| Compare | Image | Name | Manufacturer | Pricing(USD) | Quantity | Weight(Kg) | Size(LxWxH) | Part Status | Series | Mount | Mounting Type | Packaging | Moisture Sensitivity Level (MSL) | Termination | Max Operating Temperature | Min Operating Temperature | Voltage - Rated | RoHS Status | Published | Datasheet | Voltage - Rated DC | Current Rating | Diameter | Package / Case | Length | Height | Width | Operating Supply Voltage | Color | Lead Free | Material | Depth | Factory Lead Time | Weight | Approval Agency | REACH SVHC | Outside Diameter | Lifecycle Status | Pbfree Code | Connector Type | Gender | MIL Conformance | DIN Conformance | IEC Conformance | Filter Feature | Mixed Contacts | Option | ELV | Sealable | Thickness | Diameter - Inside | Orientation | ECCN Code | Contact Material | Contact Plating | Total Number of Contacts | Radiation Hardening | Body/Shell Style | HTS Code | Wire/Cable Gauge | JESD-609 Code | Feature | Reference Standard | Operating Temperature (Min) | Subcategory | Body Material | Insulation Material | Body Breadth | Terminal and Terminal Block Type | Body Plating | Number of Rows | Wire Gauge | Wire Cross Section | Wire Gauge (Max) | Wire Gauge (Min) | Terminal Type | Number of Conductors | Terminal Gender | Insulation | Insulation Diameter | Plating | Insulated Wire Support | Reliability | Number Of PCB Rows | PCB Contact Pattern | Contact Style | Mating Contact Pitch | Contact Pattern | Mating Contact Row Spacing | Mounting Option 1 | Rated Current (Signal) | Insulator Color | Plating Thickness | Mounting Option 2 | Heavy Duty | Polarization Key | Insertion Force-Max | Material Thickness | Government Qualified | Number of Wire Entries |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| SG-G POUCH | Artery |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Bulk | 1 (Unlimited) | Twist On | RoHS Compliant | /files/3m-sggpouch-datasheets-7640.pdf | Green | 4 Weeks | Copper Wire Only | 10-14 AWG | Wire Nut, Wing | Fully Insulated | Varies by Wire Size | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| PSN12-D | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2012 | 7.11mm | 21.08mm | Yellow | 7.11mm | 4 Weeks | Straight | EAR99 | 8536.90.40.00 | Copper Wire Only | Brass | Nylon | WIRE TERMINAL | Tin | 12-14 AWG | 14 AWG | 12 AWG | Inline, Individual Openings (Parallel) | FEMALE | Fully Insulated | 2 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 8-35115-1 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 2004 | 300V | 17.27mm | Natural | Not Applicable | 8.71mm | 17 Weeks | Unknown | ACTIVE (Last Updated: 2 days ago) | Female | Compliant | Straight | EAR99 | 8536.90.40.00 | 14 AWG | Copper | Nylon | WIRE TERMINAL | Tin | 14-22 AWG | 2.62 mm2 | 14 AWG | 22 AWG | Butt Splice, Closed End, Single Opening | Fully Insulated | 6.35 mm | No | 1 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| BSV18X-E | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2009 | /files/panduit-bsv18xe-datasheets-3038.pdf | Red | 4 Weeks | No | Brazed Seam | Vinyl | 18-22 AWG | 22 AWG | 18 AWG | Butt Splice, Inline, Individual Openings | Fully Insulated | 2 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 8-34071-1 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Plasti-Grip | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 2003 | /files/teconnectivityampconnectors-8340711-datasheets-7597.pdf | 1.065mm | 600V | Blue | Lead Free | 11 Weeks | Unknown | ACTIVE (Last Updated: 1 day ago) | yes | Female | Compliant | Straight | EAR99 | 8536.90.40.00 | Serrated Mating Area | Copper | Vinyl | WIRE TERMINAL | Tin | 14-16 AWG | 16 AWG | 14 AWG | Butt Splice, Inline, Individual Openings | Fully Insulated | 4.318 mm | Yes | No | 2 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 562-BOX | Artery |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Scotchlok™ | Box | Bulk | 1 (Unlimited) | IDC | 600V | RoHS Compliant | 2005 | /files/3m-562box-datasheets-7649.pdf | 4.8mm | 100 | 21mm | Yellow | 3 Weeks | 3.810176kg | 500μm | Brass | Tin | 10 AWG | Flame Retardant, Hinged Lid(s) | PP | 10-12 AWG | 12 AWG | 10 AWG | Inline, Tap (Suitcase) | Fully Insulated | 2 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 8-328730-1 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Bulk | 1 (Unlimited) | Crimp | 600V | RoHS Compliant | 2004 | /files/teconnectivityampconnectors-83287301-datasheets-7601.pdf | 18.288mm | 600V | Natural | Not Applicable | 11.58mm | 17 Weeks | No SVHC | 11.582 mm | ACTIVE (Last Updated: 3 days ago) | yes | Female | Compliant | EAR99 | 8536.90.40.00 | -10 AWG | Copper | Nylon | WIRE TERMINAL | Tin | 10-22 AWG | 6 mm2 | 22 AWG | 10 AWG | Butt Splice, Closed End, Single Opening | Fully Insulated | 9.53 mm | No | 1 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| PSCBRN-L | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2001 | Brown | 4 Weeks | EAR99 | 8536.90.40.00 | WIRE TERMINAL | Tin | 4-12 AWG | 12 AWG | 4 AWG | Inline, Individual Openings (Parallel) | Non-Insulated | 2 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ES18B-L | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | StrongHold™ | Bulk | Not Applicable | Crimp | ROHS3 Compliant | /files/panduitcorp-es18bl-datasheets-7605.pdf | 6 Weeks | Butted Seam, Serrated Mating Area | 18-22 AWG | Butt Splice, Inline, Individual Openings | Non-Insulated | 2 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| SCMS10-C | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2011 | /files/panduitcorp-scms10c-datasheets-7662.pdf | 50A | 30mm | Copper | 6.2mm | 4 Weeks | 408.229986g | EAR99 | 8536.90.40.00 | WIRE TERMINAL | Tin | 10mm2 | Butt Splice, Inline, Individual Openings | Non-Insulated | 2 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| SG-B POUCH | Artery |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Bulk | 1 (Unlimited) | Twist On | RoHS Compliant | /files/3m-sgbpouch-datasheets-7608.pdf | Blue | 3 Weeks | Copper Wire Only | 6-14 AWG | Wire Nut, Wing | Fully Insulated | Varies by Wire Size | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| PSN12-L | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2012 | 7.11mm | 21.08mm | Yellow | 7.11mm | 4 Weeks | Straight | EAR99 | 8536.90.40.00 | Copper Wire Only | Brass | Nylon | WIRE TERMINAL | Tin | 12-14 AWG | 14 AWG | 12 AWG | Inline, Individual Openings (Parallel) | FEMALE | Fully Insulated | 2 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| MVU10BCX | Artery |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Scotchlok™ | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 2013 | /files/3m-ma250dmmfk-datasheets-3277.pdf | Yellow | 3 Weeks | 24.493988g | -10 AWG | 10-12 AWG | 12 AWG | 10 AWG | Butt Splice, Inline, Individual Openings | Fully Insulated | 2 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 324471 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Ampower | BOARD | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 2005 | /files/teconnectivityampconnectors-324471-datasheets-7670.pdf | 3.27mm | Lead Free | Copper | 16 Weeks | 43.0276 mm | ACTIVE (Last Updated: 5 days ago) | yes | BOARD CONNECTOR | Female | NO | NO | NO | NO | NO | GENERAL PURPOSE | Compliant | No | Straight | Tin | 75 | RECEPTACLE | e3 | UL | -65°C | Headers and Edge Type Connectors | 0.48 inch | 3 | 1000MCM (kcmil) | Butt Splice, Inline, Individual Openings | ONE | Non-Insulated | COMMERCIAL | 3 | RECTANGULAR | SQ PIN-SKT | 0.1 inch | RECTANGULAR | 0.1 inch | HOLE .099-.111 | 3A | BLACK | 30μin | LOCKING | POLARIZED HOUSING | .5004 N | 2 | |||||||||||||||||||||||||||||||||||||||||
| BSV14Q | Artery |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Highland™ | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 2002 | /files/3m-ma250dmmfk-datasheets-3277.pdf | 25.4mm | 114.3mm | 139.7mm | Blue | 3 Weeks | 317.514659g | CSA, UL | 762μm | Straight | Copper | Tin | 14 AWG | Vinyl | 14-16 AWG | 16 AWG | 14 AWG | Butt Splice, Inline, Individual Openings | Fully Insulated | 2 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 8-321519-1 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Bulk | 1 (Unlimited) | Crimp | 600V | RoHS Compliant | 2009 | /files/teconnectivityampconnectors-83215191-datasheets-7560.pdf | 600V | Purple | 20 Weeks | No SVHC | ACTIVE (Last Updated: 22 hours ago) | Female | Compliant | No | EAR99 | Copper | Tin | 8536.90.40.00 | 10 AWG | PVC | WIRE TERMINAL | 10-22 AWG | 6.59 mm2 | Butt Splice, Closed End, Single Opening | Fully Insulated | 1 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 8-34067-1 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Plasti-Grip | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 2006 | /files/teconnectivityamp-8340671-datasheets-2979.pdf | Red | Lead Free | 16 Weeks | Unknown | ACTIVE (Last Updated: 4 days ago) | yes | Compliant | No | Straight | EAR99 | Copper | Tin | 8536.90.40.00 | 22 AWG | Vinyl | WIRE TERMINAL | 16-22 AWG | 16 AWG | 22 AWG | Butt Splice, Inline, Individual Openings | FEMALE | Fully Insulated | 3.05 mm | 2 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 8-36964-1 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Bulk | 1 (Unlimited) | Crimp | 300V | RoHS Compliant | 2004 | /files/teconnectivityampconnectors-8369641-datasheets-7567.pdf | 300V | 21.21mm | Purple | Lead Free | 22 Weeks | No SVHC | ACTIVE (Last Updated: 2 days ago) | yes | Compliant | Straight | EAR99 | 8536.90.40.00 | 22 AWG | Copper | PVC | WIRE TERMINAL | Tin | 14-22 AWG | 2 mm2 | 22 AWG | 14 AWG | Butt Splice, Closed End, Single Opening | FEMALE | Fully Insulated | 4.75 mm | No | 1 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 603504-2 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Sealed | Bulk | 1 (Unlimited) | Crimp | 125°C | -55°C | RoHS Compliant | 2007 | /files/teconnectivityampconnectors-6035042-datasheets-7516.pdf | 47.498mm | 600V | Yellow | Not Applicable | 16 Weeks | No SVHC | 6.35 mm | ACTIVE (Last Updated: 2 days ago) | Compliant | Yes | 2.921 mm | EAR99 | 8536.90.40.00 | 10 AWG | Copper | Nylon | WIRE TERMINAL | Tin | 10-12 AWG | 12 AWG | 10 AWG | Butt Splice, Inline, Individual Openings | FEMALE | Fully Insulated Heat Shrink | 6.1 mm | No | 2 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| BSN14-E | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2009 | https://pdf.utmel.com/r/datasheets/panduitcorp-bsn14c-datasheets-7138.pdf | Blue | 4 Weeks | No | Brazed Seam | 14-16 AWG | 16 AWG | 14 AWG | Butt Splice, Inline, Individual Openings | Fully Insulated | 2 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| SG-SAMPLE | Artery |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Bulk | 1 (Unlimited) | Twist On | RoHS Compliant | Multiple | 3 Weeks | Copper Wire Only | Wire Nut, Wing | Fully Insulated | Varies by Wire Size | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| J216-410-D | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2001 | 15.74mm | 9.14mm | 4 Weeks | No | 10-16 AWG | 16 AWG | 10 AWG | Butt Splice, Closed End, Single Opening | Non-Insulated | 1 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| BSV18Q | Artery |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Highland™ | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 2002 | /files/3m-ma250dmmfk-datasheets-3277.pdf | 25.4mm | 6.35mm | 107.95mm | Red | 3 Weeks | 317.514659g | CSA, UL | Unknown | 762μm | Straight | Copper | Tin | -18 AWG | Vinyl | 18-22 AWG | 22 AWG | 18 AWG | Butt Splice, Inline, Individual Openings | Fully Insulated | 2 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 8-31819-1 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Solistrand | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 2004 | /files/teconnectivityampconnectors-8318191-datasheets-7578.pdf | 14.4mm | Not Applicable | 4 Weeks | 4.191 mm | ACTIVE (Last Updated: 4 days ago) | yes | Compliant | 2.16 mm | Straight | EAR99 | Copper | Tin | 8536.90.40.00 | Brazed Seam, Serrated Mating Area | WIRE TERMINAL | 14-16 AWG | 16 AWG | 14 AWG | Butt Splice, Inline, Individual Openings | Non-Insulated | No | 840μm | 2 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| SG-Y POUCH | Artery |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Bulk | 1 (Unlimited) | Twist On | RoHS Compliant | /files/3m-sgypouch-datasheets-7524.pdf | Yellow | 3 Weeks | Copper Wire Only | 10-18 AWG | Wire Nut, Wing | Fully Insulated | Varies by Wire Size | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 8-34072-1 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Plasti-Grip | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 2006 | /files/teconnectivityampconnectors-8340721-datasheets-7583.pdf | 29.46mm | 600V | Yellow | Not Applicable | 20 Weeks | Unknown | ACTIVE (Last Updated: 5 days ago) | yes | Female | Compliant | Straight | EAR99 | 8536.90.40.00 | 10 AWG | Serrated Mating Area | Copper | Vinyl | WIRE TERMINAL | Tin | 10-12 AWG | 10 AWG | 12 AWG | Butt Splice, Inline, Individual Openings | Fully Insulated | 5.84 mm | No | 2 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 0192050008 | Molex |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | VersaKrimp | Bulk | 1 (Unlimited) | Crimp | ROHS3 Compliant | /files/molex-0192050008-datasheets-7527.pdf | 4 Weeks | 2 AWG | Inline, Individual Openings (Parallel) | Non-Insulated | Varies by Wire Size | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 8-32151-2 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Solistrand | Bulk | 1 (Unlimited) | Crimp | 0°C | RoHS Compliant | 1998 | /files/teconnectivityamp-8321512-datasheets-2996.pdf | 14.35mm | Yellow | Not Applicable | 5.74mm | 15 Weeks | 5.7404 mm | ACTIVE (Last Updated: 3 days ago) | yes | Female | Compliant | 3.28 mm | Straight | EAR99 | 8536.90.40.00 | Brazed Seam, Serrated Mating Area | Copper | WIRE TERMINAL | 10-12 AWG | 12 AWG | 10 AWG | Butt Splice, Inline, Individual Openings | Non-Insulated | Tin | No | 1.07mm | 2 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| SG-T POUCH | Artery |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Bulk | 1 (Unlimited) | Twist On | RoHS Compliant | /files/3m-sgtpouch-datasheets-7532.pdf | Tan | 4 Weeks | Copper Wire Only | 8-22 AWG | Wire Nut, Wing | Fully Insulated | Varies by Wire Size | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| MVU14BCX | Artery |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Scotchlok™ | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 2002 | /files/3m-ma250dmmfk-datasheets-3277.pdf | 25.4mm | Blue | 3 Weeks | 816.466266g | CSA, UL | 762μm | Straight | Copper | Tin | -14 AWG | Vinyl | 14-16 AWG | 16 AWG | 14 AWG | Butt Splice, Inline, Individual Openings | Fully Insulated | 2 |
Please send RFQ , we will respond immediately.