Compare | Image | Name | Manufacturer | Pricing(USD) | Quantity | Weight(Kg) | Size(LxWxH) | Part Status | Series | Mount | Mounting Type | Packaging | Moisture Sensitivity Level (MSL) | Termination | Voltage - Rated | RoHS Status | Published | Datasheet | Diameter | Package / Case | Length | Height | Width | Voltage - Rated AC | Color | Lead Free | Material | Depth | Factory Lead Time | Weight | Approval Agency | REACH SVHC | Lifecycle Status | Pbfree Code | Connector Type | Gender | ELV | Thickness | Diameter - Inside | Orientation | ECCN Code | Contact Material | Contact Plating | Radiation Hardening | HTS Code | Wire/Cable Gauge | Feature | Body Material | Length - Termination | Terminal and Terminal Block Type | Body Plating | Wire Gauge | Wire Cross Section | Wire Gauge (Max) | Wire Gauge (Min) | Terminal Type | Length - Overall | Wire/Cable Diameter | Terminal Material | Terminal Gender | Insulation | Insulation Diameter | Insulated Wire Support | Contact Finish | Plating Thickness | Heavy Duty | Stud Diameter | Material Thickness | Material - Insulation | Stud/Tab Size | Stud Size | Width - Outer Edges | Tongue Thickness | Tongue Inside Opening | Length - Ring Center to Termination |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
P18-10FN-C | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2011 | https://pdf.utmel.com/r/datasheets/panduitcorp-p186fnm-datasheets-9611.pdf | 3.56mm | 18.03mm | 7.87mm | Red | 7.87mm | 4 Weeks | 77.110703g | 1.78 mm | EAR99 | Copper | No | 8536.90.40.00 | Brazed Seam | FORK TERMINAL | 16-22 AWG | 18 AWG | 22 AWG | Standard | 0.710 18.03mm | FEMALE | Non-Insulated | Tin | 10 Stud | 0.310 7.87mm | 0.200 (5.08mm) | ||||||||||||||||||||||||||||||||||||
PN22-6F-M | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2001 | /files/panduitcorp-pn226fm-datasheets-2860.pdf | 19.56mm | 6.35mm | Yellow | Brass | 6.35mm | 4 Weeks | EAR99 | Copper | Tin | No | 8536.90.40.00 | FORK TERMINAL | 22-26 AWG | 22 AWG | 26 AWG | Standard | 0.770 19.56mm | Insulated | 0.090 (2.29mm) | Polyamide (PA), Nylon | 6 Stud | 0.250 6.35mm | 0.150 (3.81mm) | ||||||||||||||||||||||||||||||||||||||
P14-8FF-C | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2002 | https://pdf.utmel.com/r/datasheets/panduitcorp-p148ffc-datasheets-2805.pdf | 18.288mm | 7.874mm | 7.11mm | 4 Weeks | 95.254398g | EAR99 | Copper | Tin | No | 8536.90.40.00 | Brazed Seam, Serrated Termination | FORK TERMINAL | 14-16 AWG | 16 AWG | 14 AWG | Flanged | 0.720 18.29mm | FEMALE | Non-Insulated | 8 Stud | 0.310 7.87mm | 0.173 (4.39mm) | |||||||||||||||||||||||||||||||||||||||
0191410056 | Molex |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Krimptite | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | ROHS3 Compliant | /files/molex-0191410056-datasheets-2808.pdf | 5 Weeks | yes | EAR99 | Copper | 8536.90.40.00 | 0.165 4.19mm | FORK TERMINAL | 14-16 AWG | 2 mm2 | Standard | 0.564 14.33mm | Non-Insulated | Electro-Tin | 6 Stud | 0.295 7.49mm | 0.146 (3.71mm) | 0.211 5.36mm | ||||||||||||||||||||||||||||||||||||||||||||||
0191210009 | Molex |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | InsulKrimp | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | ROHS3 Compliant | /files/molex-0190540222-datasheets-5673.pdf | Red | 24 Weeks | yes | EAR99 | Copper | 8536.90.40.00 | 0.400 10.16mm | FORK TERMINAL | 18-22 AWG | 1.5 mm2 | Flanged | 0.781 19.84mm | Insulated | 0.145 (3.68mm) | Electro-Tin | Poly-Vinyl Chloride (PVC) | 10 Stud | 0.301 7.65mm | 0.198 (5.03mm) | 0.207 5.26mm | |||||||||||||||||||||||||||||||||||||||||||
52942 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | PIDG | Free Hanging | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 1999 | /files/teconnectivityampconnectors-529421-datasheets-1712.pdf | 26.7208mm | 9.53mm | 300V | Yellow | Lead Free | 9.53mm | 4 Weeks | Unknown | ACTIVE (Last Updated: 3 days ago) | yes | Female | Compliant | 6.4262 mm | Straight | EAR99 | Phosphor Bronze | Tin | 8536.90.40.00 | -10 AWG | Serrated Termination | Bronze | 0.601 15.27mm | WIRE TERMINAL | 10-12 AWG | 12 AWG | 10 AWG | Spring, Snap | 1.052 26.72mm | 6.35 mm | Insulated | 0.150 ~ 0.250 (3.81mm ~ 6.35mm) | Yes | No | 4.17 mm | Polyamide (PA), Nylon | 8 Stud | M4 | 0.375 9.53mm | 990μm | 0.164 (4.17mm) | 0.276 7.01mm | ||||||||||||||||||||
P18-8LF-C | Panduit Corp | $0.59 |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2004 | https://pdf.utmel.com/r/datasheets/panduitcorp-p188lfc-datasheets-2827.pdf | 18.796mm | 7.37mm | 7.4mm | 4 Weeks | Copper | Tin | No | Brazed Seam | Copper | Tin | 18-22 AWG | 22 AWG | 18 AWG | Spring, Snap | 0.740 18.80mm | Non-Insulated | Tin | 8 Stud | 0.290 7.37mm | 0.160 (4.06mm) | ||||||||||||||||||||||||||||||||||||||||
8-34166-1 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Plasti-Grip | Free Hanging | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | 600V | RoHS Compliant | 2005 | /files/teconnectivityamp-8341661-datasheets-1657.pdf | 23.37mm | 600V | Blue | Not Applicable | 15 Weeks | Unknown | ACTIVE (Last Updated: 5 days ago) | Receptacle | Female | Compliant | 4.95 mm | Straight | EAR99 | Copper | Tin | 8536.90.40.00 | Serrated Termination | 0.416 10.57mm | FORK TERMINAL | 14-16 AWG | 2.62 mm2 | 14 AWG | 16 AWG | Standard | 0.920 23.37mm | 4.9 mm | Insulated | 0.118 ~ 0.193 (3.00mm ~ 4.90mm) | Yes | 2.54μm | No | 4.34 mm | 790μm | Poly-Vinyl Chloride (PVC) | 8 Stud | M4 | 0.385 9.78mm | 790μm | 0.171 (4.34mm) | 0.312 7.92mm | ||||||||||||||||||||
8-34155-1 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Plasti-Grip | Free Hanging, Stud | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | 600V | RoHS Compliant | 2003 | /files/teconnectivityampconnectors-2341551-datasheets-7560.pdf | 23.37mm | 600V | Red | Not Applicable | 15 Weeks | Unknown | ACTIVE (Last Updated: 4 days ago) | Receptacle | Female | Compliant | 3.68 mm | Straight | EAR99 | Copper | Tin | 8536.90.40.00 | 16 AWG | Serrated Termination | 0.416 10.57mm | FORK TERMINAL | 16-22 AWG | 1.65 mm2 | 16 AWG | 22 AWG | Standard | 0.920 23.37mm | 3.556 mm | Insulated | 0.105 ~ 0.140 (2.67mm ~ 3.56mm) | Yes | 2.54μm | No | 4.34 mm | 787.4μm | Poly-Vinyl Chloride (PVC) | 8 Stud | M4 | 0.375 9.53mm | 790μm | 0.171 (4.34mm) | 0.312 7.92mm | |||||||||||||||||||
8-34128-1 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Solistrand | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 1997 | /files/teconnectivityamp-8341281-datasheets-1666.pdf | 17.4mm | Not Applicable | 17 Weeks | ACTIVE (Last Updated: 4 months ago) | yes | Compliant | 2.16 mm | EAR99 | Copper | 8536.90.40.00 | Brazed Seam, Serrated Termination | 0.181 4.60mm | WIRE TERMINAL | 14-16 AWG | 2.62 mm2 | 14 AWG | 16 AWG | Standard | 0.685 17.40mm | FEMALE | Non-Insulated | Tin | No | 4.34 mm | 790μm | 8 Stud | M4 | 0.385 9.78mm | 790μm | 0.171 (4.34mm) | 0.312 7.92mm | |||||||||||||||||||||||||||||||
MVU14-10FX | Artery |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Scotchlok™ | Free Hanging | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 2000 | /files/3m-ma250dmmfk-datasheets-3277.pdf | 100 | 22.86mm | Blue | 3 Weeks | 589.670081g | Unknown | Copper, ETP | 16 AWG | Butted Seam | 0.450 11.43mm | 14-16 AWG | 16 AWG | 14 AWG | Standard | 0.900 22.86mm | Copper | Insulated | 0.170 (4.32mm) | Tin | Vinyl | 10 Stud | 0.340 8.64mm | 0.290 7.37mm | ||||||||||||||||||||||||||||||||||||||
P18-8FF-C | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2001 | 3.56mm | 18.288mm | 7.87mm | 4 Weeks | 1.78 mm | EAR99 | Copper | 8536.90.40.00 | Brazed Seam, Serrated Termination | FORK TERMINAL | 18-22 AWG | 22 AWG | 18 AWG | Flanged | 0.720 18.29mm | FEMALE | Non-Insulated | Tin | 8 Stud | 0.310 7.87mm | 0.170 (4.32mm) | |||||||||||||||||||||||||||||||||||||||||
P18-6FN-C | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2001 | /files/panduitcorp-p186fnm-datasheets-9611.pdf | 3.56mm | 16.002mm | 6.1mm | 6.1mm | 4 Weeks | 1.78 mm | Straight | EAR99 | Copper | Tin | No | 8536.90.40.00 | 16 AWG | Brazed Seam | FORK TERMINAL | 16-22 AWG | 22 AWG | 18 AWG | Standard | 0.630 16.00mm | FEMALE | Non-Insulated | 6 Stud | 0.240 6.10mm | 0.150 (3.81mm) | ||||||||||||||||||||||||||||||||||||
PV10-8FX-D | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2011 | /files/panduitcorp-pv108fxd-datasheets-2729.pdf | 28.194mm | 9.4mm | Yellow | 4 Weeks | EAR99 | Copper | No | 8536.90.40.00 | Brazed Seam, Serrated Termination | FORK TERMINAL | 10-12 AWG | 12 AWG | 10 AWG | Standard | 1.110 28.19mm | Insulated | 0.250 (6.35mm) | Tin | Vinyl | 8 Stud | 0.370 9.40mm | 0.170 (4.32mm) | |||||||||||||||||||||||||||||||||||||||
8-34156-1 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Plasti-Grip | Free Hanging, Stud | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | 600V | RoHS Compliant | 2008 | /files/teconnectivityampconnectors-34156-datasheets-7889.pdf | 23.37mm | 600V | Red | Not Applicable | 18 Weeks | Unknown | ACTIVE (Last Updated: 4 days ago) | Receptacle | Female | Compliant | 3.68 mm | Straight | EAR99 | Copper | Tin | 8536.90.40.00 | 16 AWG | Serrated Termination | 0.416 10.57mm | FORK TERMINAL | 16-22 AWG | 16 AWG | 22 AWG | Standard | 0.920 23.37mm | 3.56 mm | Insulated | 0.105 ~ 0.140 (2.67mm ~ 3.56mm) | Yes | 2.54μm | No | 5 mm | 787.4μm | Poly-Vinyl Chloride (PVC) | 10 Stud | 0.375 9.53mm | 790μm | 0.197 (5.00mm) | 0.312 7.92mm | |||||||||||||||||||||
PV14-8FX-M | Panduit Corp | $0.33 |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2001 | https://pdf.utmel.com/r/datasheets/panduit-pv148fxm-datasheets-1638.pdf | 24.384mm | 7.9mm | Blue | 4 Weeks | 1.170268kg | EAR99 | Copper | No | 8536.90.40.00 | Brazed Seam, Serrated Termination | FORK TERMINAL | 14-16 AWG | 16 AWG | 14 AWG | Standard | 0.960 24.38mm | Insulated | 0.200 (5.08mm) | Tin | Vinyl | 8 Stud | 0.310 7.87mm | 0.170 (4.32mm) | |||||||||||||||||||||||||||||||||||||
BFV14-8Q | Artery |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Highland™ | Free Hanging | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | 1kV | ROHS3 Compliant | 1999 | /files/3m-ma250dmmfk-datasheets-3277.pdf | 21.59mm | 114.3mm | 7.62mm | Blue | Copper | 3 Weeks | 317.514659g | CSA, UL | Unknown | 760μm | Straight | Copper, ETP | Tin | 14 AWG | Butted Seam | 0.450 11.43mm | 14-16 AWG | 16 AWG | 14 AWG | Standard | 0.850 21.59mm | Copper | Insulated | 0.170 (4.32mm) | Tin | Vinyl | 8 Stud | M4 | 0.300 7.62mm | 0.250 6.35mm | ||||||||||||||||||||||||||||||
PV18-8F-MY | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2005 | /files/panduitcorp-pv186fmy-datasheets-7777.pdf | 23.622mm | Red | 8.1mm | 4 Weeks | 1.065942kg | Straight | EAR99 | Copper | Tin | No | 8536.90.40.00 | Brazed Seam, Serrated Termination | FORK TERMINAL | 18-22 AWG | 22 AWG | 18 AWG | Standard | 0.930 23.62mm | Insulated | 0.150 (3.81mm) | Vinyl | 8 Stud | 0.320 8.13mm | 0.170 (4.32mm) | |||||||||||||||||||||||||||||||||||||
8-322996-1 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Solistrand | Free Hanging | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 2011 | https://pdf.utmel.com/r/datasheets/teconnectivityampconnectors-322996-datasheets-8417.pdf | 13.46mm | Not Applicable | 15 Weeks | ACTIVE (Last Updated: 5 days ago) | yes | Compliant | 2.16 mm | EAR99 | Copper | 8536.90.40.00 | Brazed Seam, Serrated Termination | 0.181 4.60mm | WIRE TERMINAL | 14-16 AWG | 2.62 mm2 | 14 AWG | 16 AWG | Standard | 0.530 13.46mm | FEMALE | Non-Insulated | Tin | 2.54μm | No | 3.68 mm | 790μm | 6 Stud | M3.5 | 0.297 7.54mm | 0.145 (3.68mm) | 0.203 5.16mm | ||||||||||||||||||||||||||||||
1-322249-0 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Plasti-Grip | Free Hanging | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 2003 | 19.02mm | 7.52mm | 600V | Red | Not Applicable | 7.52mm | 4 Weeks | Unknown | ACTIVE (Last Updated: 3 days ago) | Compliant | Straight | EAR99 | Copper | Tin | 8536.90.40.00 | Serrated Termination | 0.416 10.57mm | FORK TERMINAL | 16-22 AWG | 1.65 mm2 | 16 AWG | 22 AWG | Flanged | 0.780 19.81mm | 3.56 mm | FEMALE | Insulated | 0.105 ~ 0.140 (2.67mm ~ 3.56mm) | Yes | No | 4.34 mm | Poly-Vinyl Chloride (PVC) | 8 Stud | M4 | 0.296 7.52mm | 790μm | 0.171 (4.34mm) | 0.203 5.16mm | ||||||||||||||||||||||||
0191640030 | Molex |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Perma-Seal | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | ROHS3 Compliant | https://pdf.utmel.com/r/datasheets/molex-0191640030-datasheets-2746.pdf | Blue | 4 Weeks | yes | EAR99 | Copper | 8536.90.40.00 | RING TERMINAL | 14-16 AWG | 1.94 mm2 | Standard | 1.420 36.07mm | Insulated with Heat Shrink | 0.235 (5.97mm) | Electro-Tin | NiAc | 10 Stud | 0.400 10.16mm | 0.198 (5.03mm) | |||||||||||||||||||||||||||||||||||||||||||||
LFV14-6Q | 3M | $10.28 |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Highland™ | Free Hanging | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | Non-RoHS Compliant | https://pdf.utmel.com/r/datasheets/3m-ma250dmmfk-datasheets-3277.pdf | 22.352mm | 114.3mm | 6.35mm | Blue | 3 Weeks | 317.514659g | Female | 760μm | Straight | Copper, ETP | Tin | -14 AWG | Butted Seam | 0.450 11.43mm | 14-16 AWG | 16 AWG | 14 AWG | Spring, Snap | 0.880 22.35mm | Insulated | 0.170 (4.32mm) | Tin | Vinyl | 6 Stud | M3.5 | 0.250 6.35mm | 0.250 6.35mm | ||||||||||||||||||||||||||||||||||
P14-10FN-C | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2003 | /files/panduitcorp-p148fm-datasheets-9582.pdf | 4.06mm | 18.034mm | 7.87mm | 7.87mm | 4 Weeks | 2.29 mm | EAR99 | Copper | Tin | No | 8536.90.40.00 | Brazed Seam, Serrated Termination | FORK TERMINAL | 14-18 AWG | 16 AWG | 14 AWG | Standard | 0.710 18.03mm | FEMALE | Non-Insulated | 10 Stud | 0.310 7.87mm | 0.200 (5.08mm) | ||||||||||||||||||||||||||||||||||||||
PNF18-6F-M | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2001 | /files/panduitcorp-pnf186fm-datasheets-2759.pdf | 20.32mm | Red | 7.54mm | 4 Weeks | 911.720664g | EAR99 | Copper | Tin | No | 8536.90.40.00 | Butted Seam, Serrated Termination | FORK TERMINAL | 18-22 AWG | 22 AWG | 18 AWG | Standard | 0.800 20.32mm | Insulated | 0.136 (3.45mm) | Polyamide (PA), Nylon | 6 Stud | 0.300 7.62mm | 0.150 (3.81mm) | ||||||||||||||||||||||||||||||||||||||
PN14-6LF-M | Panduit Corp | $0.58 |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2001 | 21.844mm | 6.35mm | Blue | 6.35mm | 4 Weeks | 1.006975kg | EAR99 | Copper | Tin | No | 8536.90.40.00 | Serrated Termination | FORK TERMINAL | 14-16 AWG | 16 AWG | 14 AWG | Spring, Snap | 0.860 21.84mm | Insulated | 0.162 (4.11mm) | Polyamide (PA), Nylon | 6 Stud | 0.250 6.35mm | 0.140 (3.56mm) | |||||||||||||||||||||||||||||||||||||
8-320857-1 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Solistrand | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 1997 | /files/teconnectivityampconnectors-320857-datasheets-9198.pdf | 13.06mm | Not Applicable | 15 Weeks | ACTIVE (Last Updated: 1 week ago) | yes | Compliant | 2.16 mm | EAR99 | Copper | 8536.90.40.00 | Brazed Seam, Serrated Termination | 0.181 4.60mm | FORK TERMINAL | 14-16 AWG | 2.62 mm2 | 14 AWG | 16 AWG | Flanged | 0.545 13.84mm | Non-Insulated | Tin | No | 4.82 mm | 840μm | 10 Stud | 0.294 7.47mm | 840μm | 0.197 (5.00mm) | 0.203 5.16mm | |||||||||||||||||||||||||||||||||
8-32995-1 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Solistrand | Stud | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 1997 | /files/teconnectivityampconnectors-8329951-datasheets-2716.pdf | 19.61mm | Yellow | Not Applicable | 15 Weeks | ACTIVE (Last Updated: 1 week ago) | yes | Compliant | 3.28 mm | EAR99 | Copper | 8536.90.40.00 | Brazed Seam, Serrated Termination | 0.268 6.81mm | FORK TERMINAL | 10-12 AWG | 6.64 mm2 | 10 AWG | 12 AWG | Standard | 0.772 19.61mm | Non-Insulated | Tin | No | 4.34 mm | 990.6μm | 8 Stud | M4 | 0.406 10.31mm | 990μm | 0.171 (4.34mm) | 0.296 7.52mm | ||||||||||||||||||||||||||||||
P10-6LF-D | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2001 | /files/panduitcorp-p1010lfd-datasheets-2655.pdf | 559mm | 19.558mm | 7.62mm | Copper | 7.62mm | 4 Weeks | 725.747792g | 330 mm | Copper | Tin | No | Brazed Seam, Serrated Termination | Copper | Tin | 10-12 AWG | 12 AWG | 10 AWG | Spring, Snap | 0.770 19.56mm | Non-Insulated | Tin | 6 Stud | 0.300 7.62mm | 0.140 (3.56mm) | |||||||||||||||||||||||||||||||||||||
94776 | 3M |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Highland™ | Free Hanging | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 2002 | https://pdf.utmel.com/r/datasheets/3m-94782-datasheets-4890.pdf | 100 | 23.114mm | 8.64mm | Blue | Lead Free | 3 Weeks | 1.247379kg | Straight | Copper, ETP | 8 AWG | Butted Seam | Nylon | 0.460 11.68mm | 14-16 AWG | 16 AWG | 14 AWG | Standard | 0.910 23.11mm | Insulated | 0.170 (4.32mm) | Tin | Polyamide (PA), Nylon | 8 Stud | 0.340 8.64mm | 0.290 7.37mm | ||||||||||||||||||||||||||||||||||||
94879 | Artery |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Highland™ | Free Hanging | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 2002 | /files/3m-94865-datasheets-7744.pdf | 31.496mm | 10.9mm | Yellow | Contains Lead | 3 Weeks | 1.133981kg | Unknown | Straight | Copper, ETP | Tin | 10 AWG | Butted Seam | 0.550 13.97mm | 10-12 AWG | 10 AWG | 12 AWG | Spring, Snap | 1.240 31.50mm | Insulated | 0.250 (6.35mm) | Tin | Vinyl | 1/4 Stud | 0.430 10.92mm | 0.440 11.18mm |
Please send RFQ , we will respond immediately.