| Compare | Image | Name | Manufacturer | Pricing(USD) | Quantity | Weight(Kg) | Size(LxWxH) | Part Status | Type | Series | Mount | Mounting Type | Moisture Sensitivity Level (MSL) | Termination | RoHS Status | Published | Datasheet | Package / Case | Factory Lead Time | Tolerance | Termination Style | Circuit | Throw Configuration | Switching Cycles | Current Rating - AC | Switching Temperature | Reset Temperature | Current Rating - DC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| F20B110053600060 | Cantherm |
Min: 1 Mult: 1 |
download | F20 | Through Hole | Through Hole | Not Applicable | ROHS3 Compliant | /files/cantherm-f20b090053600060-datasheets-6670.pdf | 2-SIP, Potted | 5 Weeks | ±9°F ±5°C | Wire Leads - 4 (101.6mm) | SPST-NO | 7K | 1.6A 250V | 230°F 110°C | 176°F 80°C | ||||||||||
| F20B095053600060 | Cantherm |
Min: 1 Mult: 1 |
download | F20 | Through Hole | Through Hole | Not Applicable | ROHS3 Compliant | 2009 | /files/cantherm-f20b090053600060-datasheets-6670.pdf | 2-SIP, Potted | 5 Weeks | ±9°F ±5°C | Wire Leads - 4 (101.6mm) | SPST-NO | 7K | 1.6A 250V | 203°F 95°C | 149°F 65°C | |||||||||
| T22A14505DFFBG0E | Cantherm |
Min: 1 Mult: 1 |
download | T22 | Through Hole | Through Hole | 1 (Unlimited) | ROHS3 Compliant | /files/cantherm-t22a13005dffbg0e-datasheets-8609.pdf | Shrink Cap, Potted - Wire Leads | 5 Weeks | ±9°F ±5°C | Wire Leads - 4 (101.6mm) | SPST-NC | 10K | 3A 250V | 293°F 145°C | 240°F 115°C | ||||||||||
| F20B085053600060 | Cantherm |
Min: 1 Mult: 1 |
download | F20 | Through Hole | Through Hole | Not Applicable | ROHS3 Compliant | 2009 | /files/cantherm-f20b090053600060-datasheets-6670.pdf | 2-SIP, Potted | 5 Weeks | ±9°F ±5°C | Wire Leads - 4 (101.6mm) | SPST-NO | 7K | 1.6A 250V | 185°F 85°C | 131°F 55°C | |||||||||
| F20A16005DCFB06E | Cantherm |
Min: 1 Mult: 1 |
download | Mechanical | F20 | Through Hole | Through Hole | Not Applicable | Wire Leads | ROHS3 Compliant | 2009 | /files/cantherm-f20b090053600060-datasheets-6670.pdf | Housed Sensor | 5 Weeks | ±9°F ±5°C | Wire Leads - 4 (101.6mm) | SPST-NC | SPST | 7K | 1.6A 250V | 320°F 160°C | 266°F 130°C | ||||||
| CS705015Y | Cantherm |
Min: 1 Mult: 1 |
download | R53 | Chassis Mount | Chassis Mount | 1 (Unlimited) | ROHS3 Compliant | 2010 | /files/cantherm-cs706525z-datasheets-8425.pdf | Cylinder with Mounting Flange | 11 Weeks | ±9°F ±5°C | Quick Connect | SPST-NO | 100K | 10A 250V 15A 125V | 122°F 50°C | 10A 24V 15A 12V | |||||||||
| F20B100053600060 | Cantherm |
Min: 1 Mult: 1 |
download | F20 | Through Hole | Through Hole | Not Applicable | ROHS3 Compliant | /files/cantherm-f20b090053600060-datasheets-6670.pdf | 2-SIP, Potted | 5 Weeks | ±9°F ±5°C | Wire Leads - 4 (101.6mm) | SPST-NO | 7K | 1.6A 250V | 212°F 100°C | 158°F 70°C | ||||||||||
| MQT8K015XB | Cantherm |
Min: 1 Mult: 1 |
download | MQT | Chassis Mount | Chassis Mount | Not Applicable | ROHS3 Compliant | /files/cantherm-mqt8k005xbarb-datasheets-8673.pdf | Rectangular Case | 7 Weeks | ±5.4°F ±3°C | Wire Leads - 5.91 (150mm) | SPST-NC | 100K | 0.9A 250V 1.5A 125V | 59°F 15°C | 50°F 10.5°C | 0.3A 48V 1.5A 12V | |||||||||
| B12B07005AEDA0GE | Cantherm |
Min: 1 Mult: 1 |
download | B12 | Through Hole | Through Hole | Not Applicable | ROHS3 Compliant | /files/cantherm-b12a11525aefa0ge-datasheets-6629.pdf | Radial | 5 Weeks | ±9°F ±5°C | Wire Leads - 4 (101.6mm) | SPST-NO | 5K | 1.6A 250V | 158°F 70°C | 104°F 40°C | ||||||||||
| MQT8K020XB | Cantherm |
Min: 1 Mult: 1 |
download | MQT | Chassis Mount | Chassis Mount | Not Applicable | ROHS3 Compliant | /files/cantherm-mqt8k005xbarb-datasheets-8673.pdf | Rectangular Case | 7 Weeks | ±5.4°F ±3°C | Wire Leads - 5.91 (150mm) | SPST-NC | 100K | 0.9A 250V 1.5A 125V | 68°F 20°C | 50.9°F 15.5°C | 0.3A 48V 1.5A 12V | |||||||||
| T22A08505DFFBG0E | Cantherm |
Min: 1 Mult: 1 |
download | T22 | Through Hole | Through Hole | 1 (Unlimited) | ROHS3 Compliant | /files/cantherm-t22a13005dffbg0e-datasheets-8609.pdf | Shrink Cap, Potted - Wire Leads | 5 Weeks | ±9°F ±5°C | Wire Leads - 4 (101.6mm) | SPST-NC | 10K | 3A 250V | 185°F 85°C | 131°F 55°C | ||||||||||
| CS713025Z | Cantherm |
Min: 1 Mult: 1 |
download | R53 | Chassis Mount | Chassis Mount | 1 (Unlimited) | ROHS3 Compliant | /files/cantherm-cs706525z-datasheets-8425.pdf | Cylinder with Mounting Flange | 11 Weeks | ±9°F ±5°C | Quick Connect | SPST-NC | 100K | 10A 250V 15A 125V | 266°F 130°C | 10A 24V 15A 12V | ||||||||||
| A1014005 | Cantherm |
Min: 1 Mult: 1 |
download | Mechanical | A10V | Chassis Mount | Chassis Mount | 1 (Unlimited) | ROHS3 Compliant | 2009 | /files/cantherm-a1009005-datasheets-8629.pdf | Module | 5 Weeks | ±9°F ±5°C | User Defined | SPST-NC | SPST | 6K | 2.5A 250V | 284°F 140°C | ||||||||
| T22A16005DFFBG0E | Cantherm |
Min: 1 Mult: 1 |
download | T22 | Through Hole | Through Hole | 1 (Unlimited) | ROHS3 Compliant | 2009 | /files/cantherm-t22a13005dffbg0e-datasheets-8609.pdf | Shrink Cap, Potted - Wire Leads | 5 Weeks | ±9°F ±5°C | Wire Leads - 4 (101.6mm) | SPST-NC | 10K | 3A 250V | 320°F 160°C | 266°F 130°C | |||||||||
| A1007005 | Cantherm |
Min: 1 Mult: 1 |
download | Mechanical | A10V | Chassis Mount | Chassis Mount | 1 (Unlimited) | ROHS3 Compliant | 2009 | /files/cantherm-a1009005-datasheets-8629.pdf | Module | 5 Weeks | ±9°F ±5°C | User Defined | SPST-NC | SPST | 6K | 2.5A 250V | 158°F 70°C | ||||||||
| A1006505 | Cantherm |
Min: 1 Mult: 1 |
download | Mechanical | A10V | Chassis Mount | Chassis Mount | 1 (Unlimited) | ROHS3 Compliant | 2009 | /files/cantherm-a1009005-datasheets-8629.pdf | Module | 5 Weeks | ±9°F ±5°C | User Defined | SPST-NC | SPST | 6K | 2.5A 250V | 149°F 65°C | ||||||||
| CS709015Y | Cantherm |
Min: 1 Mult: 1 |
download | R53 | Chassis Mount | Chassis Mount | 1 (Unlimited) | ROHS3 Compliant | 2010 | /files/cantherm-cs706525z-datasheets-8425.pdf | Cylinder with Mounting Flange | 11 Weeks | ±9°F ±5°C | Quick Connect | SPST-NO | 100K | 10A 250V 15A 125V | 194°F 90°C | 10A 24V 15A 12V | |||||||||
| F20B14505ACFA06E | Cantherm |
Min: 1 Mult: 1 |
download | F20 | Through Hole | Through Hole | Not Applicable | ROHS3 Compliant | /files/cantherm-f20b090053600060-datasheets-6670.pdf | Potted - Wire Leads | 5 Weeks | ±9°F ±5°C | Wire Leads - 6 (152.4mm) | SPST-NO | 7K | 1.6A 250V | 293°F 145°C | 240°F 115°C | ||||||||||
| T22A10505DFFBG0E | Cantherm |
Min: 1 Mult: 1 |
download | T22 | Through Hole | Through Hole | 1 (Unlimited) | ROHS3 Compliant | 2009 | /files/cantherm-t22a13005dffbg0e-datasheets-8609.pdf | Shrink Cap, Potted - Wire Leads | 5 Weeks | ±9°F ±5°C | Wire Leads - 4 (101.6mm) | SPST-NC | 10K | 3A 250V | 221°F 105°C | 167°F 75°C | |||||||||
| CS704015Y | Cantherm |
Min: 1 Mult: 1 |
download | R53 | Chassis Mount | Chassis Mount | 1 (Unlimited) | ROHS3 Compliant | 2010 | /files/cantherm-cs706525z-datasheets-8425.pdf | Cylinder with Mounting Flange | 11 Weeks | ±9°F ±5°C | Quick Connect | SPST-NO | 100K | 10A 250V 15A 125V | 105°F 40°C | 10A 24V 15A 12V | |||||||||
| M3000XBARB | Cantherm |
Min: 1 Mult: 1 |
download | M3 | Chassis Mount | Chassis Mount | ROHS3 Compliant | 2010 | /files/cantherm-m3000xbarb-datasheets-1505.pdf | Rectangular Case | 5 Weeks | ±7.2°F ±4°C | SPST-NC | 7K | 3A 125V 5A 125V | 32°F 0°C | 23.9°F -4.5°C | 3A 24V 5A 12V | ||||||||||
| MQT8K025YB | Cantherm |
Min: 1 Mult: 1 |
download | MQT | Chassis Mount | Chassis Mount | Not Applicable | ROHS3 Compliant | /files/cantherm-mqt8k005xbarb-datasheets-8673.pdf | Rectangular Case | 7 Weeks | ±5.4°F ±3°C | Wire Leads - 5.91 (150mm) | SPST-NO | 100K | 0.9A 250V 1.5A 125V | 77°F 25°C | 68.9°F 20.5°C | 0.3A 48V 1.5A 12V | |||||||||
| MQT8K035YB | Cantherm |
Min: 1 Mult: 1 |
download | MQT | Chassis Mount | Chassis Mount | Not Applicable | ROHS3 Compliant | 2000 | /files/cantherm-mqt8k005xbarb-datasheets-8673.pdf | Rectangular Case | 5 Weeks | ±5.4°F ±3°C | Wire Leads - 5.91 (150mm) | SPST-NO | 100K | 0.9A 250V 1.5A 125V | 95°F 35°C | 86.9°F 30.5°C | 0.3A 48V 1.5A 12V | ||||||||
| H702S 350 | Cantherm |
Min: 1 Mult: 1 |
download | 1 (Unlimited) | ROHS3 Compliant | 2016 | 7 Weeks | |||||||||||||||||||||
| MQT8H 50XB | Cantherm |
Min: 1 Mult: 1 |
download | MQT | Free Hanging | Not Applicable | ROHS3 Compliant | /files/cantherm-mqt8k005xbarb-datasheets-8673.pdf | Rectangular Case | 7 Weeks | ±5.4°F ±3°C | Wire Leads - 5.91 (150mm) | SPST-NC | 100K | 0.9A 250V 1.5A 125V | 122°F 50°C | 114°F 45.5°C | 0.3A 48V 1.5A 12V | ||||||||||
| MQT8H 90XC | Cantherm |
Min: 1 Mult: 1 |
download | MQT | Free Hanging | Not Applicable | ROHS3 Compliant | /files/cantherm-mqt8k005xbarb-datasheets-8673.pdf | Rectangular Case | 7 Weeks | ±9°F ±5°C | Wire Leads - 5.91 (150mm) | SPST-NC | 100K | 1.3A 250V 2A 125V | 194°F 90°C | 182°F 83.5°C | 0.3A 48V 2A 12V | ||||||||||
| MQT8K 060XB2, 950L | Cantherm |
Min: 1 Mult: 1 |
download | Not Applicable | ROHS3 Compliant | 7 Weeks | ||||||||||||||||||||||
| F20A16005ACFA06E | Cantherm |
Min: 1 Mult: 1 |
download | F20 | Through Hole | Through Hole | Not Applicable | RoHS Compliant | 2009 | https://pdf.utmel.com/r/datasheets/cantherm-f20a16005acfa06e-datasheets-3512.pdf | Potted - Wire Leads | ±9°F ±5°C | Wire Leads - 6 (152.4mm) | SPST-NC | 7K | 1.6A 250V | 320°F 160°C | 266°F 130°C | ||||||||||
| B12A15005AEDA0GE | Cantherm |
Min: 1 Mult: 1 |
download | B12 | Through Hole | Through Hole | Not Applicable | Wire Leads | RoHS Compliant | /files/cantherm-b12a15005aeda0ge-datasheets-3532.pdf | Radial | ±9°F ±5°C | Wire Leads - 4 (101.6mm) | SPST-NC | SPST | 1K | 6A 250V | 302°F 150°C | 248°F 120°C | |||||||||
| F20A15005ACFA06E | Cantherm |
Min: 1 Mult: 1 |
download | F20 | Through Hole | Through Hole | Not Applicable | RoHS Compliant | /files/cantherm-f20a16005acfa06e-datasheets-3512.pdf | Potted - Wire Leads | ±9°F ±5°C | Wire Leads - 6 (152.4mm) | SPST-NC | 7K | 1.6A 250V | 302°F 150°C | 248°F 120°C |
Please send RFQ , we will respond immediately.