Compare Image Name Manufacturer Pricing(USD) Quantity Weight(Kg) Size(LxWxH) Part Status Series Mount Mounting Type Packaging Moisture Sensitivity Level (MSL) Termination RoHS Status Published Datasheet Diameter Package / Case Length Width Color Lead Free Material Depth Factory Lead Time Weight REACH SVHC Lifecycle Status Pbfree Code Gender ELV Sealable Orientation ECCN Code Contact Material Contact Plating Radiation Hardening HTS Code Wire/Cable Gauge Feature Body Material Insulation Material Terminal and Terminal Block Type Body Plating Wire Gauge Wire Cross Section Wire Gauge (Max) Wire Gauge (Min) Terminal Type Hole Diameter Length - Overall Wire/Cable Diameter Terminal Material Insulation Insulation Diameter Mating Tab Width Tab Thickness Plating Insulated Wire Support Contact Finish Plating Thickness Width - Tab Stud Diameter Length - Tab
94817 94817 3M
RFQ

Min: 1

Mult: 1

0 0x0x0 download Highland™ Free Hanging Free Hanging (In-Line) Bulk 1 (Unlimited) Crimp RoHS Compliant 2002 https://pdf.utmel.com/r/datasheets/3m-94800-datasheets-9760.pdf 19.812mm 4.52mm Blue Lead Free 3 Weeks 771.107029g Unknown Female Straight Brass Tin -14 AWG Butted Seam Vinyl 14-16 AWG 16 AWG 14 AWG Standard 0.780 19.81mm Brass Non-Mating End Insulated 0.145 (3.68mm) 0.020 0.51mm Tin 0.187 4.75mm
641324-2 641324-2 TE Connectivity AMP Connectors
RFQ

Min: 1

Mult: 1

0 0x0x0 download Faston, PIDG Free Hanging Free Hanging (In-Line) Tape & Reel (TR) 1 (Unlimited) Crimp RoHS Compliant 2006 /files/teconnectivityamp-6413242-datasheets-4969.pdf 17.811mm Yellow Not Applicable 4 Weeks ACTIVE (Last Updated: 1 week ago) yes Female Compliant No Straight EAR99 Brass Tin 8536.90.40.00 Nylon WIRE TERMINAL 24-26 AWG 0.24 mm2 26 AWG 24 AWG Standard 0.700 17.78mm Non-Mating End Insulated 0.082 (2.08mm) 2.794mm 0.020 0.51mm Yes 0.110 2.79mm 0.250 6.35mm
ED14-250MB-L ED14-250MB-L Panduit Corp $0.26
RFQ

Min: 1

Mult: 1

0 0x0x0 download StrongHold™ Free Hanging (In-Line) Bulk Not Applicable Crimp ROHS3 Compliant https://pdf.utmel.com/r/datasheets/panduitcorp-ed18250mbl-datasheets-5633.pdf 6 Weeks Male Brass 14-16 AWG Standard 0.690 17.53mm Non-Insulated 0.032 0.81mm Nickel 0.250 6.35mm
ED14-250MB-Q ED14-250MB-Q Panduit Corp $0.31
RFQ

Min: 1

Mult: 1

0 0x0x0 download StrongHold™ Free Hanging (In-Line) Bulk Not Applicable Crimp ROHS3 Compliant https://pdf.utmel.com/r/datasheets/panduitcorp-ed18250mbl-datasheets-5633.pdf 6 Weeks Male Brass 14-16 AWG Standard 0.690 17.53mm Non-Insulated 0.032 0.81mm Nickel 0.250 6.35mm
180422-2 180422-2 TE Connectivity AMP Connectors $0.44
RFQ

Min: 1

Mult: 1

0 0x0x0 download Fastin-Faston Free Hanging (In-Line), Right Angle Bulk 1 (Unlimited) Crimp RoHS Compliant 2004 https://pdf.utmel.com/r/datasheets/teconnectivityampconnectors-1804222-datasheets-5782.pdf 17.5768mm Not Applicable 13.3mm 14 Weeks ACTIVE (Last Updated: 4 days ago) yes Female Compliant No EAR99 Brass Tin 8536.90.40.00 WIRE TERMINAL 13-17 AWG 2.5 mm2 17 AWG 5 AWG Angled - 90°, Flag Non-Insulated 0.118 ~ 0.170 (3.00mm ~ 4.32mm) 7.92mm 0.032 0.81mm Yes 0.312 7.92mm 0.339 8.60mm
ED18-250-Q ED18-250-Q Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download StrongHold™ Free Hanging (In-Line) Bulk Not Applicable Crimp ROHS3 Compliant https://pdf.utmel.com/r/datasheets/panduitcorp-ed18250l-datasheets-5630.pdf 6 Weeks Female Brass 18-22 AWG Standard 0.660 16.76mm Non-Insulated 0.032 0.81mm Tin 0.250 6.35mm
DV14-205B-M DV14-205B-M Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download Pan-Term® Free Hanging Free Hanging (In-Line) Bulk Not Applicable Crimp ROHS3 Compliant 2006 18.8976mm 6.35mm Blue 6.4mm 4 Weeks Female EAR99 Brass Tin No 8536.90.40.00 Butted Seam Vinyl PUSH-ON TERMINAL 14-16 AWG 16 AWG 14 AWG Standard 0.744 18.90mm Non-Mating End Insulated 0.170 (4.32mm) 0.032 0.81mm 0.187 4.75mm 0.205 5.21mm
DV14-205B-3K DV14-205B-3K Panduit Corp $0.44
RFQ

Min: 1

Mult: 1

0 0x0x0 download Disco™ Free Hanging Free Hanging (In-Line) Reel Not Applicable Crimp ROHS3 Compliant 2005 https://pdf.utmel.com/r/datasheets/panduitcorp-dv14206b3k-datasheets-9732.pdf 19.558mm Blue 6.4mm 4 Weeks Female EAR99 Brass Tin No 8536.90.40.00 Butted Seam, Serrated Termination PUSH-ON TERMINAL 14-16 AWG 2.5 mm2 16 AWG 14 AWG Standard 0.770 19.56mm Non-Mating End Insulated 0.170 (4.32mm) 0.032 0.81mm 0.187 4.75mm 0.205 5.21mm
281091-2 281091-2 TE Connectivity AMP Connectors $0.56
RFQ

Min: 1

Mult: 1

0 0x0x0 download Faston Free Hanging Free Hanging (In-Line) Tape & Reel (TR) 1 (Unlimited) Crimp RoHS Compliant 1995 https://pdf.utmel.com/r/datasheets/teconnectivityampconnectors-2810912-datasheets-5790.pdf 28.9mm Not Applicable 22 Weeks ACTIVE (Last Updated: 3 days ago) yes Female Compliant Straight EAR99 Brass Tin 8536.90.40.00 PUSH-ON TERMINAL 7-10 AWG 8.5 mm2 10 AWG 7 AWG Standard 1.031 26.19mm Non-Insulated 0.201 ~ 0.275 (5.10mm ~ 6.99mm) 9.53mm 0.047 1.19mm No 1μm 0.375 9.53mm 0.469 11.90mm
0197114005 0197114005 Molex
RFQ

Min: 1

Mult: 1

0 0x0x0 download 19711 Through Hole, Right Angle Bulk 1 (Unlimited) Solder Non-RoHS Compliant https://pdf.utmel.com/r/datasheets/molex-0197114001-datasheets-9519.pdf no Male Brass PCB TERMINAL Angled - 90° Non-Insulated 0.032 0.81mm Tin-Lead 0.250 6.35mm
60080-2 60080-2 TE Connectivity AMP Connectors
RFQ

Min: 1

Mult: 1

0 0x0x0 download Faston Chassis Board, Chassis Bulk Not Applicable Screw, Rivet, Stud RoHS Compliant 2006 /files/teconnectivityampconnectors-600802-datasheets-5698.pdf 2.46mm 8.89mm Lead Free 8mm 4 Weeks ACTIVE (Last Updated: 3 days ago) Male Compliant Right Angle EAR99 Brass Tin No 8536.90.40.00 2 Tabs TAB TERMINAL 16 AWG 20 AWG Angled - 90° 3.18 mm Non-Insulated 6.35mm 0.032 0.81mm 0.250 6.35mm 2.46 mm
0190100027 0190100027 Molex
RFQ

Min: 1

Mult: 1

0 0x0x0 download Krimptite Free Hanging (In-Line) Bulk 1 (Unlimited) Crimp ROHS3 Compliant 3 Weeks Female and Male Brass 18-22 AWG Stacked 0.625 15.88mm Non-Insulated 0.032 0.81mm Tin 0.250 6.35mm 0.310 7.87mm
94825 94825 3M $0.28
RFQ

Min: 1

Mult: 1

0 0x0x0 download Highland™ Free Hanging Free Hanging (In-Line) Bulk 1 (Unlimited) Crimp RoHS Compliant 2002 https://pdf.utmel.com/r/datasheets/3m-94808-datasheets-8409.pdf 100 21.59mm 4.75mm Blue Contains Lead 3 Weeks 725.747792g Unknown Male Straight Copper Tin 16 AWG Butted Seam Vinyl 14-16 AWG 16 AWG 14 AWG Standard 0.850 21.59mm Copper Non-Mating End Insulated 0.145 (3.68mm) 0.020 0.51mm Tin 0.187 4.75mm
5-160583-2 5-160583-2 TE Connectivity AMP Connectors $0.58
RFQ

Min: 1

Mult: 1

0 0x0x0 download Faston, PIDG Free Hanging (In-Line) Tape & Reel (TR) 1 (Unlimited) Crimp RoHS Compliant 2007 22.1996mm Red Not Applicable 7.6mm 5 Weeks ACTIVE (Last Updated: 2 days ago) Female Compliant No Straight EAR99 Brass Tin 8536.90.40.00 Nylon WIRE TERMINAL 15.5-22 AWG 1.5 mm2 22 AWG 15 AWG Standard 0.874 22.20mm Non-Mating End Insulated 0.138 (3.51mm) 6.35mm 0.032 0.81mm Yes 0.250 6.35mm 0.303 7.70mm
5-160446-6 5-160446-6 TE Connectivity AMP Connectors $0.37
RFQ

Min: 1

Mult: 1

0 0x0x0 download Fastin-Faston Free Hanging Free Hanging (In-Line) Tape & Reel (TR) 1 (Unlimited) Crimp RoHS Compliant 2003 https://pdf.utmel.com/r/datasheets/teconnectivityampconnectors-51604465-datasheets-8866.pdf 19.2024mm Not Applicable Brass 18 Weeks ACTIVE (Last Updated: 1 week ago) Female Compliant No Straight Brass Silver No Brass Silver 13.5-17 AWG 17 AWG 5 AWG Standard 0.756 19.20mm Non-Insulated 0.118 ~ 0.161 (3.00mm ~ 4.09mm) 6.35mm 0.032 0.81mm Silver Yes Silver 0.250 6.35mm 0.305 7.75mm
160457-3 160457-3 TE Connectivity AMP Connectors
RFQ

Min: 1

Mult: 1

0 0x0x0 download Fastin-Faston Free Hanging Free Hanging (In-Line) Tape & Reel (TR) 1 (Unlimited) Crimp RoHS Compliant 1997 /files/teconnectivityamp-1604573-datasheets-4958.pdf 27.94mm Not Applicable 7.4mm 10 Weeks ACTIVE (Last Updated: 2 days ago) yes Male Compliant No Straight EAR99 Phosphor Bronze Silver 8536.90.40.00 Bronze TAB TERMINAL 14-18 AWG 2.1 mm2 18 AWG 14 AWG Standard 1.102 27.99mm 4 mm Non-Insulated 0.118 ~ 0.157 (3.00mm ~ 3.99mm) 6.35mm 0.032 0.81mm Yes 0.250 6.35mm 0.620 15.75mm
726389-2 726389-2 TE Connectivity AMP Connectors
RFQ

Min: 1

Mult: 1

0 0x0x0 download Faston Through Hole Through Hole, Right Angle Bulk 1 (Unlimited) Solder RoHS Compliant 2003 13mm Lead Free 12.8mm 18 Weeks ACTIVE (Last Updated: 3 days ago) yes Male Compliant Right Angle EAR99 Brass Tin No 8536.90.40.00 PCB TERMINAL Standard 1.4 mm Non-Insulated 4.75mm 0.020 0.51mm 4.5μm 0.187 4.75mm 0.252 6.40mm
ED18-250MB-Q ED18-250MB-Q Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download StrongHold™ Free Hanging (In-Line) Bulk Not Applicable Crimp ROHS3 Compliant https://pdf.utmel.com/r/datasheets/panduitcorp-ed18250mbl-datasheets-5633.pdf 6 Weeks Male Brass 18-22 AWG Standard 0.690 17.53mm Non-Insulated 0.032 0.81mm Nickel 0.250 6.35mm
EDV18-188B-L EDV18-188B-L Panduit Corp $0.28
RFQ

Min: 1

Mult: 1

0 0x0x0 download StrongHold™ Free Hanging (In-Line) Bulk Not Applicable Crimp ROHS3 Compliant https://pdf.utmel.com/r/datasheets/panduitcorp-edv18188bl-datasheets-5650.pdf Red 6 Weeks Female Brass Butted Seam 18-22 AWG Standard 0.790 20.07mm Non-Mating End Insulated 0.162 (4.11mm) 0.020 0.51mm Tin 0.187 4.75mm
DV14-187B-3K DV14-187B-3K Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download Disco™ Free Hanging Free Hanging (In-Line) Tape & Reel (TR) Not Applicable Crimp ROHS3 Compliant 2009 https://pdf.utmel.com/r/datasheets/panduitcorp-dv14206b3k-datasheets-9732.pdf 19.558mm Blue 5.8mm 4 Weeks Female EAR99 Brass Tin No 8536.90.40.00 Butted Seam, Serrated Termination PUSH-ON TERMINAL 14-16 AWG 2.5 mm2 16 AWG 14 AWG Standard 0.770 19.56mm Non-Mating End Insulated 0.170 (4.32mm) 0.032 0.81mm 0.187 4.75mm
ED18-188-L ED18-188-L Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download StrongHold™ Free Hanging (In-Line) Bulk Not Applicable Crimp ROHS3 Compliant https://pdf.utmel.com/r/datasheets/panduitcorp-ed18188l-datasheets-5580.pdf 6 Weeks Female Brass Serrated Termination 18-22 AWG Standard 0.580 14.73mm Non-Insulated 0.020 0.51mm Tin 0.187 4.75mm
0190090002 0190090002 Molex
RFQ

Min: 1

Mult: 1

0 0x0x0 download VibraKrimp Free Hanging (In-Line), Right Angle Tape & Reel (TR) 1 (Unlimited) Crimp ROHS3 Compliant https://pdf.utmel.com/r/datasheets/molex-0190090007-datasheets-8767.pdf 5 Weeks Female Brass 18-22 AWG Angled - 90°, Flag Non-Insulated 0.135 (3.43mm) 0.032 0.81mm Tin 0.250 6.35mm 0.305 7.75mm
DV18-205B-3K DV18-205B-3K Panduit Corp $0.34
RFQ

Min: 1

Mult: 1

0 0x0x0 download Disco™ Free Hanging Free Hanging (In-Line) Tape & Reel (TR) Not Applicable Crimp ROHS3 Compliant 2005 https://pdf.utmel.com/r/datasheets/panduitcorp-dv14206b3k-datasheets-9732.pdf 19.558mm Red 6.4mm 4 Weeks 3.674098kg Female EAR99 Brass Tin No 8536.90.40.00 Butted Seam, Serrated Termination Vinyl PUSH-ON TERMINAL 18-22 AWG 1.5 mm2 22 AWG 18 AWG Standard 0.770 19.56mm Non-Mating End Insulated 0.150 (3.81mm) 0.032 0.81mm 0.187 4.75mm 0.205 5.21mm
EDV18-250M-L EDV18-250M-L Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download StrongHold™ Free Hanging (In-Line) Bulk Not Applicable Crimp ROHS3 Compliant https://pdf.utmel.com/r/datasheets/panduitcorp-edv18250ml-datasheets-5665.pdf Red 6 Weeks Male Copper 18-22 AWG Standard 0.980 24.89mm Non-Mating End Insulated 0.154 (3.91mm) 0.032 0.81mm Nickel 0.250 6.35mm
D18-188-M D18-188-M Panduit Corp $0.29
RFQ

Min: 1

Mult: 1

0 0x0x0 download Pan-Term® Free Hanging Free Hanging (In-Line) Bulk Not Applicable Crimp ROHS3 Compliant 2006 14.7mm 5.84mm 5.8mm 4 Weeks Female EAR99 Brass Tin No 8536.90.40.00 Serrated Termination PUSH-ON TERMINAL 18-22 AWG 1 mm2 18 AWG 22 AWG Standard 0.580 14.73mm Non-Insulated 0.020 0.51mm 0.187 4.75mm
EDV18-250B-Q EDV18-250B-Q Panduit Corp $0.28
RFQ

Min: 1

Mult: 1

0 0x0x0 download StrongHold™ Free Hanging (In-Line) Bulk Not Applicable Crimp ROHS3 Compliant https://pdf.utmel.com/r/datasheets/panduitcorp-edv18250bl-datasheets-5602.pdf Red 6 Weeks Female Brass Serrated Termination 18-22 AWG Standard 0.810 20.57mm Non-Mating End Insulated 0.150 (3.81mm) 0.032 0.81mm Tin 0.250 6.35mm
DV14-188B-3K DV14-188B-3K Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download Disco™ Free Hanging Free Hanging (In-Line) Reel Not Applicable Crimp ROHS3 Compliant 2005 https://pdf.utmel.com/r/datasheets/panduitcorp-dv14206b3k-datasheets-9732.pdf 19.558mm Blue 5.8mm 4 Weeks Female Brass Tin No Butted Seam, Serrated Termination Brass Tin 14-16 AWG 16 AWG 14 AWG Standard 0.770 19.56mm Non-Mating End Insulated 0.170 (4.32mm) 0.020 0.51mm Tin 0.187 4.75mm
EDV18-250B-L EDV18-250B-L Panduit Corp $0.30
RFQ

Min: 1

Mult: 1

0 0x0x0 download StrongHold™ Free Hanging (In-Line) Bulk Not Applicable Crimp ROHS3 Compliant https://pdf.utmel.com/r/datasheets/panduitcorp-edv18250bl-datasheets-5602.pdf Red 6 Weeks Female Brass Serrated Termination 18-22 AWG Standard 0.810 20.57mm Non-Mating End Insulated 0.150 (3.81mm) 0.032 0.81mm Tin 0.250 6.35mm
41445 41445 TE Connectivity AMP Connectors $0.22
RFQ

Min: 1

Mult: 1

0 0x0x0 download Faston Free Hanging (In-Line) Bulk 1 (Unlimited) Crimp RoHS Compliant 1997 https://pdf.utmel.com/r/datasheets/teconnectivityampconnectors-414451-datasheets-1506.pdf 20.44mm Not Applicable 21 Weeks ACTIVE (Last Updated: 6 days ago) Female Compliant Straight EAR99 Brass 8536.90.40.00 PUSH-ON TERMINAL 16-18 AWG Standard 0.805 20.45mm Non-Insulated 0.120 ~ 0.145 (3.05mm ~ 3.68mm) 6.35mm 0.032 0.81mm Unplated No 0.250 6.35mm
D14-188-M D14-188-M Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download Pan-Term® Free Hanging Free Hanging (In-Line) Bulk Not Applicable Crimp ROHS3 Compliant 2006 14.732mm 5.84mm 5.8mm 4 Weeks Female EAR99 Brass Tin No 8536.90.40.00 Serrated Termination PUSH-ON TERMINAL 14-16 AWG 2.5 mm2 16 AWG 14 AWG Standard 0.580 14.73mm Non-Insulated 0.020 0.51mm 0.187 4.75mm

In Stock

Please send RFQ , we will respond immediately.