Compare | Image | Name | Manufacturer | Pricing(USD) | Quantity | Weight(Kg) | Size(LxWxH) | Part Status | Series | Mount | Mounting Type | Packaging | Moisture Sensitivity Level (MSL) | Termination | RoHS Status | Published | Datasheet | Package / Case | Length | Width | Voltage - Rated AC | Color | Lead Free | Depth | Factory Lead Time | Weight | REACH SVHC | Lifecycle Status | Pbfree Code | Gender | ELV | Thickness | Orientation | ECCN Code | Contact Material | Contact Plating | Radiation Hardening | Reach Compliance Code | HTS Code | Wire/Cable Gauge | Feature | Body Material | Thread Size | Terminal and Terminal Block Type | Body Plating | Wire Gauge | Wire Cross Section | Wire Gauge (Max) | Wire Gauge (Min) | Terminal Type | Length - Overall | Wire/Cable Diameter | Terminal Gender | Insulation | Insulation Diameter | Insulated Wire Support | Contact Finish | Plating Thickness | Heavy Duty | Stud Diameter | Material Thickness | Material - Insulation | Stud/Tab Size | Number of Holes | Stud Size | Width - Outer Edges | Tongue Thickness |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
PV10-8R-E | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2009 | 26.67mm | Yellow | 4 Weeks | 0.040 1.02mm | Copper | Tin | No | Brazed Seam | 10-12 AWG | 12 AWG | 10 AWG | Circular | 1.050 26.67mm | Insulated | 0.225 (5.72mm) | Tin | Vinyl | 8 Stud | 0.310 7.87mm | |||||||||||||||||||||||||||||||||||
PV14-14RX-L | Panduit Corp | $1.20 |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2001 | https://pdf.utmel.com/r/datasheets/panduitcorp-pv148rxm-datasheets-8599.pdf | 29.464mm | Blue | 4 Weeks | 0.032 0.81mm | EAR99 | Copper | 8536.90.40.00 | Brazed Seam, Serrated Termination | RING TERMINAL | 14-16 AWG | 16 AWG | 14 AWG | Circular | 1.160 29.46mm | Insulated | 0.200 (5.08mm) | Tin | Vinyl | 1/4 Stud | 0.460 11.68mm | ||||||||||||||||||||||||||||||||
8-320564-1 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | PIDG | Free Hanging | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 2011 | /files/teconnectivityamp-83205641-datasheets-5302.pdf | 32.512mm | 300V | Blue | Not Applicable | 15 Weeks | ACTIVE (Last Updated: 4 months ago) | yes | Compliant | 0.031 0.79mm | Straight | EAR99 | Copper | 8536.90.40.00 | Serrated Termination | WIRE TERMINAL | 14-16 AWG | 16 AWG | 14 AWG | Circular | 1.218 30.94mm | 3.81 mm | FEMALE | Insulated | 0.105 ~ 0.150 (2.67mm ~ 3.81mm) | Yes | Tin | No | 9.525 mm | Polyamide (PA), Nylon | 3/8 Stud | 1 | 0.531 13.49mm | 840μm | ||||||||||||||||||||
A4-56R-C | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | /files/panduitcorp-a414rc-datasheets-3588.pdf | Silver | 4 Weeks | 0.060 1.52mm | Copper | 4 AWG | Circular Tubular (Battery Lugs) | 1.630 41.40mm | Non-Insulated | Electro-Tin | 5/16 Stud | 0.610 15.49mm | |||||||||||||||||||||||||||||||||||||||||||||
PV18-56R-CY | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2001 | /files/panduitcorp-pv188rmy-datasheets-7112.pdf | 28.194mm | Red | 4 Weeks | 122.46994g | No SVHC | 0.032 0.81mm | EAR99 | Copper | No | 8536.90.40.00 | 18 AWG | Brazed Seam | RING TERMINAL | 18-22 AWG | 22 AWG | 18 AWG | Circular | 1.110 28.19mm | Insulated | 0.150 (3.81mm) | Tin | Vinyl | 5/16 Stud | 0.460 11.68mm | |||||||||||||||||||||||||||||
P12-10HDR-L | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2007 | 20.574mm | 9.4mm | 9.4mm | 4 Weeks | 0.050 1.27mm | EAR99 | Copper | Tin | No | 8536.90.40.00 | Brazed Seam, Heavy Duty | RING TERMINAL | 12-16 AWG | 16 AWG | 12 AWG | Circular | 0.810 20.57mm | FEMALE | Non-Insulated | 10 Stud | 0.370 9.40mm | |||||||||||||||||||||||||||||||||
MNG10-8RK | 3M |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Scotchlok™ | Free Hanging | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 2000 | 26.162mm | Yellow | 9.65mm | 3 Weeks | 1.152125kg | 0.040 1.02mm | Copper, ETP | Tin | Copper | Tin | 10-12 AWG | 12 AWG | 10 AWG | Circular | 1.030 26.16mm | Insulated | 0.250 (6.35mm) | Tin | Polyamide (PA), Nylon | 8 Stud | 0.380 9.65mm | |||||||||||||||||||||||||||||||||
0190710192 | Molex |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | InsulKrimp | Free Hanging | Free Hanging (In-Line) | Tape & Reel (TR) | 1 (Unlimited) | Crimp | ROHS3 Compliant | /files/molex-0190710192-datasheets-8648.pdf | 42.3418mm | Blue | 16.4mm | 6 Weeks | yes | 0.050 1.27mm | Copper Alloy | unknown | 6 AWG | Copper | RING TERMINAL | Tin | 6 AWG | Circular | 1.667 42.34mm | Insulated | 0.440 (11.18mm) | Electro-Tin | Poly-Vinyl Chloride (PVC) | 1/4 Stud | 0.638 16.21mm | |||||||||||||||||||||||||||||||||
P12-38HDR-L | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2007 | 600 | 26.416mm | 14.7mm | 14.73mm | 4 Weeks | 0.050 1.27mm | EAR99 | Copper | No | 8536.90.40.00 | Brazed Seam, Heavy Duty | RING TERMINAL | 12-16 AWG | 16 AWG | 12 AWG | Circular | 1.040 26.42mm | FEMALE | Non-Insulated | Tin | 3/8 Stud | 0.580 14.73mm | ||||||||||||||||||||||||||||||||
P18-12R-C | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2008 | /files/panduit-p1812rc-datasheets-5271.pdf | 30.48mm | Red | 18.3mm | 4 Weeks | 108.862169g | No SVHC | 0.030 0.76mm | Straight | Copper | Tin | No | 18 AWG | Brazed Seam, Serrated Termination | Copper | Tin | 18-22 AWG | 22 AWG | 18 AWG | Circular | 1.200 30.48mm | Non-Insulated | Tin | 1/2 Stud | 0.720 18.29mm | |||||||||||||||||||||||||||||
PV14-6R-E | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2009 | 23.368mm | Blue | 4 Weeks | 0.032 0.81mm | Copper | Tin | No | Brazed Seam, Serrated Termination | 14-16 AWG | 16 AWG | 14 AWG | Circular | 0.920 23.37mm | Insulated | 0.170 (4.32mm) | Tin | Vinyl | 6 Stud | 0.310 7.87mm | |||||||||||||||||||||||||||||||||||
PV14-10R-E | Panduit Corp | $0.27 |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2002 | https://pdf.utmel.com/r/datasheets/panduitcorp-pv146rnm-datasheets-8391.pdf | 23.368mm | Blue | 4 Weeks | 0.032 0.81mm | Copper | Tin | No | Brazed Seam, Serrated Termination | 14-16 AWG | 16 AWG | 14 AWG | Circular | 0.920 23.37mm | Insulated | 0.170 (4.32mm) | Tin | Vinyl | 10 Stud | 0.310 7.87mm | |||||||||||||||||||||||||||||||||
A8-14R-C | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | /files/panduitcorp-a414rc-datasheets-3588.pdf | Silver | 4 Weeks | 0.050 1.27mm | Copper | 8 AWG | Circular Tubular (Battery Lugs) | 1.320 33.53mm | Non-Insulated | Electro-Tin | 1/4 Stud | 0.430 10.92mm | |||||||||||||||||||||||||||||||||||||||||||||
A4-38R-C | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | /files/panduitcorp-a414rc-datasheets-3588.pdf | Silver | 4 Weeks | 0.060 1.52mm | Copper | 4 AWG | Circular Tubular (Battery Lugs) | 1.730 43.94mm | Non-Insulated | Electro-Tin | 3/8 Stud | 0.610 15.49mm | |||||||||||||||||||||||||||||||||||||||||||||
8-36161-2 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | PIDG | Free Hanging | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 1999 | /files/teconnectivityampconnectors-2361616-datasheets-7366.pdf | 27.51mm | 300V | Yellow | Not Applicable | 9.52mm | 5 Weeks | ACTIVE (Last Updated: 1 day ago) | yes | Female | Compliant | 0.039 0.99mm | Straight | EAR99 | Copper | Tin | 8536.90.40.00 | Serrated Termination | RING TERMINAL | 10-12 AWG | 12 AWG | 10 AWG | Circular | 1.083 27.51mm | 5.842 mm | Insulated | 0.105 ~ 0.230 (2.67mm ~ 5.84mm) | Yes | 2.54μm | No | 5 mm | 990.6μm | Polyamide (PA), Nylon | 10 Stud | 1 | 0.375 9.53mm | 990μm | |||||||||||||||||
PV18-6R-E | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2006 | /files/panduit-pv186re-datasheets-5252.pdf | 21.844mm | Red | 6.4mm | 4 Weeks | 0.032 0.81mm | Copper | Tin | No | Brazed Seam, Serrated Termination | Copper | Tin | 18-22 AWG | 22 AWG | 18 AWG | Circular | 0.860 21.84mm | Insulated | 0.150 (3.81mm) | Tin | Vinyl | 6 Stud | 0.250 6.35mm | |||||||||||||||||||||||||||||||
A8-38R-C | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | /files/panduitcorp-a414rc-datasheets-3588.pdf | Silver | 4 Weeks | 0.040 1.02mm | Copper | 8 AWG | Circular Tubular (Battery Lugs) | 1.540 39.12mm | Non-Insulated | Electro-Tin | 3/8 Stud | 0.540 13.72mm | |||||||||||||||||||||||||||||||||||||||||||||
8-32961-1 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Plasti-Grip | Free Hanging | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 2004 | /files/teconnectivityamp-8329611-datasheets-5255.pdf | 27.686mm | 600V | Blue | Not Applicable | 10 Weeks | ACTIVE (Last Updated: 6 days ago) | Compliant | 0.031 0.79mm | EAR99 | Copper | 8536.90.40.00 | Serrated Termination | RING TERMINAL | 14-16 AWG | 2.62 mm2 | 16 AWG | 14 AWG | Circular | 1.090 27.69mm | 3.683 mm | FEMALE | Insulated | 0.105 ~ 0.145 (2.67mm ~ 3.68mm) | Yes | Tin | No | 6.35 mm | 790μm | Poly-Vinyl Chloride (PVC) | 1/4 Stud | 1 | M6 | 0.469 11.91mm | 840μm | |||||||||||||||||||
PV18-10R-E | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2009 | /files/panduit-pv1810re-datasheets-5258.pdf | 23.876mm | Red | 4 Weeks | 0.032 0.81mm | Copper | Tin | No | Brazed Seam, Serrated Termination | 18-22 AWG | 22 AWG | 18 AWG | Circular | 0.940 23.88mm | Insulated | 0.150 (3.81mm) | Tin | Vinyl | 10 Stud | 0.310 7.87mm | ||||||||||||||||||||||||||||||||||
P12-6HDR-L | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2007 | 19.812mm | 7.874mm | 4 Weeks | 99.790321g | No SVHC | 0.050 1.27mm | EAR99 | Copper | No | 8536.90.40.00 | 12 AWG | Brazed Seam, Heavy Duty | RING TERMINAL | 12-16 AWG | 16 AWG | 12 AWG | Circular | 0.780 19.81mm | FEMALE | Non-Insulated | Tin | 6 Stud | 0.310 7.87mm | |||||||||||||||||||||||||||||||
P8-10RHT6-T | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2009 | /files/panduit-p810rht6t-datasheets-5262.pdf | 28.956mm | 10.67mm | 4 Weeks | 0.040 1.02mm | EAR99 | Copper | No | 8536.90.40.00 | 8 AWG | Brazed Seam | RING TERMINAL | 8 AWG | D-Shaped | 1.140 28.96mm | Non-Insulated | Nickel | 10 Stud | 0.420 10.67mm | |||||||||||||||||||||||||||||||||||
PV18-4RX-CY | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2005 | /files/panduit-pv184rxcy-datasheets-5234.pdf | 22.352mm | Red | 6.35mm | 4 Weeks | 0.030 0.76mm | EAR99 | Copper | Tin | No | 8536.90.40.00 | Brazed Seam, Serrated Termination | RING TERMINAL | 18-22 AWG | 22 AWG | 18 AWG | Circular | 0.880 22.35mm | Insulated | 0.170 (4.32mm) | Vinyl | 4 Stud | 0.250 6.35mm | |||||||||||||||||||||||||||||||
PNF10-38R-D | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2001 | /files/panduitcorp-pnf1010rd-datasheets-6995.pdf | 32.766mm | 14.7mm | Yellow | 14.73mm | 4 Weeks | 0.040 1.02mm | EAR99 | Copper | Tin | No | 8536.90.40.00 | Serrated Termination | RING TERMINAL | 10-12 AWG | 12 AWG | 10 AWG | Circular | 1.290 32.77mm | Insulated | 0.120 ~ 0.225 (3.05mm ~ 5.72mm) | Polyamide (PA), Nylon | 3/8 Stud | 0.580 14.73mm | ||||||||||||||||||||||||||||||
0190710227 | Molex |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | InsulKrimp | Free Hanging (In-Line) | Tape & Reel (TR) | 1 (Unlimited) | Crimp | ROHS3 Compliant | /files/molex-0190710227-datasheets-8557.pdf | Blue | 4 Weeks | yes | 0.050 1.27mm | Copper Alloy | RING TERMINAL | 6 AWG | Circular | 1.596 40.54mm | Insulated | 0.440 (11.18mm) | Electro-Tin | Poly-Vinyl Chloride (PVC) | 1/4 Stud | 0.485 12.32mm | ||||||||||||||||||||||||||||||||||||||||
PV18-8R-E | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2009 | /files/panduit-pv188re-datasheets-5239.pdf | 23.114mm | Red | 4 Weeks | 0.032 0.81mm | Copper | Tin | No | Brazed Seam, Serrated Termination | 18-22 AWG | 22 AWG | 18 AWG | Circular | 0.910 23.11mm | Insulated | 0.150 (3.81mm) | Tin | Vinyl | 8 Stud | 0.310 7.87mm | ||||||||||||||||||||||||||||||||||
15-38-W | 3M |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Free Hanging | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | ROHS3 Compliant | 2002 | https://pdf.utmel.com/r/datasheets/3m-1538w-datasheets-8497.pdf | Blue | 3 Weeks | 4.850008g | 0.050 1.27mm | Copper, ETP | 6 AWG | Brazed Seam | 6 AWG | Circular | 1.220 30.99mm | Non-Insulated | Tin | 3/8 Stud | 0.630 16.00mm | ||||||||||||||||||||||||||||||||||||||||
PV14-6RX-C | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2001 | /files/panduitcorp-pv148rxm-datasheets-8599.pdf | 24.384mm | 7.874mm | Blue | 4 Weeks | 117.934016g | Female | 0.032 0.81mm | EAR99 | Copper | No | 8536.90.40.00 | Brazed Seam, Serrated Termination | RING TERMINAL | 14-16 AWG | 16 AWG | 14 AWG | Circular | 0.960 24.38mm | Insulated | 0.200 (5.08mm) | Tin | Vinyl | 6 Stud | 0.310 7.87mm | |||||||||||||||||||||||||||||
PV18-10RX-CY | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2005 | /files/panduit-pv1810rxcy-datasheets-5227.pdf | 24.384mm | Red | 4 Weeks | 104.326245g | 0.030 0.76mm | EAR99 | Copper | No | 8536.90.40.00 | Brazed Seam, Serrated Termination | RING TERMINAL | 18-22 AWG | 22 AWG | 18 AWG | Circular | 0.960 24.38mm | Insulated | 0.170 (4.32mm) | Tin | Vinyl | 10 Stud | 0.310 7.87mm | |||||||||||||||||||||||||||||||
0190690101 | Molex |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Krimptite | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | ROHS3 Compliant | /files/molex-0190690101-datasheets-7716.pdf | 5 Weeks | yes | 0.031 0.79mm | EAR99 | Copper | 8536.90.40.00 | RING TERMINAL | 14-16 AWG | 2 mm2 | Circular | 0.560 14.22mm | Non-Insulated | Tin | 6 Stud | 0.260 6.60mm | ||||||||||||||||||||||||||||||||||||||||
5580625 | Würth Elektronik |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | WA-CLUG | Free Hanging | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | ROHS3 Compliant | /files/wrthelektronik-5580625-datasheets-7772.pdf | 29.9974mm | 7 Weeks | Copper Alloy | Tin | 25 AWG | M6 | Circular Tubular (Battery Lugs) | 1.181 30.00mm | Non-Insulated | Tin | M6 Stud | 0.551 14.00mm |
Please send RFQ , we will respond immediately.