~ 5 V Female - 1/4 6.35mm NPT Threaded Absolute 300PSI (2068.43kPa) 900PSI (6205.28kPa)
PPT0020GXF5VB PPT0020GXF5VB Honeywell Aerospace
RFQ

Min: 1

Mult: 1

download -40°C~85°C 1 (Unlimited) Non-RoHS Compliant 2012 /files/honeywellaerospace-ppt0002grr5vb-datasheets-5875.pdf Module Cube 11 Weeks Industrial Automation 5.5V~30V ±0.05% Connector Analog, RS-485 0 V ~ 5 V Female - 1/8" 3.18mm Swagelok? Filter Filtered, Threaded 60 PSI Vented Gauge 20PSI (137.9kPa) 60PSI (413.69kPa)
PPTR0300GP5VD-R022 PPTR0300GP5VD-R022 Honeywell Aerospace
RFQ

Min: 1

Mult: 1

download PPTR -40°C~85°C Not Applicable Non-RoHS Compliant https://pdf.utmel.com/r/datasheets/honeywellaerospace-pptr0020ap2vb-datasheets-1402.pdf Cylinder Industrial Automation 6V~30V ±0.24% Cable Analog, RS-485 0 V ~ 5 V Female - 1/4 6.35mm NPT Threaded Vented Gauge 300PSI (2068.43kPa) 900PSI (6205.28kPa)
PPT0002DWX2VA-S223 PPT0002DWX2VA-S223 Honeywell Aerospace
RFQ

Min: 1

Mult: 1

download 1 (Unlimited) Non-RoHS Compliant 11 Weeks
PPTR0400GP2VD-R072 PPTR0400GP2VD-R072 Honeywell Aerospace
RFQ

Min: 1

Mult: 1

download PPTR -40°C~85°C Not Applicable Non-RoHS Compliant https://pdf.utmel.com/r/datasheets/honeywellaerospace-pptr0020ap2vb-datasheets-1402.pdf Cylinder Industrial Automation 6V~30V ±0.24% Cable Analog, RS-232 0 V ~ 5 V Female - 1/4 6.35mm NPT Threaded Vented Gauge 400PSI (2757.9kPa) 1200PSI (8273.71kPa)
PPT0001DRF2VB PPT0001DRF2VB Honeywell Aerospace
RFQ

Min: 1

Mult: 1

download -40°C~85°C 1 (Unlimited) Non-RoHS Compliant 2012 https://pdf.utmel.com/r/datasheets/honeywellaerospace-ppt0002grr5vb-datasheets-5875.pdf Module Cube 11 Weeks Industrial Automation 5.5V~30V ±0.05% Connector Analog, RS-232 0 V ~ 5 V Male - 0.13 3.18mm Tube Filter Barbed, Filtered 3 PSI Differential ±1PSI (±6.89kPa) ±3PSI (±20.68kPa)
PPTR0350GP5VB-R033 PPTR0350GP5VB-R033 Honeywell Aerospace
RFQ

Min: 1

Mult: 1

download PPTR -40°C~85°C Not Applicable Non-RoHS Compliant https://pdf.utmel.com/r/datasheets/honeywellaerospace-pptr0020ap2vb-datasheets-1402.pdf Cylinder Industrial Automation 6V~30V ±0.24% Connector Analog, RS-485 0 V ~ 5 V Female - 1/4 6.35mm NPT Threaded Vented Gauge 350PSI (2413.17kPa) 1050PSI (7239.5kPa)
PPT0001GWW2VB PPT0001GWW2VB Honeywell Aerospace
RFQ

Min: 1

Mult: 1

download -40°C~85°C 1 (Unlimited) Non-RoHS Compliant 2012 https://pdf.utmel.com/r/datasheets/honeywellaerospace-ppt0002grr5vb-datasheets-5875.pdf Module Cube 11 Weeks Industrial Automation 5.5V~30V ±0.05% Connector Analog, RS-232 0 V ~ 5 V Male - 0.13 3.18mm Tube Dual Barbed 3 PSI Vented Gauge 1PSI (6.89kPa) 3PSI (20.68kPa)

In Stock

Please send RFQ , we will respond immediately.