NorComp(4494)

Compare Image Name Manufacturer Pricing(USD) Quantity Weight(Kg) Size(LxWxH) Part Status Series Mount Mounting Type Operating Temperature Packaging Moisture Sensitivity Level (MSL) Termination RoHS Status Published Datasheet Current Rating Color Factory Lead Time Ratings Pbfree Code Connector Type Number of Positions Contact Material Housing Material Ingress Protection Dielectric Material Feature Contact Form Number of Rows Wire Gauge Contact Finish Contact Finish Thickness Material Flammability Rating Connector Style Contact Type Flange Feature Shell Size, Connector Layout Shell Material, Finish Backset Spacing
671-025-103L021 671-025-103L021 NorComp
RFQ

Min: 1

Mult: 1

download Seal-D 671 Free Hanging, Panel Panel Mount -50°C~100°C Tray 1 (Unlimited) Solder Cup RoHS Compliant 2012 /files/norcompinc-780m44213r001-datasheets-2740.pdf 5A Black 12 Weeks Dust Tight, IP66, Water Resistant yes Plug, Male Pins 25 Brass PBT IP66 - Dust Tight, Water Resistant Polybutylene Terephthalate (PBT) Grounding Indents Stamped 2 20-28 AWG Gold Flash UL94 V-0 D-Sub Signal Cable Side (4-40) 3 DB B Steel, Nickel Plated
680-015-113R021 680-015-113R021 NorComp
RFQ

Min: 1

Mult: 1

download Seal-D 680 Through Hole Panel Mount, Through Hole -50°C~100°C Tray 1 (Unlimited) Solder RoHS Compliant 2012 /files/norcompinc-780m44213r001-datasheets-2740.pdf 5A 12 Weeks Dust Tight, IP66, Water Resistant yes Plug, Male Pins 15 Brass PBT IP66 - Dust Tight, Water Resistant Polybutylene Terephthalate (PBT) Grounding Indents Stamped 3 Gold Flash UL94 V-0 D-Sub, High Density Signal Board Side (4-40) 1 DE E High Density Steel, Nickel Plated
681-044-113R171 681-044-113R171 NorComp
RFQ

Min: 1

Mult: 1

download Seal-D 681 Through Hole Panel Mount, Through Hole, Right Angle -50°C~100°C Tray 1 (Unlimited) Solder RoHS Compliant 2012 /files/norcompinc-780m44213r001-datasheets-2740.pdf 2A Black 12 Weeks Dust Tight, IP66, Water Resistant yes Plug, Male Pins 44 Brass Nylon IP66 - Dust Tight, Water Resistant Polyamide (PA9T), Nylon 9T Ground Strap, Grounding Indents 3 Gold Flash UL94 V-0 D-Sub, High Density Signal Housing/Shell (4-40) 3 DB B High Density Steel, Nickel Plated 0.350 (8.89mm)
680-026-103L011 680-026-103L011 NorComp
RFQ

Min: 1

Mult: 1

download Seal-D 680 Free Hanging, Panel Panel Mount -50°C~100°C Tray 1 (Unlimited) Solder Cup RoHS Compliant 2012 /files/norcompinc-780m44213r001-datasheets-2740.pdf 5A 12 Weeks Dust Tight, IP66, Water Resistant yes Plug, Male Pins 26 Brass PBT IP66 - Dust Tight, Water Resistant Polybutylene Terephthalate (PBT) Grounding Indents Stamped 3 Gold Flash UL94 V-0 D-Sub, High Density Signal Cable Side (4-40) 2 DA A High Density Steel, Nickel Plated
671-015-113R021 671-015-113R021 NorComp
RFQ

Min: 1

Mult: 1

download Seal-D 671 Through Hole Panel Mount, Through Hole -50°C~100°C Tray 1 (Unlimited) Solder RoHS Compliant 2012 /files/norcompinc-780m44213r001-datasheets-2740.pdf 5A Black 12 Weeks Dust Tight, IP66, Water Resistant yes Plug, Male Pins 15 Brass Nylon IP66 - Dust Tight, Water Resistant Polyamide (PA9T), Nylon 9T Grounding Indents Stamped 2 Gold Flash UL94 V-0 D-Sub Signal Board Side (4-40) 2 DA A Steel, Nickel Plated
680-015-103L011 680-015-103L011 NorComp
RFQ

Min: 1

Mult: 1

download Seal-D 680 Free Hanging, Panel Panel Mount -50°C~100°C Tray 1 (Unlimited) Solder Cup RoHS Compliant 2012 /files/norcompinc-780m44213r001-datasheets-2740.pdf 5A 12 Weeks Dust Tight, IP66, Water Resistant yes Plug, Male Pins 15 Brass PBT IP66 - Dust Tight, Water Resistant Polybutylene Terephthalate (PBT) Grounding Indents Stamped 3 Gold Flash UL94 V-0 D-Sub, High Density Signal Cable Side (4-40) 1 DE E High Density Steel, Nickel Plated
671-015-113R031 671-015-113R031 NorComp
RFQ

Min: 1

Mult: 1

download Seal-D 671 Through Hole Panel Mount, Through Hole -50°C~100°C Tray 1 (Unlimited) Solder RoHS Compliant 2012 /files/norcompinc-780m44213r001-datasheets-2740.pdf 5A Black 12 Weeks Dust Tight, IP66, Water Resistant yes Plug, Male Pins 15 Brass Nylon IP66 - Dust Tight, Water Resistant Polyamide (PA9T), Nylon 9T Grounding Indents Stamped 2 Gold Flash UL94 V-0 D-Sub Signal Mating Side (4-40) 2 DA A Steel, Nickel Plated
671-025-103L011 671-025-103L011 NorComp
RFQ

Min: 1

Mult: 1

download Seal-D 671 Free Hanging, Panel Panel Mount -50°C~100°C Tray 1 (Unlimited) Solder Cup RoHS Compliant 2012 /files/norcompinc-780m44213r001-datasheets-2740.pdf 5A Black 12 Weeks Dust Tight, IP66, Water Resistant yes Plug, Male Pins 25 Brass PBT IP66 - Dust Tight, Water Resistant Polybutylene Terephthalate (PBT) Grounding Indents Stamped 2 20-28 AWG Gold Flash UL94 V-0 D-Sub Signal Cable Side (4-40) 3 DB B Steel, Nickel Plated
680-044-113R051 680-044-113R051 NorComp
RFQ

Min: 1

Mult: 1

download Seal-D 680 Through Hole Panel Mount, Through Hole -50°C~100°C Tray 1 (Unlimited) Solder RoHS Compliant 2012 /files/norcompinc-780m44213r001-datasheets-2740.pdf 5A 12 Weeks Dust Tight, IP66, Water Resistant yes Plug, Male Pins 44 Brass PBT IP66 - Dust Tight, Water Resistant Polybutylene Terephthalate (PBT) Board Lock, Grounding Indents Stamped 3 Gold Flash UL94 V-0 D-Sub, High Density Signal Board Side (4-40) 3 DB B High Density Steel, Nickel Plated
680-044-113R021 680-044-113R021 NorComp
RFQ

Min: 1

Mult: 1

download Seal-D 680 Through Hole Panel Mount, Through Hole -50°C~100°C Tray 1 (Unlimited) Solder RoHS Compliant 2012 /files/norcompinc-780m44213r001-datasheets-2740.pdf 5A 12 Weeks Dust Tight, IP66, Water Resistant yes Plug, Male Pins 44 Brass PBT IP66 - Dust Tight, Water Resistant Polybutylene Terephthalate (PBT) Grounding Indents Stamped 3 Gold Flash UL94 V-0 D-Sub, High Density Signal Board Side (4-40) 3 DB B High Density Steel, Nickel Plated
671-015-103L031 671-015-103L031 NorComp
RFQ

Min: 1

Mult: 1

download Seal-D 671 Free Hanging, Panel Panel Mount -50°C~100°C Tray 1 (Unlimited) Solder Cup RoHS Compliant 2012 /files/norcompinc-780m44213r001-datasheets-2740.pdf 5A Black 12 Weeks Dust Tight, IP66, Water Resistant yes Plug, Male Pins 15 Brass PBT IP66 - Dust Tight, Water Resistant Polybutylene Terephthalate (PBT) Grounding Indents Stamped 2 20-28 AWG Gold Flash UL94 V-0 D-Sub Signal Mating Side (4-40) 2 DA A Steel, Nickel Plated
682-015-113R171 682-015-113R171 NorComp
RFQ

Min: 1

Mult: 1

download Seal-D 682 Through Hole Panel Mount, Through Hole, Right Angle -55°C~105°C Tray 1 (Unlimited) Solder RoHS Compliant 2012 /files/norcompinc-780m44213r001-datasheets-2740.pdf 5A Black 12 Weeks Dust Tight, IP66, Water Resistant yes Plug, Male Pins 15 Brass Nylon IP66 - Dust Tight, Water Resistant Polyamide (PA9T), Nylon 9T Ground Strap, Grounding Indents 2 Gold Flash UL94 V-0 D-Sub Signal Housing/Shell (4-40) 2 DA A Steel, Nickel Plated 0.318 (8.08mm)
671-025-113R021 671-025-113R021 NorComp
RFQ

Min: 1

Mult: 1

download Seal-D 671 Through Hole Panel Mount, Through Hole -50°C~100°C Tray 1 (Unlimited) Solder RoHS Compliant 2012 /files/norcompinc-780m44213r001-datasheets-2740.pdf 5A Black 12 Weeks Dust Tight, IP66, Water Resistant yes Plug, Male Pins 25 Brass Nylon IP66 - Dust Tight, Water Resistant Polyamide (PA9T), Nylon 9T Grounding Indents Stamped 2 Gold Flash UL94 V-0 D-Sub Signal Board Side (4-40) 3 DB B Steel, Nickel Plated
681-026-113R171 681-026-113R171 NorComp
RFQ

Min: 1

Mult: 1

download Seal-D 681 Through Hole Panel Mount, Through Hole, Right Angle -50°C~100°C Tray 1 (Unlimited) Solder RoHS Compliant 2012 /files/norcompinc-780m44213r001-datasheets-2740.pdf 2A Black 12 Weeks Dust Tight, IP66, Water Resistant yes Plug, Male Pins 26 Brass Nylon IP66 - Dust Tight, Water Resistant Polyamide (PA9T), Nylon 9T Ground Strap, Grounding Indents 3 Gold Flash UL94 V-0 D-Sub, High Density Signal Housing/Shell (4-40) 2 DA A High Density Steel, Nickel Plated 0.350 (8.89mm)
680-026-113R021 680-026-113R021 NorComp
RFQ

Min: 1

Mult: 1

download Seal-D 680 Through Hole Panel Mount, Through Hole -50°C~100°C Tray 1 (Unlimited) Solder RoHS Compliant 2012 /files/norcompinc-780m44213r001-datasheets-2740.pdf 5A 12 Weeks Dust Tight, IP66, Water Resistant yes Plug, Male Pins 26 Brass PBT IP66 - Dust Tight, Water Resistant Polybutylene Terephthalate (PBT) Grounding Indents Stamped 3 Gold Flash UL94 V-0 D-Sub, High Density Signal Board Side (4-40) 2 DA A High Density Steel, Nickel Plated
671-009-113R031 671-009-113R031 NorComp
RFQ

Min: 1

Mult: 1

download Seal-D 671 Through Hole Panel Mount, Through Hole -50°C~100°C Tray 1 (Unlimited) Solder RoHS Compliant 2012 /files/norcompinc-780m44213r001-datasheets-2740.pdf 5A Black 12 Weeks Dust Tight, IP66, Water Resistant yes Plug, Male Pins 9 Brass Nylon IP66 - Dust Tight, Water Resistant Polyamide (PA9T), Nylon 9T Grounding Indents Stamped 2 Gold Flash UL94 V-0 D-Sub Signal Mating Side (4-40) 1 DE E Steel, Nickel Plated
683-015-113R171 683-015-113R171 NorComp
RFQ

Min: 1

Mult: 1

download Seal-D 683 Through Hole Panel Mount, Through Hole, Right Angle -55°C~105°C Tray 1 (Unlimited) Solder RoHS Compliant 2012 /files/norcompinc-780m44213r001-datasheets-2740.pdf 5A Black 12 Weeks Dust Tight, IP66, Water Resistant yes Plug, Male Pins 15 Brass Nylon IP66 - Dust Tight, Water Resistant Polyamide (PA9T), Nylon 9T Ground Strap, Grounding Indents 2 Gold Flash UL94 V-0 D-Sub Signal Housing/Shell (4-40) 2 DA A Steel, Nickel Plated 0.590 (14.99mm)
671-009-103L031 671-009-103L031 NorComp
RFQ

Min: 1

Mult: 1

download Seal-D 671 Free Hanging, Panel Panel Mount -50°C~100°C Tray 1 (Unlimited) Solder Cup RoHS Compliant 2012 /files/norcompinc-780m44213r001-datasheets-2740.pdf 5A Black 12 Weeks Dust Tight, IP66, Water Resistant yes Plug, Male Pins 9 Brass PBT IP66 - Dust Tight, Water Resistant Polybutylene Terephthalate (PBT) Grounding Indents Stamped 2 20-28 AWG Gold Flash UL94 V-0 D-Sub Signal Mating Side (4-40) 1 DE E Steel, Nickel Plated
680-044-113R031 680-044-113R031 NorComp
RFQ

Min: 1

Mult: 1

download Seal-D 680 Through Hole Panel Mount, Through Hole -50°C~100°C Tray 1 (Unlimited) Solder RoHS Compliant 2012 /files/norcompinc-780m44213r001-datasheets-2740.pdf 5A 12 Weeks Dust Tight, IP66, Water Resistant yes Plug, Male Pins 44 Brass PBT IP66 - Dust Tight, Water Resistant Polybutylene Terephthalate (PBT) Grounding Indents Stamped 3 Gold Flash UL94 V-0 D-Sub, High Density Signal Mating Side (4-40) 3 DB B High Density Steel, Nickel Plated
683-015-113R531 683-015-113R531 NorComp
RFQ

Min: 1

Mult: 1

download Seal-D 683 Through Hole Panel Mount, Through Hole, Right Angle -55°C~105°C Tray 1 (Unlimited) Solder RoHS Compliant 2012 /files/norcompinc-780m44213r001-datasheets-2740.pdf 5A Black 12 Weeks Dust Tight, IP66, Water Resistant yes Plug, Male Pins 15 Brass Nylon IP66 - Dust Tight, Water Resistant Polyamide (PA9T), Nylon 9T Board Lock, Grounding Indents 2 Gold Flash UL94 V-0 D-Sub Signal Housing/Shell (4-40) 2 DA A Steel, Nickel Plated 0.590 (14.99mm)
682-025-113R171 682-025-113R171 NorComp
RFQ

Min: 1

Mult: 1

download Seal-D 682 Through Hole Panel Mount, Through Hole, Right Angle -55°C~105°C Tray 1 (Unlimited) Solder RoHS Compliant 2012 /files/norcompinc-780m44213r001-datasheets-2740.pdf 5A Black 12 Weeks Dust Tight, IP66, Water Resistant yes Plug, Male Pins 25 Brass Nylon IP66 - Dust Tight, Water Resistant Polyamide (PA9T), Nylon 9T Ground Strap, Grounding Indents 2 Gold Flash UL94 V-0 D-Sub Signal Housing/Shell (4-40) 3 DB B Steel, Nickel Plated 0.318 (8.08mm)
671-025-103L031 671-025-103L031 NorComp
RFQ

Min: 1

Mult: 1

download Seal-D 671 Free Hanging, Panel Panel Mount -50°C~100°C Tray 1 (Unlimited) Solder Cup RoHS Compliant 2012 /files/norcompinc-780m44213r001-datasheets-2740.pdf 5A Black 12 Weeks Dust Tight, IP66, Water Resistant yes Plug, Male Pins 25 Brass PBT IP66 - Dust Tight, Water Resistant Polybutylene Terephthalate (PBT) Grounding Indents Stamped 2 20-28 AWG Gold Flash UL94 V-0 D-Sub Signal Mating Side (4-40) 3 DB B Steel, Nickel Plated
683-025-113R171 683-025-113R171 NorComp
RFQ

Min: 1

Mult: 1

download Seal-D 683 Through Hole Panel Mount, Through Hole, Right Angle -55°C~105°C Tray 1 (Unlimited) Solder RoHS Compliant 2012 /files/norcompinc-780m44213r001-datasheets-2740.pdf 5A Black 12 Weeks Dust Tight, IP66, Water Resistant yes Plug, Male Pins 25 Brass Nylon IP66 - Dust Tight, Water Resistant Polyamide (PA9T), Nylon 9T Ground Strap, Grounding Indents 2 Gold Flash UL94 V-0 D-Sub Signal Housing/Shell (4-40) 3 DB B Steel, Nickel Plated 0.590 (14.99mm)
671-015-113R011 671-015-113R011 NorComp
RFQ

Min: 1

Mult: 1

download Seal-D 671 Through Hole Panel Mount, Through Hole -50°C~100°C Tray 1 (Unlimited) Solder RoHS Compliant 2012 /files/norcompinc-780m44213r001-datasheets-2740.pdf 5A Black 12 Weeks Dust Tight, IP66, Water Resistant yes Plug, Male Pins 15 Brass Nylon IP66 - Dust Tight, Water Resistant Polyamide (PA9T), Nylon 9T Grounding Indents Stamped 2 Gold Flash UL94 V-0 D-Sub Signal Board Side (4-40) 2 DA A Steel, Nickel Plated
680-026-113R011 680-026-113R011 NorComp
RFQ

Min: 1

Mult: 1

download Seal-D 680 Through Hole Panel Mount, Through Hole -50°C~100°C Tray 1 (Unlimited) Solder RoHS Compliant 2012 /files/norcompinc-780m44213r001-datasheets-2740.pdf 5A 12 Weeks Dust Tight, IP66, Water Resistant yes Plug, Male Pins 26 Brass PBT IP66 - Dust Tight, Water Resistant Polybutylene Terephthalate (PBT) Grounding Indents Stamped 3 Gold Flash UL94 V-0 D-Sub, High Density Signal Board Side (4-40) 2 DA A High Density Steel, Nickel Plated
680-015-113R011 680-015-113R011 NorComp
RFQ

Min: 1

Mult: 1

download Seal-D 680 Through Hole Panel Mount, Through Hole -50°C~100°C Tray 1 (Unlimited) Solder RoHS Compliant 2012 /files/norcompinc-780m44213r001-datasheets-2740.pdf 5A 12 Weeks Dust Tight, IP66, Water Resistant yes Plug, Male Pins 15 Brass PBT IP66 - Dust Tight, Water Resistant Polybutylene Terephthalate (PBT) Grounding Indents Stamped 3 Gold Flash UL94 V-0 D-Sub, High Density Signal Board Side (4-40) 1 DE E High Density Steel, Nickel Plated
680-044-103L031 680-044-103L031 NorComp
RFQ

Min: 1

Mult: 1

download Seal-D 680 Free Hanging, Panel Panel Mount -50°C~100°C Tray 1 (Unlimited) Solder Cup RoHS Compliant 2012 /files/norcompinc-780m44213r001-datasheets-2740.pdf 5A 12 Weeks Dust Tight, IP66, Water Resistant yes Plug, Male Pins 44 Brass PBT IP66 - Dust Tight, Water Resistant Polybutylene Terephthalate (PBT) Grounding Indents Stamped 3 Gold Flash UL94 V-0 D-Sub, High Density Signal Mating Side (4-40) 3 DB B High Density Steel, Nickel Plated
683-009-113R531 683-009-113R531 NorComp
RFQ

Min: 1

Mult: 1

download Seal-D 683 Through Hole Panel Mount, Through Hole, Right Angle -55°C~105°C Tray 1 (Unlimited) Solder RoHS Compliant 2012 /files/norcompinc-780m44213r001-datasheets-2740.pdf 5A Black 12 Weeks Dust Tight, IP66, Water Resistant yes Plug, Male Pins 9 Brass Nylon IP66 - Dust Tight, Water Resistant Polyamide (PA9T), Nylon 9T Board Lock, Grounding Indents 2 Gold Flash UL94 V-0 D-Sub Signal Housing/Shell (4-40) 1 DE E Steel, Nickel Plated 0.590 (14.99mm)
671-025-113R031 671-025-113R031 NorComp
RFQ

Min: 1

Mult: 1

download Seal-D 671 Through Hole Panel Mount, Through Hole -50°C~100°C Tray 1 (Unlimited) Solder RoHS Compliant 2012 /files/norcompinc-780m44213r001-datasheets-2740.pdf 5A Black 12 Weeks Dust Tight, IP66, Water Resistant yes Plug, Male Pins 25 Brass Nylon IP66 - Dust Tight, Water Resistant Polyamide (PA9T), Nylon 9T Grounding Indents Stamped 2 Gold Flash UL94 V-0 D-Sub Signal Mating Side (4-40) 3 DB B Steel, Nickel Plated
671-015-103L011 671-015-103L011 NorComp
RFQ

Min: 1

Mult: 1

download Seal-D 671 Free Hanging, Panel Panel Mount -50°C~100°C Tray 1 (Unlimited) Solder Cup RoHS Compliant 2012 /files/norcompinc-780m44213r001-datasheets-2740.pdf 5A Black 12 Weeks Dust Tight, IP66, Water Resistant yes Plug, Male Pins 15 Brass PBT IP66 - Dust Tight, Water Resistant Polybutylene Terephthalate (PBT) Grounding Indents Stamped 2 20-28 AWG Gold Flash UL94 V-0 D-Sub Signal Cable Side (4-40) 2 DA A Steel, Nickel Plated

In Stock

Please send RFQ , we will respond immediately.