| Compare | Image | Name | Manufacturer | Pricing(USD) | Quantity | Weight(Kg) | Size(LxWxH) | Part Status | Series | Mount | Mounting Type | Packaging | Moisture Sensitivity Level (MSL) | Termination | RoHS Status | Published | Datasheet | Diameter | Length | Height | Width | Voltage - Rated AC | Color | Lead Free | Material | Depth | Factory Lead Time | Weight | Approval Agency | REACH SVHC | Lifecycle Status | Pbfree Code | Gender | ELV | Thickness | Diameter - Inside | Orientation | ECCN Code | Contact Material | Contact Plating | Radiation Hardening | HTS Code | Wire/Cable Gauge | Feature | Body Material | Terminal and Terminal Block Type | Body Plating | Wire Gauge | Wire Cross Section | Wire Gauge (Max) | Wire Gauge (Min) | Terminal Type | Length - Overall | Wire/Cable Diameter | Terminal Gender | Insulation | Insulation Diameter | Insulated Wire Support | Contact Finish | Plating Thickness | Heavy Duty | Stud Diameter | Material Thickness | Material - Insulation | Stud/Tab Size | Number of Holes | Stud Size | Width - Outer Edges | Tongue Thickness |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| PM6-5R-L | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2006 | /files/panduitcorp-p108rl-datasheets-6875.pdf | 20.574mm | Copper | 4 Weeks | 81.646627g | Female | 0.040 1.02mm | Copper | Tin | No | Brazed Seam, Serrated Termination | 10-12 AWG | 12 AWG | 10 AWG | Circular | 0.810 20.57mm | Non-Insulated | Tin | M5 Stud | 0.374 9.50mm | ||||||||||||||||||||||||||||||||||||
| 34112-3 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Solistrand | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 2009 | /files/teconnectivityampconnectors-2341122-datasheets-0263.pdf | 15.7734mm | Not Applicable | Nickel | 4 Weeks | ACTIVE (Last Updated: 3 days ago) | yes | Compliant | 0.031 0.79mm | 1.55 mm | EAR99 | Copper | Unplated | 8536.90.40.00 | Brazed Seam, Serrated Termination | RING TERMINAL | 16-22 AWG | Circular | 0.621 15.77mm | Non-Insulated | No | 5 mm | 790μm | 10 Stud | 1 | 0.312 7.92mm | 790μm | ||||||||||||||||||||||||||||||
| 322204 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Solistrand | Free Hanging | Free Hanging (In-Line), Right Angle | Bulk | 1 (Unlimited) | Crimp, Flag | RoHS Compliant | 1997 | /files/teconnectivityampconnectors-322204-datasheets-0643.pdf | 30.48mm | Blue | Lead Free | 15.88mm | 4 Weeks | ACTIVE (Last Updated: 4 days ago) | yes | Female | 0.045 1.14mm | 5.69 mm | Right Angle | EAR99 | Copper | 8536.90.40.00 | 6 AWG | Brazed Seam, Serrated Termination | RING TERMINAL | 6 AWG | Circular | 1.200 30.48mm | Non-Insulated | Tin | 2.54μm | No | 8.3312 mm | 1.2192mm | 3/8 Stud | 1 | 0.625 15.88mm | 1.22mm | |||||||||||||||||||||||||
| PMV2-3RB-C | Panduit Corp | $0.81 |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2006 | 20.574mm | 5.588mm | Blue | 4 Weeks | 99.790321g | 0.032 0.81mm | EAR99 | Copper | No | 8536.90.40.00 | Butted Seam, Serrated Termination | RING TERMINAL | 14-16 AWG | 2.5 mm2 | 16 AWG | 14 AWG | Circular | 0.810 20.57mm | FEMALE | Insulated | 0.185 (4.70mm) | Tin | Vinyl | M3 Stud | 0.230 5.84mm | ||||||||||||||||||||||||||||||
| 10-6-WN | 3M |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Free Hanging | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | ROHS3 Compliant | 1998 | /files/3m-108wn-datasheets-9739.pdf | Yellow | 3 Weeks | 270.000858mg | Brazed Seam | 22-26 AWG | 26 AWG | 24 AWG | Circular | Insulated | Polyamide (PA), Nylon | 6 Stud | |||||||||||||||||||||||||||||||||||||||||||||
| 8-326875-1 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | PIDG | Free Hanging | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 2011 | /files/teconnectivityampconnectors-23268751-datasheets-0950.pdf | 18.796mm | 300V | Yellow | Not Applicable | 14 Weeks | ACTIVE (Last Updated: 1 week ago) | yes | Compliant | 0.018 0.46mm | Straight | EAR99 | Copper | 8536.90.40.00 | Serrated Termination | WIRE TERMINAL | 22-26 AWG | 22 AWG | 26 AWG | Circular | 0.740 18.80mm | 2.08 mm | FEMALE | Insulated | 0.050 ~ 0.082 (1.27mm ~ 2.08mm) | Yes | Tin | No | 3.68 mm | Polyamide (PA), Nylon | 6 Stud | 1 | M3.5 | 0.250 6.35mm | 500μm | |||||||||||||||||||||
| 8-320560-1 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | PIDG | Free Hanging | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 2009 | 21.8186mm | 300V | Blue | Lead Free | 8.71mm | 7 Weeks | Unknown | ACTIVE (Last Updated: 5 days ago) | yes | Compliant | 0.031 0.79mm | Straight | EAR99 | Copper | Tin | 8536.90.40.00 | Serrated Termination | RING TERMINAL | 14-16 AWG | 2.62 mm2 | 16 AWG | 14 AWG | Circular | 0.859 21.82mm | 3.81 mm | Insulated | 0.105 ~ 0.150 (2.67mm ~ 3.81mm) | Yes | No | 4.17 mm | Polyamide (PA), Nylon | 8 Stud | 1 | M4 | 0.343 8.71mm | 840μm | ||||||||||||||||||||
| 8-32947-1 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Plasti-Grip | Free Hanging | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 2004 | /files/teconnectivityamp-8329471-datasheets-2412.pdf | 20.55mm | 600V | Red | Not Applicable | 7 Weeks | ACTIVE (Last Updated: 3 days ago) | Compliant | 0.031 0.79mm | EAR99 | Copper | 8536.90.40.00 | Serrated Termination | RING TERMINAL | 16-22 AWG | 16 AWG | 22 AWG | Circular | 0.809 20.55mm | 3.18 mm | FEMALE | Insulated | 0.080 ~ 0.125 (2.03mm ~ 3.18mm) | Yes | Tin | No | 3.68 mm | 790μm | Poly-Vinyl Chloride (PVC) | 6 Stud | 1 | M3.5 | 0.281 7.14mm | 790μm | ||||||||||||||||||||||
| PMV1-5RB-CY | Panduit Corp | $0.80 |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2006 | 23.114mm | Red | 8.89mm | 4 Weeks | 108.862169g | 0.032 0.81mm | EAR99 | Copper | Tin | No | 8536.90.40.00 | Butted Seam, Serrated Termination | RING TERMINAL | 18-22 AWG | 1.5 mm2 | 22 AWG | 18 AWG | Circular | 0.910 23.11mm | Insulated | 0.160 (4.06mm) | Vinyl | M5 Stud | 0.350 8.89mm | |||||||||||||||||||||||||||||||
| 8-323912-1 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | PIDG | Free Hanging | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 2010 | /files/teconnectivityampconnectors-23239121-datasheets-8558.pdf | 13.33mm | 300V | Yellow | Not Applicable | 15 Weeks | No SVHC | ACTIVE (Last Updated: 4 months ago) | yes | Compliant | 0.018 0.46mm | Straight | EAR99 | Copper | 8536.90.40.00 | 22 AWG | Serrated Termination | WIRE TERMINAL | 22-26 AWG | 22 AWG | 26 AWG | Circular | 0.525 13.34mm | 2.08 mm | FEMALE | Insulated | 0.050 ~ 0.082 (1.27mm ~ 2.08mm) | Yes | Tin | No | 2.36 mm | Polyamide (PA), Nylon | 2 Stud | 1 | M2 | 0.140 3.56mm | 500μm | |||||||||||||||||||
| PN22-6R-M | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2013 | /files/panduitcorp-pn226rm-datasheets-0607.pdf | 17.53mm | 5.08mm | Yellow | 5.08mm | 4 Weeks | 331.122458g | 0.020 0.51mm | EAR99 | Copper | Tin | No | 8536.90.40.00 | RING TERMINAL | 22-26 AWG | 22 AWG | 26 AWG | Circular | 0.690 17.53mm | Insulated | 0.090 (2.29mm) | Polyamide (PA), Nylon | 6 Stud | 0.200 5.08mm | ||||||||||||||||||||||||||||||||
| 8-36150-1 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | PIDG | Free Hanging | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 2001 | /files/teconnectivityampconnectors-36150-datasheets-2034.pdf | 17.07mm | 300V | Red | Not Applicable | 5.54mm | 16 Weeks | Unknown | ACTIVE (Last Updated: 1 day ago) | yes | Female | Compliant | 0.031 0.79mm | Straight | EAR99 | Copper | Tin | 8536.90.40.00 | 16 AWG | Serrated Termination | RING TERMINAL | 16-22 AWG | 22 AWG | 16 AWG | Circular | 0.672 17.07mm | 3.56 mm | Insulated | 0.105 ~ 0.140 (2.67mm ~ 3.56mm) | Yes | 2.54μm | No | 3.68 mm | 840μm | Polyamide (PA), Nylon | 6 Stud | 1 | M3.5 | 0.218 5.54mm | 840μm | ||||||||||||||||
| 8-32960-1 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Plasti-Grip | Free Hanging | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 2005 | /files/teconnectivityampconnectors-32960-datasheets-8016.pdf | 22.12mm | 600V | Blue | Not Applicable | 7 Weeks | No SVHC | ACTIVE (Last Updated: 1 week ago) | Compliant | 0.031 0.79mm | EAR99 | Copper | 8536.90.40.00 | Serrated Termination | RING TERMINAL | 14-16 AWG | 2.62 mm2 | 14 AWG | 16 AWG | Circular | 0.871 22.12mm | 3.683 mm | FEMALE | Insulated | 0.105 ~ 0.145 (2.67mm ~ 3.68mm) | Yes | Tin | No | 4.82 mm | 790μm | Poly-Vinyl Chloride (PVC) | 10 Stud | 1 | 0.343 8.71mm | 840μm | |||||||||||||||||||||
| 0190670018 | Molex |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | NylaKrimp | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | ROHS3 Compliant | /files/molex-0190670022-datasheets-2838.pdf | Red | 4 Weeks | yes | 0.045 1.14mm | EAR99 | Copper | 8536.90.40.00 | Brazed Seam | RING TERMINAL | 8 AWG | 10.5 mm2 | Circular | 1.510 38.35mm | Insulated | 0.350 (8.89mm) | Electro-Tin | Polyamide (PA), Nylon | 1/4 Stud | 0.588 14.94mm | ||||||||||||||||||||||||||||||||||||||
| P14-6RHT6-C | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2001 | /files/panduitcorp-p1410rht6m-datasheets-8465.pdf | 4.06mm | 15.748mm | 6.35mm | 6.35mm | 4 Weeks | 0.030 0.76mm | 2.29 mm | Straight | EAR99 | Copper | Nickel | No | 8536.90.40.00 | Brazed Seam, Serrated Termination | RING TERMINAL | 14-18 AWG | 16 AWG | 14 AWG | Circular | 0.620 15.75mm | FEMALE | Non-Insulated | 6 Stud | 0.250 6.35mm | |||||||||||||||||||||||||||||||
| MV18-8R/LK | 3M |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Scotchlok™ | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 2008 | Red | 3 Weeks | 0.030 0.76mm | Copper, ETP | Brazed Seam | 18-22 AWG | Circular | 0.930 23.62mm | Insulated | 0.145 (3.68mm) | Tin | Vinyl | 8 Stud | 0.310 7.87mm | |||||||||||||||||||||||||||||||||||||||||||
| 8-34567-1 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Solistrand | Free Hanging | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 1997 | 18.288mm | Not Applicable | 4 Weeks | ACTIVE (Last Updated: 3 days ago) | yes | Compliant | 0.048 1.22mm | 2.67 mm | EAR99 | Copper | 8536.90.40.00 | Brazed Seam, Heavy Duty, Serrated Termination | RING TERMINAL | 14-16 AWG | 2.62 mm2 | 16 AWG | 14 AWG | Circular | 0.723 18.36mm | FEMALE | Non-Insulated | No | Tin | 2.54μm | Yes | 4.82 mm | 1.27mm | 10 Stud | 1 | 0.343 8.71mm | 1.22mm | |||||||||||||||||||||||||
| 34124-1 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Solistrand | Free Hanging | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 2009 | /files/teconnectivityampconnectors-34124-datasheets-0980.pdf | 21.72mm | Not Applicable | 13 Weeks | ACTIVE (Last Updated: 3 days ago) | yes | Compliant | 0.031 0.79mm | 2.16 mm | EAR99 | Copper | Unplated | 8536.90.40.00 | Brazed Seam, Serrated Termination | RING TERMINAL | 14-16 AWG | 2.62 mm2 | 14 AWG | 16 AWG | Circular | 0.855 21.72mm | FEMALE | Non-Insulated | No | 6.35 mm | 840μm | 1/4 Stud | 1 | M6 | 0.469 11.91mm | 840μm | |||||||||||||||||||||||||
| A6-10R-C | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | /files/panduitcorp-a414rc-datasheets-3588.pdf | Silver | 4 Weeks | 0.070 1.78mm | Copper | 6 AWG | Circular Tubular (Battery Lugs) | 1.470 37.34mm | Non-Insulated | Electro-Tin | 10 Stud | 0.470 11.94mm | |||||||||||||||||||||||||||||||||||||||||||||||
| PNF10-6R-D | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2001 | /files/panduitcorp-pnf1010rd-datasheets-6995.pdf | 26.924mm | 9.4mm | Yellow | 9.4mm | 4 Weeks | 1.270059kg | 0.040 1.02mm | EAR99 | Copper | Tin | No | 8536.90.40.00 | Serrated Termination | RING TERMINAL | 10-12 AWG | 10 AWG | 12 AWG | Circular | 1.060 26.92mm | Insulated | 0.120 ~ 0.225 (3.05mm ~ 5.72mm) | Polyamide (PA), Nylon | 6 Stud | 0.370 9.40mm | |||||||||||||||||||||||||||||||
| 8-36158-1 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | PIDG | Free Hanging | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 2009 | 21.8186mm | 300V | Blue | Lead Free | 8.71mm | 8 Weeks | ACTIVE (Last Updated: 1 week ago) | Compliant | 0.031 0.79mm | Straight | EAR99 | Copper | Tin | 8536.90.40.00 | Serrated Termination | RING TERMINAL | 14-16 AWG | 2.62 mm2 | 16 AWG | 14 AWG | Circular | 0.859 21.82mm | 4.318 mm | Insulated | 0.105 ~ 0.170 (2.67mm ~ 4.32mm) | Yes | 2.54μm | No | 3.68 mm | 790μm | Polyamide (PA), Nylon | 6 Stud | 1 | M3.5 | 0.343 8.71mm | 790μm | ||||||||||||||||||||
| 8-320882-1 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | PIDG | Free Hanging | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 2009 | /files/teconnectivityamp-83208821-datasheets-2361.pdf | 16.99mm | 300V | Red | Not Applicable | 13 Weeks | Unknown | ACTIVE (Last Updated: 4 days ago) | yes | Compliant | 0.031 0.79mm | EAR99 | Copper | 8536.90.40.00 | Serrated Termination | RING TERMINAL | 16-22 AWG | 16 AWG | 22 AWG | Circular | 0.669 16.99mm | 3.56 mm | FEMALE | Insulated | 0.105 ~ 0.140 (2.67mm ~ 3.56mm) | Yes | Tin | No | 3.0226 mm | 790μm | Polyamide (PA), Nylon | 4 Stud | 1 | M2.5 | 0.182 4.62mm | 790μm | ||||||||||||||||||||
| RV14-10Q | 3M |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Highland™ | Free Hanging | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | ROHS3 Compliant | 2000 | /files/3m-rv188q-datasheets-9408.pdf | 22.86mm | 114.3mm | 139.7mm | Blue | 3 Weeks | 317.514659g | CSA, UL | Unknown | 0.030 0.76mm | Straight | Copper, ETP | 14 AWG | Butted Seam | 14-16 AWG | 16 AWG | 14 AWG | Circular | 0.900 22.86mm | Insulated | 0.170 (4.32mm) | Tin | Vinyl | 10 Stud | 0.330 8.38mm | |||||||||||||||||||||||||||||||
| 0190580063 | Molex |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Avikrimp | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | ROHS3 Compliant | /files/molex-0190580063-datasheets-0590.pdf | Yellow | 4 Weeks | yes | 0.050 1.27mm | EAR99 | Copper | 8536.90.40.00 | Heavy Duty | RING TERMINAL | 14-16 AWG | 2 mm2 | Circular | 1.258 31.95mm | Insulated | 0.225 (5.72mm) | Electro-Tin | Polyamide (PA), Nylon | 1/4 Stud | 0.530 13.46mm | ||||||||||||||||||||||||||||||||||||||
| PV14-6R-C | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2002 | /files/panduit-pv146rc-datasheets-2319.pdf | 23.4mm | Blue | 7.9mm | 4 Weeks | 117.934016g | No SVHC | 0.032 0.81mm | Straight | EAR99 | Copper | Tin | No | 8536.90.40.00 | 14 AWG | Brazed Seam | RING TERMINAL | 14-16 AWG | 16 AWG | 14 AWG | Circular | 0.920 23.37mm | FEMALE | Insulated | 0.170 (4.32mm) | Vinyl | 6 Stud | 0.310 7.87mm | ||||||||||||||||||||||||||||
| PV12-56HDR-D | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2001 | /files/panduitcorp-pv1214hdrd-datasheets-9356.pdf | 31.242mm | 13.2mm | Yellow | 13.21mm | 4 Weeks | 0.050 1.27mm | EAR99 | Copper | Tin | No | 8536.90.40.00 | Brazed Seam, Heavy Duty, Serrated Termination | RING TERMINAL | 12-16 AWG | 16 AWG | 12 AWG | Circular | 1.230 31.24mm | Insulated | 0.225 (5.72mm) | Vinyl | 5/16 Stud | 0.520 13.21mm | ||||||||||||||||||||||||||||||||
| 8-320574-1 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | PIDG | Free Hanging, Stud | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 2008 | /files/teconnectivityampconnectors-23205742-datasheets-3531.pdf | 21.62mm | 300V | Blue | Not Applicable | 7 Weeks | No SVHC | ACTIVE (Last Updated: 1 week ago) | yes | Female | Compliant | 0.031 0.79mm | Straight | EAR99 | Copper | 8536.90.40.00 | 14 AWG | Serrated Termination | RING TERMINAL | 14-16 AWG | 2 mm2 | 14 AWG | 16 AWG | Circular | 0.859 21.82mm | 3.81 mm | Insulated | 0.105 ~ 0.150 (2.67mm ~ 3.81mm) | Yes | Tin | No | 4.82 mm | Polyamide (PA), Nylon | 10 Stud | 1 | 0.343 8.71mm | 840μm | |||||||||||||||||||
| PV10-38RX-D | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2001 | https://pdf.utmel.com/r/datasheets/panduit-pv1038rxd-datasheets-2281.pdf | 35.306mm | 14.7mm | Yellow | Copper | 14.73mm | 4 Weeks | 0.040 1.02mm | Copper | Tin | No | Brazed Seam, Serrated Termination | Copper | Tin | 10-12 AWG | 12 AWG | 10 AWG | Circular | 1.390 35.31mm | Insulated | 0.250 (6.35mm) | Tin | Vinyl | 3/8 Stud | 0.580 14.73mm | |||||||||||||||||||||||||||||||
| 8-34853-1 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Plasti-Grip | Stud | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 2009 | /files/teconnectivityampconnectors-34853-datasheets-9890.pdf | 27.94mm | 600V | Yellow | Lead Free | 9.52mm | 12 Weeks | Unknown | ACTIVE (Last Updated: 3 days ago) | Compliant | 0.040 1.02mm | Straight | EAR99 | Copper | Tin | 8536.90.40.00 | Serrated Termination | RING TERMINAL | 10-12 AWG | 6.64 mm2 | 10 AWG | 12 AWG | Circular | 1.098 27.89mm | 6.35 mm | FEMALE | Insulated | 0.150 ~ 0.250 (3.81mm ~ 6.35mm) | Yes | 2.54μm | No | 4.34 mm | 1mm | Poly-Vinyl Chloride (PVC) | 8 Stud | 1 | M4 | 0.375 9.53mm | 1.0668mm | |||||||||||||||||
| 8-33461-1 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Solistrand | Free Hanging | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 2004 | /files/teconnectivity-8334611-datasheets-2285.pdf | 23.7mm | Not Applicable | 14 Weeks | ACTIVE (Last Updated: 4 days ago) | yes | Compliant | 0.048 1.22mm | 4.37 mm | EAR99 | Copper | 8536.90.40.00 | 8 AWG | Brazed Seam, Serrated Termination | RING TERMINAL | 8 AWG | Circular | 0.933 23.70mm | FEMALE | Non-Insulated | Tin | No | 6.731 mm | 1.2192mm | 1/4 Stud | 1 | M6 | 0.469 11.91mm | 1.22mm |
Please send RFQ , we will respond immediately.