| Compare | Image | Name | Manufacturer | Pricing(USD) | Quantity | Weight(Kg) | Size(LxWxH) | Type | Series | Mounting Type | Operating Temperature | Frequency | Package / Case | Weight | Ingress Protection | Voltage - Supply | Number of Channels | Accuracy | Response Time | Sensitivity | Polarization | Termination Style | Output Type | Linearity | Display Type | Output | Sensor Type | Current - Supply (Max) | Panel Cutout Dimensions | For Measuring | Current - Sensing | Measuring Range | Number of Characters Per Row | Display Characters - Height | Features | Mfr |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| MGS-1800-1500 | Aim Dynamics |
Min: 1 Mult: 1 |
MGS | Chassis Mount | 0°C ~ 70°C | 40Hz ~ 3kHz | Module | 8V ~ 35VDC | 1 | ±1% | - | - | Unidirectional | - | Ratiometric, 4mA ~ 20mA | AC Single Phase/Three Phase | - | AC | 1500A | Aim Dynamics | ||||||||||||||||
| RCT16-1000 | Aim Dynamics |
Min: 1 Mult: 1 |
RCT | Free Hanging | -20°C ~ 70°C | 10Hz ~ 20kHz | Module, Single Pass Through | - | 1 | ±0.5% | - | - | - | - | - | Transformer w/Conditioning | - | AC | 1000A | Aim Dynamics | ||||||||||||||||
| SCT-2000-300 | Aim Dynamics |
Min: 1 Mult: 1 |
SCT | Free Hanging | -20°C ~ 75°C | 50Hz ~ 400Hz | Module, Single Pass Through | 600V | 1 | ±1% | - | - | Unidirectional | ±1% | Ratiometric, Voltage | Transformer w/Conditioning | - | AC | 300A | Aim Dynamics | ||||||||||||||||
| SCT-2000-1200 | Aim Dynamics |
Min: 1 Mult: 1 |
SCT | Free Hanging | -20°C ~ 75°C | 50Hz ~ 400Hz | Module, Single Pass Through | 600V | 1 | ±1% | - | - | Unidirectional | ±1% | Ratiometric, Voltage | Transformer w/Conditioning | - | AC | 1200A | Aim Dynamics | ||||||||||||||||
| SCT-1250-070 | Aim Dynamics |
Min: 1 Mult: 1 |
SCT | Free Hanging | -20°C ~ 70°C | 50Hz ~ 400Hz | Module, Single Pass Through | 600V | 1 | ±1% | - | - | Unidirectional | ±1% | Ratiometric, Voltage | Transformer w/Conditioning | - | AC | 70A | Aim Dynamics | ||||||||||||||||
| PM-BUNDLE-C200 | Aim Dynamics |
Min: 1 Mult: 1 |
Energy Monitor | - | DIN Rail | - | - | IP66/IP67 - Dust Tight, Water Resistant, Waterproof | - | - | - | LCD - Black Characters | - | 200A, 10 ~ 400V | 4 | - | Serial Communications Output | Aim Dynamics | ||||||||||||||||||
| PM-BUNDLE-D400 | Aim Dynamics |
Min: 1 Mult: 1 |
Energy Monitor | - | DIN Rail | - | - | IP66/IP67 - Dust Tight, Water Resistant, Waterproof | - | - | - | LCD - Black Characters | - | 400A, 10 ~ 400V | 4 | - | Serial Communications Output | Aim Dynamics | ||||||||||||||||||
| PM-BUNDLE-B50 | Aim Dynamics |
Min: 1 Mult: 1 |
Energy Monitor | - | DIN Rail | - | - | IP66/IP67 - Dust Tight, Water Resistant, Waterproof | - | - | - | LCD - Black Characters | - | 50A, 10 ~ 400V | 4 | - | Serial Communications Output | Aim Dynamics | ||||||||||||||||||
| MGS-1800-800 | Aim Dynamics |
Min: 1 Mult: 1 |
MGS | Chassis Mount | 0°C ~ 70°C | 40Hz ~ 3kHz | Module | 8V ~ 35VDC | 1 | ±1% | - | - | Unidirectional | - | Ratiometric, 4mA ~ 20mA | AC Single Phase/Three Phase | - | AC | 800A | Aim Dynamics | ||||||||||||||||
| PM-BUNDLE-B150 | Aim Dynamics |
Min: 1 Mult: 1 |
Energy Monitor | - | DIN Rail | - | - | IP66/IP67 - Dust Tight, Water Resistant, Waterproof | - | - | - | LCD - Black Characters | - | 150A, 10 ~ 400V | 4 | - | Serial Communications Output | Aim Dynamics | ||||||||||||||||||
| SCT-2000-1500 | Aim Dynamics |
Min: 1 Mult: 1 |
SCT | Free Hanging | -20°C ~ 75°C | 50Hz ~ 400Hz | Module, Single Pass Through | 600V | 1 | ±1% | - | - | Unidirectional | ±1% | Ratiometric, Voltage | Transformer w/Conditioning | - | AC | 1500A | Aim Dynamics | ||||||||||||||||
| SCT-3000-2500 | Aim Dynamics |
Min: 1 Mult: 1 |
SCT | Free Hanging | -20°C ~ 70°C | 50Hz ~ 400Hz | Module, Single Pass Through | 600V | 1 | ±1% | - | - | Unidirectional | ±1% | Ratiometric, Voltage | Transformer w/Conditioning | - | AC | 2500A | Aim Dynamics | ||||||||||||||||
| SCT-2000-1000 | Aim Dynamics |
Min: 1 Mult: 1 |
SCT | Free Hanging | -20°C ~ 75°C | 50Hz ~ 400Hz | Module, Single Pass Through | 600V | 1 | ±1% | - | - | Unidirectional | ±1% | Ratiometric, Voltage | Transformer w/Conditioning | - | AC | 1000A | Aim Dynamics | ||||||||||||||||
| SCT-1250-100 | Aim Dynamics |
Min: 1 Mult: 1 |
SCT | Free Hanging | -20°C ~ 70°C | 50Hz ~ 400Hz | Module, Single Pass Through | 600V | 1 | ±1% | - | - | Unidirectional | ±1% | Ratiometric, Voltage | Transformer w/Conditioning | - | AC | 100A | Aim Dynamics | ||||||||||||||||
| SCT-2000-000 | Aim Dynamics |
Min: 1 Mult: 1 |
SCT | Free Hanging | -20°C ~ 75°C | 50Hz ~ 400Hz | Module, Single Pass Through | 600V | 1 | ±1% | - | - | Unidirectional | ±1% | Ratiometric, Voltage | Transformer w/Conditioning | - | AC | 1500A | Aim Dynamics | ||||||||||||||||
| SCT-1250-200 | Aim Dynamics |
Min: 1 Mult: 1 |
SCT | Free Hanging | -20°C ~ 70°C | 50Hz ~ 400Hz | Module, Single Pass Through | 600V | 1 | ±1% | - | - | Unidirectional | ±1% | Ratiometric, Voltage | Transformer w/Conditioning | - | AC | 200A | Aim Dynamics | ||||||||||||||||
| RCT24-1000 | Aim Dynamics |
Min: 1 Mult: 1 |
RCT | Free Hanging | -20°C ~ 70°C | 10Hz ~ 20kHz | Module, Single Pass Through | - | 1 | ±0.5% | - | - | - | - | - | Transformer w/Conditioning | - | AC | 1000A | Aim Dynamics | ||||||||||||||||
| MGS-1800-2000 | Aim Dynamics |
Min: 1 Mult: 1 |
MGS | Chassis Mount | 0°C ~ 70°C | 40Hz ~ 3kHz | Module | 8V ~ 35VDC | 1 | ±1% | - | - | Unidirectional | - | Ratiometric, 4mA ~ 20mA | AC Single Phase/Three Phase | - | AC | 2000A | Aim Dynamics | ||||||||||||||||
| PM-BUNDLE-D200 | Aim Dynamics |
Min: 1 Mult: 1 |
Energy Monitor | - | DIN Rail | - | - | IP66/IP67 - Dust Tight, Water Resistant, Waterproof | - | - | - | LCD - Black Characters | - | 200A, 10 ~ 400V | 4 | - | Serial Communications Output | Aim Dynamics | ||||||||||||||||||
| PM-BUNDLE-D600 | Aim Dynamics |
Min: 1 Mult: 1 |
Energy Monitor | - | DIN Rail | - | - | IP66/IP67 - Dust Tight, Water Resistant, Waterproof | - | - | - | LCD - Black Characters | - | 600A, 10 ~ 400V | 4 | - | Serial Communications Output | Aim Dynamics | ||||||||||||||||||
| SCT-1250-250 | Aim Dynamics |
Min: 1 Mult: 1 |
SCT | Free Hanging | -20°C ~ 70°C | 50Hz ~ 400Hz | Module, Single Pass Through | 600V | 1 | ±1% | - | - | Unidirectional | ±1% | Ratiometric, Voltage | Transformer w/Conditioning | - | AC | 250A | Aim Dynamics | ||||||||||||||||
| SCT-1250-150 | Aim Dynamics |
Min: 1 Mult: 1 |
SCT | Free Hanging | -20°C ~ 70°C | 50Hz ~ 400Hz | Module, Single Pass Through | 600V | 1 | ±1% | - | - | Unidirectional | ±1% | Ratiometric, Voltage | Transformer w/Conditioning | - | AC | 150A | Aim Dynamics | ||||||||||||||||
| SCT-3000-3000 | Aim Dynamics |
Min: 1 Mult: 1 |
SCT | Free Hanging | -20°C ~ 70°C | 50Hz ~ 400Hz | Module, Single Pass Through | 600V | 1 | ±1% | - | - | Unidirectional | ±1% | Ratiometric, Voltage | Transformer w/Conditioning | - | AC | 3000A | Aim Dynamics | ||||||||||||||||
| SCT-3000-2000 | Aim Dynamics |
Min: 1 Mult: 1 |
SCT | Free Hanging | -20°C ~ 70°C | 50Hz ~ 400Hz | Module, Single Pass Through | 600V | 1 | ±1% | - | - | Unidirectional | ±1% | Ratiometric, Voltage | Transformer w/Conditioning | - | AC | 2000A | Aim Dynamics | ||||||||||||||||
| MGS-1800-5000 | Aim Dynamics |
Min: 1 Mult: 1 |
MGS | Chassis Mount | 0°C ~ 70°C | 40Hz ~ 3kHz | Module | 8V ~ 35VDC | 1 | ±1% | - | - | Unidirectional | - | Ratiometric, 4mA ~ 20mA | AC Single Phase/Three Phase | - | AC | 5000A | Aim Dynamics | ||||||||||||||||
| PM-BUNDLE-E1000 | Aim Dynamics |
Min: 1 Mult: 1 |
Energy Monitor | - | DIN Rail | - | - | IP66/IP67 - Dust Tight, Water Resistant, Waterproof | - | - | - | LCD - Black Characters | - | 5 ~ 50000A, 10 ~ 400V | 4 | - | Serial Communications Output | Aim Dynamics | ||||||||||||||||||
| SCT-3000-600 | Aim Dynamics |
Min: 1 Mult: 1 |
SCT | Free Hanging | -20°C ~ 70°C | 50Hz ~ 400Hz | Module, Single Pass Through | 600V | 1 | ±1% | - | - | Unidirectional | ±1% | Ratiometric, Voltage | Transformer w/Conditioning | - | AC | 600A | Aim Dynamics | ||||||||||||||||
| SCT-3000-1200 | Aim Dynamics |
Min: 1 Mult: 1 |
SCT | Free Hanging | -20°C ~ 70°C | 50Hz ~ 400Hz | Module, Single Pass Through | 600V | 1 | ±1% | - | - | Unidirectional | ±1% | Ratiometric, Voltage | Transformer w/Conditioning | - | AC | 1200A | Aim Dynamics | ||||||||||||||||
| SCT-1250-000 | Aim Dynamics |
Min: 1 Mult: 1 |
SCT | Free Hanging | -20°C ~ 70°C | 50Hz ~ 400Hz | Module, Single Pass Through | 600V | 1 | ±1% | - | - | Unidirectional | ±1% | Ratiometric, Current | Transformer w/Conditioning | - | AC | 800A | Aim Dynamics | ||||||||||||||||
| PM-BUNDLE-A30 | Aim Dynamics |
Min: 1 Mult: 1 |
Energy Monitor | - | DIN Rail | - | - | IP66/IP67 - Dust Tight, Water Resistant, Waterproof | - | - | - | LCD - Black Characters | - | 30A, 10 ~ 400V | 4 | - | Serial Communications Output | Aim Dynamics |
Please send RFQ , we will respond immediately.