NorComp(4494)

Compare Image Name Manufacturer Pricing(USD) Quantity Weight(Kg) Size(LxWxH) Part Status Series Mount Mounting Type Operating Temperature Packaging Moisture Sensitivity Level (MSL) Termination Voltage - Rated RoHS Status Published Datasheet Current Rating Package / Case Length Height Voltage - Rated AC Color Lead Free Material Factory Lead Time REACH SVHC Pbfree Code Connector Type Number of Positions Gender MIL Conformance DIN Conformance IEC Conformance Filter Feature Mixed Contacts Option Empty Shell Contact Finish - Mating ECCN Code Contact Material Contact Plating Total Number of Contacts HTS Code Dielectric Material JESD-609 Code Feature Body Material Insulation Material Termination Type Number of Rows Insulation Shell Material Contact Finish Termination Plating Shell Finish UL Flammability Code Connector Style Contact Type Flange Feature Shell Size, Connector Layout Shell Material, Finish Note
170-015-273L000 170-015-273L000 NorComp
RFQ

Min: 1

Mult: 1

download 170 Free Hanging Free Hanging (In-Line) -50°C~125°C Tray Not Applicable Through Hole ROHS3 Compliant 2008 /files/norcompinc-170015273l000-datasheets-3303.pdf 5A 39.1mm 12.6mm Black Lead Free Metal 14 Weeks No SVHC Receptacle for Female Contacts 15 Receptacle NO NO NO NO NO GENERAL PURPOSE YES EAR99 Gold 15 8536.69.40.30 Polybutylene Terephthalate (PBT) e4 Steel 2 Chromate Tin 94V-0 D-Sub Signal Housing/Shell (Unthreaded) 2 DA A Steel, Nickel Plated Contacts Not Included
180-015-173L000 180-015-173L000 NorComp
RFQ

Min: 1

Mult: 1

download 180 Free Hanging Free Hanging (In-Line) -50°C~100°C Tray Not Applicable Crimp ROHS3 Compliant 2008 /files/norcompinc-180078172l000-datasheets-1445.pdf 2A 015 30.8mm 12.6mm Lead Free 14 Weeks No SVHC yes Plug for Male Contacts 15 Male Grounding Indents Steel 3 Nickel D-Sub, High Density Signal Housing/Shell (Unthreaded) 1 DE E High Density Steel, Nickel Plated Contacts Not Included
170-009-273L030 170-009-273L030 NorComp
RFQ

Min: 1

Mult: 1

download 170 Free Hanging Free Hanging (In-Line) -50°C~125°C Tray Not Applicable Crimp ROHS3 Compliant 2008 /files/norcompinc-170015273l000-datasheets-3303.pdf 30.8mm 12.6mm Black Lead Free 14 Weeks Receptacle for Female Contacts 9 Female NO NO NO NO NO GENERAL PURPOSE YES GOLD NOT SPECIFIED 9 Polybutylene Terephthalate (PBT) e4 2 D-Sub Signal Mating Side (4-40) 1 DE E Steel, Nickel Plated Contacts Not Included
180-015-272L010 180-015-272L010 NorComp
RFQ

Min: 1

Mult: 1

download 180 Free Hanging (In-Line) -50°C~100°C Tray 1 (Unlimited) ROHS3 Compliant 2008 /files/norcompinc-180078273l020-datasheets-1428.pdf 14 Weeks yes Receptacle for Female Contacts 15 NO NO NO NO NO GENERAL PURPOSE YES GOLD OVER NICKEL BRASS 15 e4 Shielded GLASS FILLED POLYBUTYLENE TEREPHTHALATE/NYLON66 CRIMP 3 Gold (Au) - with Nickel (Ni) barrier TIN 94V-0 D-Sub, High Density Signal Cable Side (4-40) 1 DE E High Density Steel, Tin Plated Contacts Not Included
170-015-273L020 170-015-273L020 NorComp
RFQ

Min: 1

Mult: 1

download 170 Free Hanging Free Hanging (In-Line) -50°C~125°C Tray Not Applicable Crimp ROHS3 Compliant 2008 /files/norcompinc-170015273l000-datasheets-3303.pdf 39.1mm 12.6mm Black Lead Free 14 Weeks Receptacle for Female Contacts 15 Female NO NO NO NO NO GENERAL PURPOSE YES NOT SPECIFIED EAR99 NOT SPECIFIED 15 8536.69.40.30 Polybutylene Terephthalate (PBT) 2 94V-0 D-Sub Signal Cable Side (4-40) 2 DA A Steel, Nickel Plated Contacts Not Included
170-037-272L000 170-037-272L000 NorComp
RFQ

Min: 1

Mult: 1

download 170 Free Hanging Free Hanging (In-Line) -50°C~125°C Tray Not Applicable ROHS3 Compliant 2008 /files/norcompinc-170015273l000-datasheets-3303.pdf Black 14 Weeks Receptacle for Female Contacts 37 Receptacle NO NO NO NO NO GENERAL PURPOSE YES NOT SPECIFIED EAR99 NOT SPECIFIED 37 8536.69.40.30 Polybutylene Terephthalate (PBT) CRIMP 2 TIN 94V-0 D-Sub Signal Housing/Shell (Unthreaded) 4 DC C Steel, Tin Plated Contacts Not Included
170-025-173L010 170-025-173L010 NorComp
RFQ

Min: 1

Mult: 1

download 170 Free Hanging Free Hanging (In-Line) -50°C~125°C Tray Not Applicable ROHS3 Compliant 2008 /files/norcompinc-170025173l000-datasheets-3229.pdf 53mm 12.6mm Lead Free 14 Weeks yes Plug for Male Contacts 25 Male Polybutylene Terephthalate (PBT), Glass Filled Grounding Indents 2 D-Sub Signal Cable Side (4-40) 3 DB B Steel, Nickel Plated Contacts Not Included
170-037-172L000 170-037-172L000 NorComp
RFQ

Min: 1

Mult: 1

download 170 Free Hanging Free Hanging (In-Line) -50°C~125°C Tray Not Applicable ROHS3 Compliant 2008 /files/norcompinc-170025173l000-datasheets-3229.pdf Black 15 Weeks Plug for Male Contacts 37 Male Polybutylene Terephthalate (PBT) 2 D-Sub Signal Housing/Shell (Unthreaded) 4 DC C Steel, Tin Plated Contacts Not Included
170-025-273L010 170-025-273L010 NorComp
RFQ

Min: 1

Mult: 1

download 170 Free Hanging Free Hanging (In-Line) -50°C~125°C Tray Not Applicable Crimp ROHS3 Compliant 2008 /files/norcompinc-170015273l000-datasheets-3303.pdf 53mm 12.6mm Black Lead Free 14 Weeks Receptacle for Female Contacts 25 Female NO NO NO NO NO GENERAL PURPOSE YES NOT SPECIFIED EAR99 NOT SPECIFIED 25 8536.69.40.30 Polybutylene Terephthalate (PBT) 2 94V-0 D-Sub Signal Cable Side (4-40) 3 DB B Steel, Nickel Plated Contacts Not Included
170-015-273L030 170-015-273L030 NorComp
RFQ

Min: 1

Mult: 1

download 170 Free Hanging Free Hanging (In-Line) -50°C~125°C Tray Not Applicable Crimp ROHS3 Compliant 2008 /files/norcompinc-170015273l000-datasheets-3303.pdf 39.1mm 12.6mm Black Lead Free 14 Weeks Receptacle for Female Contacts 15 Female NO NO NO NO NO GENERAL PURPOSE YES GOLD EAR99 BRASS 15 8536.69.40.30 Polybutylene Terephthalate (PBT) e4 2 94V-0 D-Sub Signal Mating Side (4-40) 2 DA A Steel, Nickel Plated Contacts Not Included
170-009-173L020 170-009-173L020 NorComp
RFQ

Min: 1

Mult: 1

download 170 Free Hanging Free Hanging (In-Line) -50°C~125°C Tray Not Applicable Crimp ROHS3 Compliant 2008 /files/norcompinc-170025173l000-datasheets-3229.pdf 30.8mm 12.6mm Lead Free 14 Weeks yes Plug for Male Contacts 9 Male Polybutylene Terephthalate (PBT), Glass Filled Grounding Indents 2 D-Sub Signal Cable Side (4-40) 1 DE E Steel, Nickel Plated Contacts Not Included
170-009-272L020 170-009-272L020 NorComp
RFQ

Min: 1

Mult: 1

download 170 Free Hanging Free Hanging (In-Line) -50°C~125°C Tray Not Applicable SMD/SMT ROHS3 Compliant 2008 /files/norcompinc-170015273l000-datasheets-3303.pdf Black 14 Weeks Receptacle for Female Contacts 9 Female NO NO NO NO NO GENERAL PURPOSE YES GOLD NOT SPECIFIED 9 Polybutylene Terephthalate (PBT) e4 2 TIN D-Sub Signal Cable Side (4-40) 1 DE E Steel, Tin Plated Contacts Not Included
170-009-273L020 170-009-273L020 NorComp
RFQ

Min: 1

Mult: 1

download 170 Free Hanging Free Hanging (In-Line) -50°C~125°C Tray Not Applicable Crimp ROHS3 Compliant 2008 /files/norcompinc-170015273l000-datasheets-3303.pdf 30.8mm 12.6mm Black Lead Free 14 Weeks Receptacle for Female Contacts 9 Receptacle NO NO NO NO NO GENERAL PURPOSE YES GOLD BRASS 9 Polybutylene Terephthalate (PBT) e4 2 D-Sub Signal Cable Side (4-40) 1 DE E Steel, Nickel Plated Contacts Not Included
180-015-272L000 180-015-272L000 NorComp
RFQ

Min: 1

Mult: 1

download 180 Free Hanging Free Hanging (In-Line) -50°C~100°C Tray 1 (Unlimited) Crimp 500V ROHS3 Compliant 2008 /files/norcompinc-180078273l020-datasheets-1428.pdf 5A 14 Weeks yes Receptacle for Female Contacts 15 Receptacle NO NO NO NO NO GENERAL PURPOSE YES EAR99 BRASS Gold 15 e4 Shielded Glass 3 Insulated Steel Tin TIN 94V-0 D-Sub, High Density Signal Housing/Shell (Unthreaded) 1 DE E High Density Steel, Tin Plated Contacts Not Included
170-037-173L010 170-037-173L010 NorComp
RFQ

Min: 1

Mult: 1

download 170 Free Hanging Free Hanging (In-Line) -50°C~125°C Tray Not Applicable Crimp ROHS3 Compliant 2008 /files/norcompinc-170025173l000-datasheets-3229.pdf 69.4mm 12.6mm Black Lead Free 14 Weeks yes Plug for Male Contacts 37 Male Polybutylene Terephthalate (PBT), Glass Filled Grounding Indents 2 D-Sub Signal Cable Side (4-40) 4 DC C Steel, Nickel Plated Contacts Not Included
180-015-273L000 180-015-273L000 NorComp
RFQ

Min: 1

Mult: 1

download 180 Free Hanging Free Hanging (In-Line) -50°C~100°C Tray Not Applicable Crimp ROHS3 Compliant 2008 /files/norcompinc-180078273l020-datasheets-1428.pdf 2A 015 30.8mm 12.6mm Lead Free 14 Weeks No SVHC yes Receptacle for Female Contacts 15 Receptacle NO NO NO NO NO GENERAL PURPOSE YES GOLD OVER NICKEL EAR99 BRASS 15 e4 Steel GLASS FILLED POLYBUTYLENE TEREPHTHALATE/NYLON66 3 Tin 94V-0 D-Sub, High Density Signal Housing/Shell (Unthreaded) 1 DE E High Density Steel, Nickel Plated Contacts Not Included
170-009-272L010 170-009-272L010 NorComp
RFQ

Min: 1

Mult: 1

download 170 Free Hanging Free Hanging (In-Line) -50°C~125°C Tray Not Applicable Crimp ROHS3 Compliant 2008 /files/norcompinc-170015273l000-datasheets-3303.pdf Black 14 Weeks Receptacle for Female Contacts 9 Female NO NO NO NO NO GENERAL PURPOSE YES GOLD NOT SPECIFIED 9 Polybutylene Terephthalate (PBT) e4 2 TIN D-Sub Signal Cable Side (4-40) 1 DE E Steel, Tin Plated Contacts Not Included
180-015-273L010 180-015-273L010 NorComp
RFQ

Min: 1

Mult: 1

download 180 Free Hanging Free Hanging (In-Line) -50°C~100°C Tray Not Applicable Crimp ROHS3 Compliant 2008 /files/norcompinc-180078273l020-datasheets-1428.pdf 2A 30.8mm 12.6mm 500V Lead Free 14 Weeks yes Receptacle for Female Contacts 15 Female NO NO NO NO NO GENERAL PURPOSE YES EAR99 BRASS 15 e4 GLASS FILLED POLYBUTYLENE TEREPHTHALATE/NYLON66 3 Nickel 94V-0 D-Sub, High Density Signal Cable Side (4-40) 1 DE E High Density Steel, Nickel Plated Contacts Not Included
180-026-172L000 180-026-172L000 NorComp
RFQ

Min: 1

Mult: 1

download 180 Free Hanging Free Hanging (In-Line) -50°C~100°C Tray 1 (Unlimited) ROHS3 Compliant 2008 /files/norcompinc-180078172l000-datasheets-1445.pdf 14 Weeks Plug for Male Contacts 26 Male NO NO NO NO NO GENERAL PURPOSE NO 26 Shielded POLYBUTYLENE TEREPHTHALATE CRIMP 3 TIN 94V-0 D-Sub, High Density Signal Housing/Shell (Unthreaded) 2 DA A High Density Steel, Tin Plated Contacts Not Included
170-015-272L000 170-015-272L000 NorComp
RFQ

Min: 1

Mult: 1

download 170 Free Hanging Free Hanging (In-Line) -50°C~125°C Tray Not Applicable Crimp ROHS3 Compliant 2008 /files/norcompinc-170015273l000-datasheets-3303.pdf Black 14 Weeks Receptacle for Female Contacts 15 Receptacle NO NO NO NO NO GENERAL PURPOSE YES NOT SPECIFIED EAR99 NOT SPECIFIED 15 8536.69.40.30 Polybutylene Terephthalate (PBT) 2 TIN 94V-0 D-Sub Signal Housing/Shell (Unthreaded) 2 DA A Steel, Tin Plated Contacts Not Included
170-009-173L010 170-009-173L010 NorComp
RFQ

Min: 1

Mult: 1

download 170 Free Hanging Free Hanging (In-Line) -50°C~125°C Tray Not Applicable Crimp ROHS3 Compliant 2008 /files/norcompinc-170025173l000-datasheets-3229.pdf 30.8mm 12.6mm Lead Free 14 Weeks yes Plug for Male Contacts 9 Male Polybutylene Terephthalate (PBT), Glass Filled Grounding Indents 2 D-Sub Signal Cable Side (4-40) 1 DE E Steel, Nickel Plated Contacts Not Included
180-062-173L000 180-062-173L000 NorComp
RFQ

Min: 1

Mult: 1

download 180 Free Hanging Free Hanging (In-Line) -50°C~100°C Tray Not Applicable Crimp ROHS3 Compliant 2005 /files/norcompinc-180078172l000-datasheets-1445.pdf 2A 69.4mm 15.4mm Lead Free 14 Weeks yes Plug for Male Contacts 62 Male Grounding Indents 3 Steel Nickel D-Sub, High Density Signal Housing/Shell (Unthreaded) 4 DC C High Density Steel, Nickel Plated Contacts Not Included
180-026-272L000 180-026-272L000 NorComp
RFQ

Min: 1

Mult: 1

download 180 Free Hanging Free Hanging (In-Line) -50°C~100°C Tray 1 (Unlimited) ROHS3 Compliant 2008 /files/norcompinc-180078273l020-datasheets-1428.pdf 14 Weeks yes Receptacle for Female Contacts 26 Receptacle NO NO NO NO NO GENERAL PURPOSE YES GOLD OVER NICKEL EAR99 BRASS 26 e4 Shielded GLASS FILLED POLYBUTYLENE TEREPHTHALATE/NYLON66 CRIMP 3 Gold (Au) - with Nickel (Ni) barrier TIN 94V-0 D-Sub, High Density Signal Housing/Shell (Unthreaded) 2 DA A High Density Steel, Tin Plated Contacts Not Included
170-009-172L020 170-009-172L020 NorComp
RFQ

Min: 1

Mult: 1

download 170 Free Hanging Free Hanging (In-Line) -50°C~125°C Tray Not Applicable ROHS3 Compliant 2008 /files/norcompinc-170025173l000-datasheets-3229.pdf Black 14 Weeks Plug for Male Contacts 9 Male Polybutylene Terephthalate (PBT) 2 D-Sub Signal Cable Side (4-40) 1 DE E Steel, Tin Plated Contacts Not Included
170-009-172L030 170-009-172L030 NorComp
RFQ

Min: 1

Mult: 1

download 170 Free Hanging Free Hanging (In-Line) -50°C~125°C Tray Not Applicable ROHS3 Compliant 2008 /files/norcompinc-170025173l000-datasheets-3229.pdf Black 14 Weeks Plug for Male Contacts 9 Male Polybutylene Terephthalate (PBT) 2 D-Sub Signal Mating Side (4-40) 1 DE E Steel, Tin Plated Contacts Not Included
170-015-173L010 170-015-173L010 NorComp
RFQ

Min: 1

Mult: 1

download 170 Free Hanging Free Hanging (In-Line) -50°C~125°C Tray Not Applicable Crimp ROHS3 Compliant 2008 /files/norcompinc-170025173l000-datasheets-3229.pdf 39.1mm 12.6mm Lead Free 14 Weeks yes Plug for Male Contacts 15 Male Polybutylene Terephthalate (PBT), Glass Filled Grounding Indents 2 D-Sub Signal Cable Side (4-40) 2 DA A Steel, Nickel Plated Contacts Not Included
170-015-272L010 170-015-272L010 NorComp
RFQ

Min: 1

Mult: 1

download 170 Free Hanging Free Hanging (In-Line) -50°C~125°C Tray Not Applicable ROHS3 Compliant 2008 /files/norcompinc-170015273l000-datasheets-3303.pdf Black 14 Weeks Receptacle for Female Contacts 15 Female NO NO NO NO NO GENERAL PURPOSE YES NOT SPECIFIED EAR99 NOT SPECIFIED 15 8536.69.40.30 Polybutylene Terephthalate (PBT) CRIMP 2 TIN 94V-0 D-Sub Signal Cable Side (4-40) 2 DA A Steel, Tin Plated Contacts Not Included
180-044-173L010 180-044-173L010 NorComp
RFQ

Min: 1

Mult: 1

download 180 Free Hanging Free Hanging (In-Line) -50°C~100°C Tray Not Applicable Crimp ROHS3 Compliant 2008 /files/norcompinc-180078172l000-datasheets-1445.pdf 2A 53mm 12.6mm 500V Lead Free 14 Weeks yes Plug for Male Contacts 44 Male Grounding Indents 3 Nickel D-Sub, High Density Signal Cable Side (4-40) 3 DB B High Density Steel, Nickel Plated Contacts Not Included
180-062-173L010 180-062-173L010 NorComp
RFQ

Min: 1

Mult: 1

download 180 Free Hanging Free Hanging (In-Line) -50°C~100°C Tray Not Applicable Crimp ROHS3 Compliant 2008 /files/norcompinc-180078172l000-datasheets-1445.pdf 2A 69.4mm 12.6mm 500V Lead Free 14 Weeks yes Plug for Male Contacts 62 Male Grounding Indents 3 Nickel D-Sub, High Density Signal Cable Side (4-40) 4 DC C High Density Steel, Nickel Plated Contacts Not Included
170-015-172L030 170-015-172L030 NorComp
RFQ

Min: 1

Mult: 1

download 170 Free Hanging Free Hanging (In-Line) -50°C~125°C Tray Not Applicable Crimp ROHS3 Compliant 2008 /files/norcompinc-170025173l000-datasheets-3229.pdf Black 14 Weeks Plug for Male Contacts 15 Male Polybutylene Terephthalate (PBT), Glass Filled 2 D-Sub Signal Mating Side (4-40) 2 DA A Steel, Tin Plated Contacts Not Included

In Stock

Please send RFQ , we will respond immediately.