Compare | Image | Name | Manufacturer | Pricing(USD) | Quantity | Weight(Kg) | Size(LxWxH) | Part Status | Series | Mount | Mounting Type | Packaging | Moisture Sensitivity Level (MSL) | Termination | Max Operating Temperature | Min Operating Temperature | Voltage - Rated | RoHS Status | Published | Datasheet | Voltage - Rated DC | Diameter | Length | Width | Voltage - Rated AC | Color | Lead Free | Material | Depth | Factory Lead Time | Weight | Approval Agency | REACH SVHC | Lifecycle Status | Pbfree Code | Connector Type | Gender | ELV | Sealable | Diameter - Inside | Orientation | ECCN Code | Contact Material | Contact Plating | Total Number of Contacts | Radiation Hardening | Lead Length | Body/Shell Style | HTS Code | Wire/Cable Gauge | Feature | Subcategory | Cable Length | Body Material | Body Breadth | Length - Termination | Terminal and Terminal Block Type | Body Plating | Number of Rows | Wire Gauge | Wire Cross Section | Wire Gauge (Max) | Wire Gauge (Min) | Terminal Type | Length - Overall | Sensing Distance | Wire/Cable Diameter | Terminal Gender | Insulation | Insulation Diameter | Tab Thickness | Plating | Insulated Wire Support | Contact Finish | Reliability | Body Depth | Mating Contact Pitch | Contact Pattern | Plating Thickness | Width - Tab | Heavy Duty | Underplate Material | Contact Design | Wire Size (Min) | Stud Diameter | Material Thickness | Material - Insulation | Government Qualified | Stud/Tab Size | Number of Holes | Stud Size | Width - Outer Edges | Tongue Thickness | Tongue Inside Opening | Length - Ring Center to Termination |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
325150 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | PIDG | Free Hanging | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 2008 | /files/teconnectivityampconnectors-83251502-datasheets-3425.pdf | 26.82mm | 7.52mm | 300V | Yellow | Lead Free | 17 Weeks | Unknown | ACTIVE (Last Updated: 4 days ago) | yes | Female | Compliant | Straight | EAR99 | Copper | Tin | 8536.90.40.00 | Serrated Termination | 0.591 15.01mm | WIRE TERMINAL | 10-12 AWG | 12 AWG | 10 AWG | Flanged | 1.056 26.82mm | 6.35 mm | Insulated | 0.150 ~ 0.250 (3.81mm ~ 6.35mm) | Yes | No | 3.68 mm | Polyamide (PA), Nylon | 6 Stud | M3.5 | 0.296 7.52mm | 1.0668mm | 0.145 (3.68mm) | 0.250 6.35mm | ||||||||||||||||||||||||||||||||||||||||||||
MNG10-8FFBK | Artery |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Scotchlok™ | Free Hanging | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 2013 | 26.162mm | Yellow | 8.12mm | 3 Weeks | 1.054602kg | Copper, ETP | Tin | Copper | 0.550 13.97mm | 10-12 AWG | 12 AWG | 10 AWG | Flanged | 1.030 26.16mm | Insulated | 0.250 (6.35mm) | Polyamide (PA), Nylon | 8 Stud | 0.320 8.13mm | 0.290 7.37mm | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
MNG10-10FLK | Artery |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Scotchlok™ | Free Hanging | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 2002 | /files/3m-mng1010flk-datasheets-7094.pdf | 26.162mm | Yellow | 8.12mm | 3 Weeks | 1.020583kg | Copper, ETP | 0.550 13.97mm | 10-12 AWG | 12 AWG | 10 AWG | Spring, Snap | 1.030 26.16mm | Insulated | 0.250 (6.35mm) | Tin | Polyamide (PA), Nylon | 10 Stud | 0.320 8.13mm | 0.280 7.11mm | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
MH18-10FLK | Artery |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Scotchlok™ | Free Hanging | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | 600V | RoHS Compliant | 2002 | /files/3m-mh186flk-datasheets-3186.pdf | 600V | 25.4mm | Red | 8.12mm | 3 Weeks | 226.796213g | Male | Copper, ETP | Tin | Brazed Seam | Copper | 0.610 15.49mm | 18-22 AWG | 18 AWG | 22 AWG | Spring, Snap | 1.000 25.40mm | Insulated with Heat Shrink | Polyolefin | 10 Stud | 0.320 8.13mm | 0.150 3.81mm | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
533141-000 | TE Connectivity Raychem Cable Protection |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Dura-Seal | Free Hanging | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | 125°C | -55°C | 2006 | https://pdf.utmel.com/r/datasheets/teconnectivityaerospacedefenseandmarine-486501000-datasheets-6823.pdf | 34.9758mm | Blue | Copper | 9.91mm | 10 Weeks | ACTIVE (Last Updated: 5 days ago) | Yes | Copper | Tin | Copper | Tin | 14-16 AWG | 16 AWG | 14 AWG | Standard | 1.378 35.00mm | Insulated with Heat Shrink | 0.181 (4.60mm) | Tin | Yes | Tin | No | Copper | 4.3 mm | Polyamide (PA), Nylon | No | 1 | 0.394 10.00mm | 787.4μm | 0.207 (5.26mm) | ||||||||||||||||||||||||||||||||||||||||||||||||||
2-326741-1 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Plasti-Grip | Free Hanging | Free Hanging (In-Line) | Tape & Reel (TR) | 1 (Unlimited) | Crimp | RoHS Compliant | 2008 | /files/teconnectivityampconnectors-23267411-datasheets-7072.pdf | 19.43mm | 600V | Blue | Lead Free | 12 Weeks | ACTIVE (Last Updated: 1 week ago) | Compliant | EAR99 | Copper | 8536.90.40.00 | Serrated Termination | 0.416 10.57mm | FORK TERMINAL | Tin | 14-16 AWG | 2.62 mm2 | 14 AWG | 16 AWG | Standard | 0.765 19.43mm | 4.9 mm | FEMALE | Insulated | 0.118 ~ 0.193 (3.00mm ~ 4.90mm) | Yes | No | 4.34 mm | Poly-Vinyl Chloride (PVC) | 8 Stud | M4 | 0.297 7.54mm | 790μm | 0.171 (4.34mm) | 0.203 5.16mm | |||||||||||||||||||||||||||||||||||||||||||||||
MNG10-8FLK | Artery |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Scotchlok™ | Free Hanging | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | 600V | RoHS Compliant | 2000 | /files/3m-mng108flk-datasheets-4313.pdf | 26.162mm | Yellow | Copper | 8.12mm | 3 Weeks | 816.466266g | CSA, UL | Straight | Copper, ETP | Tin | 3m | 10 AWG | 3m | 0.550 13.97mm | 10-12 AWG | 10 AWG | 12 AWG | Spring, Snap | 1.030 26.16mm | 3 m | Insulated | 0.250 (6.35mm) | 1.016mm | Tin | 8.128mm | Polyamide (PA), Nylon | 8 Stud | 0.320 8.13mm | 0.280 7.11mm | |||||||||||||||||||||||||||||||||||||||||||||||||||
PN10-14LF-D | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2003 | 29.718mm | 11.7mm | Yellow | 11.68mm | 4 Weeks | EAR99 | Copper | Tin | No | 8536.90.40.00 | Butted Seam, Serrated Termination | FORK TERMINAL | 10-12 AWG | 12 AWG | 10 AWG | Spring, Snap | 1.170 29.72mm | Insulated | 0.225 (5.72mm) | Polyamide (PA), Nylon | 1/4 Stud | 0.460 11.68mm | 0.250 (6.35mm) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
52403 | TE Connectivity AMP Connectors | $1.81 |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | PIDG | Free Hanging | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 2008 | https://pdf.utmel.com/r/datasheets/teconnectivityampconnectors-52403-datasheets-7074.pdf | 21.5138mm | 300V | Yellow | Lead Free | Bronze | 31 Weeks | ACTIVE (Last Updated: 3 days ago) | TELECOM AND DATACOM CONNECTOR | Female | 2.1336 mm | Phosphor Bronze | 50 | PLUG | Serrated Termination | D Type Connectors | 0.6 inch | 0.331 8.41mm | 2 | 22-26 AWG | 26 AWG | 22 AWG | Spring, Snap | 0.847 21.51mm | Insulated | 0.050 ~ 0.082 (1.27mm ~ 2.08mm) | Yes | Tin | COMMERCIAL | 0.389 inch | 0.085 inch | RECTANGULAR | 30μin | No | PREASSEM CONN | 28 AWG | 3.5052 mm | Polyamide (PA), Nylon | 6 Stud | M3.5 | 0.250 6.35mm | 500μm | 0.144 (3.66mm) | 0.235 5.97mm | |||||||||||||||||||||||||||||||||||||
MV10-10FBK | Artery |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Scotchlok™ | Free Hanging | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 2002 | 26.162mm | Yellow | 8.12mm | 3 Weeks | Copper, ETP | Brazed Seam | Copper | 0.550 13.97mm | 10-12 AWG | 12 AWG | 10 AWG | Standard | 1.030 26.16mm | Insulated | 0.250 (6.35mm) | Tin | Vinyl | 10 Stud | 0.320 8.13mm | 0.290 7.37mm | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1-1377173-5 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Plasti-Grip | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 2013 | /files/teconnectivityampconnectors-13771734-datasheets-9158.pdf | 21.79mm | Red | Copper | 13 Weeks | ACTIVE (Last Updated: 3 days ago) | Compliant | No | Copper | Serrated Termination | 0.416 10.57mm | 16-22 AWG | Standard | 0.858 21.79mm | Insulated | 0.105 ~ 0.140 (2.67mm ~ 3.56mm) | Tin | Yes | Tin | No | 3.68 mm | Poly-Vinyl Chloride (PVC) | No | 6 Stud | M3.5 | 0.250 6.35mm | 790μm | 0.145 (3.68mm) | 0.312 7.92mm | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
MNG14-6FBK | 3M | $0.90 |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Scotchlok™ | Free Hanging | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 2015 | 21.844mm | Blue | 3 Weeks | 1.222431kg | Copper, ETP | 0.460 11.68mm | 14-16 AWG | 16 AWG | 14 AWG | Standard | 0.860 21.84mm | Insulated | 0.170 (4.32mm) | Tin | Polyamide (PA), Nylon | 6 Stud | 0.300 7.62mm | 0.250 6.35mm | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
PMV2-5FB-C | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2001 | 23.368mm | 8.382mm | Blue | 8.64mm | 4 Weeks | 113.398093g | EAR99 | Copper | Tin | No | 8536.90.40.00 | Butted Seam, Serrated Termination | FORK TERMINAL | 14-16 AWG | 2.5 mm2 | 16 AWG | 14 AWG | Standard | 0.920 23.37mm | FEMALE | Insulated | 0.185 (4.70mm) | Vinyl | M5 Stud | 0.340 8.64mm | 0.210 (5.33mm) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
MNG18-10FFBK | 3M |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Scotchlok™ | Free Hanging | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 2000 | 21.336mm | Red | 3 Weeks | 1.031923kg | Copper, ETP | 0.440 11.18mm | 18-22 AWG | 22 AWG | 18 AWG | Flanged | 0.840 21.34mm | Insulated | 0.145 (3.68mm) | Tin | Polyamide (PA), Nylon | 10 Stud | 0.300 7.62mm | 0.250 6.35mm | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
P18-10LFN-C | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2004 | https://pdf.utmel.com/r/datasheets/panduitcorp-p188lfc-datasheets-2827.pdf | 18.796mm | 7.11mm | 7.1mm | 4 Weeks | EAR99 | Copper | Tin | No | 8536.90.40.00 | Brazed Seam | FORK TERMINAL | 18-22 AWG | 22 AWG | 18 AWG | Spring, Snap | 0.740 18.80mm | FEMALE | Non-Insulated | 10 Stud | 0.280 7.11mm | 0.190 (4.83mm) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
PN14-14F-3K | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Reel | Not Applicable | Crimp | ROHS3 Compliant | 2001 | /files/panduitcorp-pn146f3k-datasheets-1709.pdf | 26.162mm | Blue | 4 Weeks | EAR99 | Copper | No | 8536.90.40.00 | Serrated Termination | FORK TERMINAL | 14-16 AWG | 2.5 mm2 | 16 AWG | 14 AWG | Standard | 1.030 26.16mm | FEMALE | Insulated | 0.160 (4.06mm) | Tin | Polyamide (PA), Nylon | 1/4 Stud | 0.440 11.18mm | 0.270 (6.86mm) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
30-4-WN | Artery |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Free Hanging | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | Yellow | 3 Weeks | 3.129787g | Brazed Seam | 24-26 AWG | 26 AWG | 24 AWG | Standard | Insulated | Polyamide (PA), Nylon | 4 Stud | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
2-1377173-8 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Plasti-Grip | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 2013 | https://pdf.utmel.com/r/datasheets/teconnectivityampconnectors-13771734-datasheets-9158.pdf | 20.447mm | Blue | Copper | 19 Weeks | ACTIVE (Last Updated: 5 days ago) | Compliant | No | Copper | Serrated Termination | 0.384 9.75mm | 14-16 AWG | Standard | 0.788 20.02mm | Insulated | 0.120 ~ 0.195 (3.05mm ~ 4.95mm) | Tin | No | Tin | No | 4.17 mm | Poly-Vinyl Chloride (PVC) | No | 8 Stud | M4 | 0.250 6.35mm | 812.8μm | 0.171 (4.34mm) | 0.280 7.11mm | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
2-1377173-9 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Plasti-Grip | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 2013 | https://pdf.utmel.com/r/datasheets/teconnectivityampconnectors-13771734-datasheets-9158.pdf | 19.43mm | Blue | Copper | 19 Weeks | ACTIVE (Last Updated: 1 week ago) | Compliant | No | Copper | Serrated Termination | 0.416 10.57mm | 14-16 AWG | Standard | 0.765 19.43mm | Insulated | 0.118 ~ 0.193 (3.00mm ~ 4.90mm) | Tin | Yes | No | 4.17 mm | Poly-Vinyl Chloride (PVC) | No | 8 Stud | M4 | 0.297 7.54mm | 840μm | 0.171 (4.34mm) | 0.203 5.16mm | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
8230 | Keystone Electronics |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Free Hanging | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | Non-RoHS Compliant | /files/keystoneelectronics-1345-datasheets-1258.pdf | 17.78mm | 7.62mm | Blue | Contains Lead | Copper | 6 Weeks | 4.45 mm | EAR99 | Copper, ETP | 8536.90.40.00 | 0.450 11.43mm | WIRE TERMINAL | 14-16 AWG | 14 AWG | 16 AWG | Standard | 0.700 17.78mm | Insulated | 0.175 (4.45mm) | Tin | Vinyl | 6 Stud | 0.300 7.62mm | 0.250 6.35mm | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
4-1377173-0 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Plasti-Grip | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 2013 | /files/teconnectivityampconnectors-13771734-datasheets-9158.pdf | 26.899mm | Yellow | Copper | 19 Weeks | ACTIVE (Last Updated: 4 months ago) | Compliant | No | Copper | Serrated Termination | 0.591 15.01mm | 10-12 AWG | Flanged | 1.017 25.83mm | Insulated | 0.150 ~ 0.250 (3.81mm ~ 6.35mm) | Tin | Yes | Tin | No | 4.82 mm | Poly-Vinyl Chloride (PVC) | No | 10 Stud | 0.416 10.57mm | 1.0668mm | 0.197 (5.00mm) | 0.250 6.35mm | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
8233 | Keystone Electronics |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Free Hanging | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | Non-RoHS Compliant | /files/keystoneelectronics-1345-datasheets-1258.pdf | 21.336mm | 8.13mm | Yellow | Lead Free | Copper | 6 Weeks | 6.48 mm | EAR99 | Copper, ETP | 8536.90.40.00 | 0.550 13.97mm | FORK TERMINAL | 10-12 AWG | 12 AWG | 10 AWG | Standard | 0.840 21.34mm | Insulated | 0.255 (6.48mm) | Tin | Vinyl | 6 Stud | 0.320 8.13mm | 0.290 7.37mm | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
130620 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | PIDG | Free Hanging | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 2006 | 33mm | 13.5mm | 300V | Yellow | Not Applicable | 13.5mm | 13 Weeks | ACTIVE (Last Updated: 4 days ago) | yes | Compliant | 6.4 mm | EAR99 | Copper | Tin | 8536.90.40.00 | Serrated Termination | 0.606 15.39mm | FORK TERMINAL | 10-12 AWG | 12 AWG | 10 AWG | Standard | 1.299 33.00mm | 6.4 mm | Insulated | 0.150 ~ 0.252 (3.81mm ~ 6.40mm) | Yes | 2.54μm | No | 5 mm | 990.6μm | Polyamide (PA), Nylon | M5 Stud | M5 | 0.531 13.49mm | 1mm | 0.197 (5.00mm) | 0.437 11.10mm | ||||||||||||||||||||||||||||||||||||||||||||
P14-6LFW-C | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2001 | /files/panduitcorp-p146lfm-datasheets-2543.pdf | 4.06mm | 17.78mm | 7.37mm | Copper | 7.37mm | 4 Weeks | 2.29 mm | Copper | Tin | No | Brazed Seam, Serrated Termination | Copper | Tin | 14-16 AWG | 16 AWG | 14 AWG | Spring, Snap | 0.700 17.78mm | Non-Insulated | Tin | 6 Stud | 0.290 7.37mm | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
PNF10-10LF-2K | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Reel | Not Applicable | Crimp | ROHS3 Compliant | 2001 | 26.67mm | Yellow | 8.64mm | 4 Weeks | EAR99 | Copper | Tin | No | 8536.90.40.00 | Serrated Termination | FORK TERMINAL | 10-12 AWG | 6 mm2 | 12 AWG | 10 AWG | Spring, Snap | 1.050 26.67mm | Insulated | 0.135 ~ 0.225 (3.43mm ~ 5.72mm) | Polyamide (PA), Nylon | 10 Stud | 0.340 8.64mm | 0.190 (4.83mm) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
9-1377173-7 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | PIDG | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 2013 | /files/teconnectivityampconnectors-13771734-datasheets-9158.pdf | Blue | Copper | 16 Weeks | ACTIVE (Last Updated: 1 week ago) | Compliant | Copper | Serrated Termination | 0.404 10.26mm | 14-16 AWG | Standard | 0.908 23.06mm | Insulated | 0.115 ~ 0.170 (2.92mm ~ 4.32mm) | Tin | Yes | Tin | No | 4.17 mm | Polyamide (PA), Nylon | No | 8 Stud | M4 | 0.375 9.53mm | 840μm | 0.171 (4.34mm) | 0.312 7.92mm | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
3-1377173-2 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Plasti-Grip | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 2013 | https://pdf.utmel.com/r/datasheets/teconnectivityampconnectors-13771734-datasheets-9158.pdf | 27.99mm | Blue | Copper | 28 Weeks | ACTIVE (Last Updated: 4 days ago) | Compliant | No | Copper | Serrated Termination | 0.386 9.80mm | 14-16 AWG | Standard | 1.059 26.90mm | Insulated | 0.118 ~ 0.193 (3.00mm ~ 4.90mm) | Tin | No | Tin | No | 6.35 mm | Poly-Vinyl Chloride (PVC) | No | 1/4 Stud | M6 | 0.472 12.00mm | 812.8μm | 0.250 (6.35mm) | 0.437 11.10mm | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
3-1377173-4 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Plasti-Grip | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 2013 | https://pdf.utmel.com/r/datasheets/teconnectivityampconnectors-13771734-datasheets-9158.pdf | 19.863mm | Blue | Copper | 21 Weeks | ACTIVE (Last Updated: 4 days ago) | Compliant | No | Copper | Serrated Termination | 0.426 10.82mm | 14-16 AWG | Flanged | 0.780 19.81mm | Insulated | 0.195 (4.95mm) | Tin | No | Tin | No | 4.17 mm | No | 8 Stud | M4 | 0.294 7.47mm | 812.8μm | 0.171 (4.34mm) | 0.193 4.90mm | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
1279 | Keystone Electronics | $0.56 |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Free Hanging | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | ROHS3 Compliant | https://pdf.utmel.com/r/datasheets/keystoneelectronics-1279-datasheets-7011.pdf | 19.05mm | Lead Free | 6 Weeks | EAR99 | Brass | 8536.90.40.00 | 0.330 8.38mm | WIRE TERMINAL | Standard | 0.750 19.05mm | Non-Insulated | Tin | 8 Stud | 0.300 7.62mm | 0.171 (4.34mm) | 0.250 6.35mm | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
0191640849 | Molex |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Perma-Seal | Free Hanging (In-Line) | Tape & Reel (TR) | 1 (Unlimited) | Crimp | ROHS3 Compliant | Blue | 30 Weeks | RING TERMINAL | 14-16 AWG | Flanged | Insulated with Heat Shrink | 0.235 (5.97mm) | NiAc | 10 Stud |
Please send RFQ , we will respond immediately.