Compare | Image | Name | Manufacturer | Pricing(USD) | Quantity | Weight(Kg) | Size(LxWxH) | Part Status | Series | Mount | Mounting Type | Packaging | Moisture Sensitivity Level (MSL) | Termination | Max Operating Temperature | Min Operating Temperature | RoHS Status | Published | Datasheet | Package / Case | Length | Color | Lead Free | Depth | Factory Lead Time | Weight | Lifecycle Status | Pbfree Code | Gender | Number of Contacts | ELV | Diameter - Inside | Orientation | ECCN Code | Contact Material | Contact Plating | Radiation Hardening | HTS Code | Wire/Cable Gauge | Feature | Number of Circuits | Body Material | Terminal and Terminal Block Type | Safety Approval | Body Plating | Number of Rows | Wire Gauge | Wire Cross Section | Wire Gauge (Max) | Wire Gauge (Min) | Terminal Type | Length - Overall | Terminal Gender | Insulation | Tab Thickness | Contact Finish | Plating Thickness | Heavy Duty | Stud Diameter | Material Thickness | Stud/Tab Size | Number of Holes | Stud Size | Width - Outer Edges | Tongue Thickness | Diameter - Barrel OD | Diameter - Barrel ID | Terminal Style | Diameter - Ring ID |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
LCAX350-38F-6 | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Free Hanging | Free Hanging (In-Line), Right Angle | Bulk | Not Applicable | Crimp, Barrel | ROHS3 Compliant | 2004 | 58.9mm | Blue | Lead Free | 39.1mm | 4 Weeks | yes | EAR99 | Copper | No | 8536.90.40.00 | WIRE TERMINAL | Tin | 350MCM (kcmil) | Rectangular Tongue | Non-Insulated | 0.220 5.59mm | Electro-Tin | 3/8 Stud | 1.540 39.12mm | 1.060 (26.92mm) | 0.840 (21.34mm) | Single Stud Hole | 0.410 (10.41mm) | |||||||||||||||||||||||||||||||||
LCA500-12H-6 | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Free Hanging | Free Hanging (In-Line), 45° Angle | Bulk | Not Applicable | Crimp, Barrel | ROHS3 Compliant | 2004 | Brown | 4 Weeks | EAR99 | Copper | Tin | No | 8536.90.40.00 | WIRE TERMINAL | 500MCM (kcmil) | Rectangular Tongue | FEMALE | Non-Insulated | 0.220 5.59mm | Electro-Tin | 1/2 Stud | 1.540 39.12mm | 1.060 (26.92mm) | 0.840 (21.34mm) | Single Stud Hole | 0.530 (13.46mm) | ||||||||||||||||||||||||||||||||||||
LAA350-12-2 | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | LAA | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp, Barrel | ROHS3 Compliant | 2016 | https://pdf.utmel.com/r/datasheets/panduitcorp-laa1000581-datasheets-9992.pdf | 108.7374mm | 4 Weeks | EAR99 | Aluminum | No | 8536.90.40.00 | Gel Filled | WIRE TERMINAL | 350MCM (kcmil) | 177.3 mm2 | Rectangular Tongue | 4.281 107.74mm | FEMALE | Non-Insulated | 0.375 9.53mm | Tin | 1/2 Stud | 1.500 38.10mm | 1.050 (26.67mm) | 0.720 (18.29mm) | Single Stud Hole | ||||||||||||||||||||||||||||||||||
LCMA240-12-X | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp, Barrel | ROHS3 Compliant | 2005 | https://pdf.utmel.com/r/datasheets/panduitcorp-lcmax300105-datasheets-9802.pdf | 86.5124mm | 37.5mm | 4 Weeks | 1.433352kg | EAR99 | Copper | Tin | No | 8536.90.40.00 | RING TERMINAL | 240mm2 | Ring, Tubular | 3.406 86.51mm | Non-Insulated | 0.209 5.31mm | M12 Stud | 1.476 37.49mm | 1.024 (26.01mm) | 0.819 (20.80mm) | Single Stud Hole | 0.551 (14.00mm) | ||||||||||||||||||||||||||||||||||
LCMA240-16F-X | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Free Hanging | Free Hanging (In-Line), Right Angle | Bulk | Not Applicable | Crimp, Barrel | ROHS3 Compliant | 2013 | 4 Weeks | Copper | Tin | 240mm2 | Ring, Tubular | Non-Insulated | 0.209 5.31mm | Tin | M16 Stud | 1.476 37.49mm | 1.024 (26.01mm) | 0.819 (20.80mm) | Single Stud Hole | 0.709 (18.01mm) | ||||||||||||||||||||||||||||||||||||||||||
LAM2B350-12-3Y | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | LAM2B | Cable, Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Screw | ROHS3 Compliant | 2010 | 106.426mm | 4 Weeks | 2 | Right Angle | Aluminum | Tin | No | 2 Cable Entries, With Screw | 2 | 1 | 350MCM (kcmil)-6 AWG | Lug, Grounding | 4.190 106.43mm | Non-Insulated | 0.250 6.35mm | Tin | 1/2 Stud | 1.940 49.28mm | Two Stud Holes | 0.680 (17.27mm) | ||||||||||||||||||||||||||||||||||||
LCD500-12-6 | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp, Barrel | ROHS3 Compliant | 2004 | 136.398mm | Brown | 39.1mm | 4 Weeks | EAR99 | Copper | No | 8536.90.40.00 | RING TERMINAL | Tin | 500MCM (kcmil) | 253.3 mm2 | Rectangular Tongue | 5.370 136.40mm | Non-Insulated | 0.220 5.59mm | Electro-Tin | 1/2 Stud | 1.540 39.12mm | 1.060 (26.92mm) | 0.840 (21.34mm) | Two Stud Holes | 0.530 (13.46mm) | |||||||||||||||||||||||||||||||||
LCAN500-12-6 | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp, Barrel | ROHS3 Compliant | 2011 | 90.678mm | Brown | 26.9mm | 4 Weeks | EAR99 | Copper | No | 8536.90.40.00 | WIRE TERMINAL | Tin | 500MCM (kcmil) | Rectangular Tongue | 3.570 90.68mm | FEMALE | Non-Insulated | 0.260 6.60mm | Electro-Tin | 1/2 Stud | 1.060 26.92mm | 1.060 (26.92mm) | 0.840 (21.34mm) | Single Stud Hole | 0.530 (13.46mm) | |||||||||||||||||||||||||||||||||
53686-2 | TE Connectivity AMP Connectors | $63.98 |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Ampower | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp, Barrel | RoHS Compliant | 2004 | 161.29mm | Lead Free | 17 Weeks | ACTIVE (Last Updated: 3 days ago) | yes | Compliant | 29.51 mm | EAR99 | Copper | 8536.90.40.00 | WIRE TERMINAL | 700MCM (kcmil) | Standard | 6.350 161.29mm | FEMALE | Non-Insulated | 0.240 6.10mm | Tin | 3.81μm | No | 14.2748 mm | 2.794mm | 1/2 Stud | 2 | M12 | 2.120 53.84mm | 6.1mm | 1.700 (43.18mm) | 1.162 (29.51mm) | Two Stud Holes | 0.562 (14.27mm) | |||||||||||||||||||||||||
LCCX350-12-6 | Panduit Corp | $40.20 |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp, Barrel | ROHS3 Compliant | 2004 | https://pdf.utmel.com/r/datasheets/panduit-lccx350126-datasheets-3688.pdf | 155.702mm | Blue | 4 Weeks | EAR99 | Copper | Tin | No | 8536.90.40.00 | WIRE TERMINAL | 350MCM (kcmil) | Rectangular Tongue | 6.130 155.70mm | FEMALE | Non-Insulated | 0.220 5.59mm | Electro-Tin | 1/2 Stud | 1.540 39.12mm | 1.060 (26.92mm) | 0.840 (21.34mm) | Two Stud Holes | 0.530 (13.46mm) | ||||||||||||||||||||||||||||||||
LCC500-38DW-6 | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp, Barrel | ROHS3 Compliant | 2004 | https://pdf.utmel.com/r/datasheets/panduit-lcc50038dw6-datasheets-3722.pdf | 125 | 125.476mm | Brown | 4 Weeks | EAR99 | Copper | Tin | No | 8536.90.40.00 | WIRE TERMINAL | 500MCM (kcmil) | Rectangular Tongue | 4.940 125.48mm | FEMALE | Non-Insulated | 0.220 5.59mm | Electro-Tin | 3/8 Stud | 1.540 39.12mm | 1.060 (26.92mm) | 0.840 (21.34mm) | Two Stud Holes | 0.410 (10.41mm) | ||||||||||||||||||||||||||||||||
LCDX2/0-14A-X | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp, Barrel | ROHS3 Compliant | 2011 | 65.786mm | Black | 24.4mm | 4 Weeks | 453.59237g | Female | EAR99 | Copper | No | 8536.90.40.00 | WIRE TERMINAL | Tin | 2/0 AWG | Rectangular Tongue | 2.590 65.79mm | Non-Insulated | 0.130 3.30mm | Electro-Tin | 1/4 Stud | 0.960 24.38mm | 0.640 (16.26mm) | 0.510 (12.95mm) | Two Stud Holes | 0.270 (6.86mm) | ||||||||||||||||||||||||||||||||
PNL-500-3 | Panduit Corp | $49.50 |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Screw | ROHS3 Compliant | 2009 | 76.2mm | 35mm | 4 Weeks | EAR99 | Copper Alloy | No | 8536.90.40.00 | With Screw | Copper | WIRE TERMINAL | 500MCM (kcmil)-4 AWG | Lug, Grounding | 3.000 76.20mm | FEMALE | Non-Insulated | 0.250 6.35mm | 1.380 35.05mm | Single Stud Hole | 0.530 (13.46mm) | ||||||||||||||||||||||||||||||||||||
LAB250-12-5 | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | LAB | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp, Barrel | ROHS3 Compliant | 2001 | https://pdf.utmel.com/r/datasheets/panduitcorp-lab40125-datasheets-0387.pdf | 153.67mm | 31.75mm | 4 Weeks | EAR99 | Aluminum | No | 8536.90.40.00 | Gel Filled | Aluminium | RING TERMINAL | CSA; UL | 250MCM (kcmil) | 126.6 mm2 | Rectangular Tongue | 6.050 153.67mm | FEMALE | Non-Insulated | 0.310 7.87mm | Tin | 1/2 Stud | 1.250 31.75mm | 0.906 (23.01mm) | 0.594 (15.09mm) | Two Stud Holes | 0.540 (13.72mm) | ||||||||||||||||||||||||||||||
LAM2A1000-58-6Y | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | LAM2A | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Screw | ROHS3 Compliant | 2010 | https://pdf.utmel.com/r/datasheets/panduitcorp-lam2a250386y-datasheets-5136.pdf | 88.9mm | 4 Weeks | EAR99 | Aluminum | No | 8536.90.40.00 | 2 Cable Entries, With Screw | RING TERMINAL | 500-1000MCM (kcmil) | 645 mm2 | 1000 AWG | 500 AWG | Lug, Grounding | 3.500 88.90mm | Non-Insulated | 0.500 12.70mm | Tin | 5/8 Stud | Single Stud Hole | ||||||||||||||||||||||||||||||||||||
LCAX500-38-6 | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp, Barrel | ROHS3 Compliant | 2011 | https://pdf.utmel.com/r/datasheets/panduit-lcax500386-datasheets-3695.pdf | 83.058mm | Pink | 4 Weeks | EAR99 | Copper | Tin | No | 8536.90.40.00 | RING TERMINAL | 500MCM (kcmil) | 323 mm2 | Rectangular Tongue | 3.270 83.06mm | Non-Insulated | 0.260 6.60mm | Electro-Tin | 3/8 Stud | 1.890 48.01mm | Single Stud Hole | ||||||||||||||||||||||||||||||||||||
LAM2SSB500-141Y | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | LAM2SSB | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Screw | ROHS3 Compliant | 2008 | 73.9mm | 36.6mm | 4 Weeks | 1.000171kg | EAR99 | Aluminum | No | 8536.90.40.00 | 2 Cable Entries, With Screw | Aluminium | RING TERMINAL | 500MCM (kcmil)-4/0 AWG | 107.26 mm2 | Lug, Grounding | FEMALE | Non-Insulated | 0.630 16.00mm | Tin | 1/4 Stud | 1.440 36.58mm | Two Stud Holes | |||||||||||||||||||||||||||||||||||
276916-1 | TE Connectivity AMP Connectors | $44.83 |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Ampower | Free Hanging | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp, Barrel | RoHS Compliant | 2008 | https://pdf.utmel.com/r/datasheets/teconnectivityampconnectors-2769161-datasheets-8981.pdf | 113.28mm | Lead Free | 14 Weeks | ACTIVE (Last Updated: 4 months ago) | yes | Compliant | EAR99 | Copper | 8536.90.40.00 | WIRE TERMINAL | 600MCM (kcmil) | Standard | 4.460 113.28mm | FEMALE | Non-Insulated | 0.220 5.59mm | Tin | No | 13.08 mm | 1/2 Stud | 2 | 1.950 49.53mm | 5.588mm | 1.341 (34.06mm) | 1.075 (27.31mm) | Two Stud Holes | 0.562 (14.27mm) | |||||||||||||||||||||||||||
LAM3B1/0-38-6Y | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | LAM3B | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Screw | ROHS3 Compliant | 2011 | https://pdf.utmel.com/r/datasheets/panduit-lam3b10386y-datasheets-3673.pdf | 73.914mm | 4 Weeks | EAR99 | Aluminum | No | 8536.90.40.00 | 3 Cable Entries, With Screw | Aluminium | WIRE TERMINAL | 1/0-14 AWG | 53.51 mm2 | 14 AWG | 0 AWG | Lug, Grounding | 2.910 73.91mm | FEMALE | Non-Insulated | 0.250 6.35mm | Tin | 3/8 Stud | 2.000 50.80mm | Two Stud Holes | |||||||||||||||||||||||||||||||||
325926-1 | TE Connectivity AMP Connectors | $41.14 |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Ampower | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp, Barrel | 105°C | -55°C | RoHS Compliant | 2016 | https://pdf.utmel.com/r/datasheets/teconnectivityampconnectors-3259261-datasheets-8927.pdf | 101.85mm | 17 Weeks | ACTIVE (Last Updated: 4 months ago) | yes | Compliant | 21.06 mm | EAR99 | Copper | 8536.90.40.00 | RING TERMINAL | 350MCM (kcmil) | Rectangular Tongue | 4.010 101.85mm | FEMALE | Non-Insulated | 0.170 4.32mm | Tin | No | 14.2748 mm | 1/2 Stud | 2 | M12 | 1.510 38.35mm | 4.318mm | 1.026 (26.06mm) | 0.829 (21.06mm) | Two Stud Holes | 0.562 (14.27mm) | |||||||||||||||||||||||||
LCA750-12-6 | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Not Applicable | ROHS3 Compliant | 4 Weeks | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
LCD500-12E-6 | Panduit Corp | $26.73 |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp, Barrel | ROHS3 Compliant | 2004 | 120 | 120.396mm | Brown | 4 Weeks | EAR99 | Copper | Tin | No | 8536.90.40.00 | RING TERMINAL | 500MCM (kcmil) | Rectangular Tongue | 4.740 120.40mm | Non-Insulated | 0.220 5.59mm | Electro-Tin | 1/2 Stud | 1.540 39.12mm | 1.060 (26.92mm) | 0.840 (21.34mm) | Two Stud Holes | 0.530 (13.46mm) | |||||||||||||||||||||||||||||||||
HL1-2-25-X | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | HL | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Screw | ROHS3 Compliant | 50.8mm | 4 Weeks | EAR99 | Copper Alloy | No | 8536.90.40.00 | 8 AWG | With Screw | WIRE TERMINAL | 8-14 AWG | 14 AWG | 8 AWG | Lug, Grounding | 2.000 50.80mm | FEMALE | Non-Insulated | 0.190 4.83mm | 1/4 Stud | 0.560 14.22mm | Two Stud Holes | |||||||||||||||||||||||||||||||||||||
LCA600-12-6 | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp, Barrel | ROHS3 Compliant | 2004 | 600 | 106.426mm | Green | 4 Weeks | 1.499123kg | yes | Female | EAR99 | Copper | Tin | No | 8536.90.40.00 | RING TERMINAL | 600MCM (kcmil) | 304 mm2 | Rectangular Tongue | 4.190 106.43mm | Non-Insulated | 0.260 6.60mm | Electro-Tin | 1/2 Stud | 1.700 43.18mm | 1.190 (30.23mm) | 0.920 (23.37mm) | Single Stud Hole | 0.530 (13.46mm) | ||||||||||||||||||||||||||||||
LCA500-38F-6 | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Free Hanging | Free Hanging (In-Line), Right Angle | Bulk | Not Applicable | Crimp, Barrel | ROHS3 Compliant | 2004 | 58.9mm | Brown | 39.1mm | 4 Weeks | yes | EAR99 | Copper | No | 8536.90.40.00 | WIRE TERMINAL | Tin | 500MCM (kcmil) | Rectangular Tongue | Non-Insulated | 0.220 5.59mm | Electro-Tin | 3/8 Stud | 1.540 39.12mm | 1.060 (26.92mm) | 0.840 (21.34mm) | Single Stud Hole | 0.410 (10.41mm) | ||||||||||||||||||||||||||||||||||
LCDN500-38D-6 | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp, Barrel | ROHS3 Compliant | 2004 | 106.68mm | Brown | 26.9mm | 4 Weeks | EAR99 | Copper | No | 8536.90.40.00 | WIRE TERMINAL | Tin | 500MCM (kcmil) | Rectangular Tongue | 4.200 106.68mm | FEMALE | Non-Insulated | 0.220 5.59mm | Electro-Tin | 3/8 Stud | 1.060 26.92mm | 1.060 (26.92mm) | 0.840 (21.34mm) | Two Stud Holes | 0.410 (10.41mm) | |||||||||||||||||||||||||||||||||
LAA400-58-2R | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Not Applicable | ROHS3 Compliant | 4 Weeks | EAR99 | 8536.90.40.00 | RING TERMINAL | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
LCA500-12F-6 | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Free Hanging | Free Hanging (In-Line), Right Angle | Bulk | Not Applicable | Crimp, Barrel | ROHS3 Compliant | 2004 | 63mm | Brown | 39.1mm | 4 Weeks | yes | EAR99 | Copper | No | 8536.90.40.00 | WIRE TERMINAL | Tin | 500MCM (kcmil) | Rectangular Tongue | Non-Insulated | 0.220 5.59mm | Electro-Tin | 1/2 Stud | 1.540 39.12mm | 1.060 (26.92mm) | 0.840 (21.34mm) | Single Stud Hole | 0.530 (13.46mm) | ||||||||||||||||||||||||||||||||||
LCAX450-58-6 | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp, Barrel | ROHS3 Compliant | 2004 | https://pdf.utmel.com/r/datasheets/panduit-lcax450586-datasheets-3686.pdf | 94.742mm | Brown | 43.2mm | 4 Weeks | yes | EAR99 | Copper | No | 8536.90.40.00 | WIRE TERMINAL | Tin | 450MCM (kcmil) | Rectangular Tongue | 3.730 94.74mm | Non-Insulated | 0.260 6.60mm | Electro-Tin | 5/8 Stud | 1.700 43.18mm | 1.190 (30.23mm) | 0.920 (23.37mm) | Single Stud Hole | 0.660 (16.76mm) | ||||||||||||||||||||||||||||||||
LCC500-12W-6 | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp, Barrel | ROHS3 Compliant | 2004 | 155.448mm | Brown | 39.1mm | 4 Weeks | EAR99 | Copper | No | 8536.90.40.00 | WIRE TERMINAL | Tin | 500MCM (kcmil) | Rectangular Tongue | 6.120 155.45mm | FEMALE | Non-Insulated | 0.220 5.59mm | Electro-Tin | 1/2 Stud | 1.540 39.12mm | 1.060 (26.92mm) | 0.840 (21.34mm) | Two Stud Holes | 0.530 (13.46mm) |
Please send RFQ , we will respond immediately.