Compare Image Name Manufacturer Pricing(USD) Quantity Weight(Kg) Size(LxWxH) Part Status Series Mount Mounting Type Packaging Moisture Sensitivity Level (MSL) Termination Voltage - Rated RoHS Status Published Datasheet Length Width Color Lead Free Material Depth Factory Lead Time Weight Gender ECCN Code Contact Material Contact Plating Radiation Hardening HTS Code Feature Body Material Insulation Material Terminal and Terminal Block Type Body Plating Wire Gauge Wire Cross Section Wire Gauge (Max) Wire Gauge (Min) Terminal Type Length - Overall Insulation Insulation Diameter Tab Thickness Contact Finish Width - Tab Length - Tab
DMV6-63-2K DMV6-63-2K Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download Disco™ Free Hanging Free Hanging (In-Line) Tape & Reel (TR) Not Applicable Crimp RoHS Compliant 2006 https://pdf.utmel.com/r/datasheets/panduitcorp-dmv263b3k-datasheets-0867.pdf 21.1074mm Yellow 7.4mm 2 Weeks 4.898798kg Female EAR99 Electrolytic Copper No 8536.90.40.00 Serrated Termination Brass PUSH-ON TERMINAL Tin 10-12 AWG 12 AWG 10 AWG Standard 0.831 21.10mm Non-Mating End Insulated 0.230 (5.84mm) 0.032 0.81mm 0.250 6.35mm
DNF18-250-X DNF18-250-X Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download Pan-Term® Free Hanging Free Hanging (In-Line) Bulk Not Applicable Crimp RoHS Compliant 2009 20.574mm Red 7.4mm Female Brass Tin No Serrated Termination 18-22 AWG 22 AWG 18 AWG Standard 0.810 20.57mm Non-Mating End Insulated 0.040 ~ 0.138 (1.02mm ~ 3.51mm) 0.032 0.81mm Tin 0.250 6.35mm
DNF14-250M-3K DNF14-250M-3K Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download Disco™ Free Hanging Free Hanging (In-Line) Reel Not Applicable Crimp RoHS Compliant 2005 https://pdf.utmel.com/r/datasheets/panduitcorp-dnf14250m3k-datasheets-0881.pdf 22.9mm Blue 5.170953kg Male EAR99 Electrolytic Copper No 8536.90.40.00 Serrated Termination Copper Nylon TAB TERMINAL Nickel 14-16 AWG 2.5 mm2 14 AWG 16 AWG Standard 0.900 22.86mm Non-Mating End Insulated 0.162 (4.11mm) 0.032 0.81mm 0.250 6.35mm
DMPF2-63FIB-3K DMPF2-63FIB-3K Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download DiscoGrip™ Free Hanging Free Hanging (In-Line) Tape & Reel (TR) Not Applicable Crimp RoHS Compliant 2011 21.3106mm Blue 8.9mm 2 Weeks 4.808079kg Female EAR99 Electrolytic Copper No 8536.90.40.00 Brass PUSH-ON TERMINAL Tin 14-16 AWG 16 AWG 14 AWG Standard 0.839 21.30mm Fully Insulated 0.157 (3.99mm) 0.032 0.81mm 0.250 6.35mm
DPF18-205FIBR-C DPF18-205FIBR-C Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download DiscoGrip™ Free Hanging Free Hanging (In-Line) Bulk Not Applicable Crimp ROHS3 Compliant 2011 https://pdf.utmel.com/r/datasheets/panduitcorp-dpf18206fibm-datasheets-9961.pdf 19.812mm Red 7.9mm 4 Weeks Female EAR99 Brass Tin No 8536.90.40.00 Butted Seam PUSH-ON TERMINAL 18-22 AWG 22 AWG 18 AWG Standard 0.780 19.81mm Fully Insulated 0.060 ~ 0.106 (1.52mm ~ 2.69mm) 0.032 0.81mm 0.187 4.75mm 0.205 5.21mm
DMNF1-285-C DMNF1-285-C Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download Pan-Term® Free Hanging Free Hanging (In-Line) Bulk Not Applicable Crimp RoHS Compliant 2005 17.8054mm Red 3.8mm 63.502932g Female EAR99 Electrolytic Copper No 8536.90.40.00 Serrated Termination Brass WIRE TERMINAL Tin 18-22 AWG 1 mm2 22 AWG 18 AWG Standard 0.701 17.80mm Non-Mating End Insulated 0.098 (2.50mm) 0.020 0.51mm 0.110 2.79mm
0190160060 0190160060 Molex
RFQ

Min: 1

Mult: 1

0 0x0x0 download Krimptite Free Hanging (In-Line) Tape & Reel (TR) 1 (Unlimited) Crimp ROHS3 Compliant Female Brass 14-16 AWG Standard 0.570 14.48mm Non-Insulated 0.032 0.81mm Electro-Tin 0.110 2.79mm
DMV2-63B-3K DMV2-63B-3K Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download Disco™ Free Hanging Free Hanging (In-Line) Tape & Reel (TR) Not Applicable Crimp RoHS Compliant 2006 https://pdf.utmel.com/r/datasheets/panduitcorp-dmv263b3k-datasheets-0867.pdf 21.1074mm Blue 7.4mm 2 Weeks 4.195729kg Female EAR99 Electrolytic Copper No 8536.90.40.00 Serrated Termination Brass PUSH-ON TERMINAL Tin 14-16 AWG 16 AWG 14 AWG Standard 0.831 21.10mm Non-Mating End Insulated 0.178 (4.52mm) 0.032 0.81mm 0.250 6.35mm
DMV2-63P-L DMV2-63P-L Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download Pan-Term® Free Hanging Free Hanging (In-Line) Bulk Not Applicable Crimp RoHS Compliant 2011 https://pdf.utmel.com/r/datasheets/panduitcorp-dmnf163fiml-datasheets-0849.pdf 22.4028mm Blue Brass 92.986436g Female and Male EAR99 Electrolytic Copper Tin No 8536.90.40.00 Vinyl PUSH-ON TERMINAL 14-16 AWG 2.5 mm2 16 AWG 14 AWG Stacked 0.882 22.40mm Non-Mating End Insulated 0.160 (4.06mm) 0.032 0.81mm 0.250 6.35mm
DPF18206FIBR-3K DPF18206FIBR-3K Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download DiscoGrip™, ReelSmart™ Free Hanging Free Hanging (In-Line) Reel Not Applicable Crimp ROHS3 Compliant 2009 19.812mm Red 4 Weeks Female EAR99 Brass No 8536.90.40.00 Butted Seam PUSH-ON TERMINAL 18-22 AWG 1 mm2 22 AWG 18 AWG Standard 0.780 19.81mm Fully Insulated 0.060 ~ 0.106 (1.52mm ~ 2.69mm) 0.020 0.51mm Tin 0.187 4.75mm 0.205 5.21mm
DNFR18-205B-X DNFR18-205B-X Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download Pan-Term® Free Hanging Free Hanging (In-Line), Right Angle Bulk Not Applicable Crimp RoHS Compliant 2011 Red Female Brass Tin Butted Seam 18-22 AWG 22 AWG 18 AWG Angled - 90°, Flag Fully Insulated 0.130 (3.30mm) 0.032 0.81mm Tin 0.187 4.75mm 0.205 5.21mm
DNFR14-205B-X DNFR14-205B-X Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download Pan-Term® Free Hanging Free Hanging (In-Line), Right Angle Bulk Not Applicable Crimp RoHS Compliant 2011 Blue 2 Weeks Female Brass Tin Butted Seam 14-16 AWG 16 AWG 14 AWG Angled - 90°, Flag Fully Insulated 0.155 (3.94mm) 0.032 0.81mm Tin 0.187 4.75mm 0.205 5.21mm
DMV1-488B-3K DMV1-488B-3K Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download Disco™ Free Hanging Free Hanging (In-Line) Tape & Reel (TR) Not Applicable Crimp RoHS Compliant 2006 https://pdf.utmel.com/r/datasheets/panduitcorp-dmv263b3k-datasheets-0867.pdf 18.796mm Red 5.8mm 2 Weeks 3.674098kg Female EAR99 Electrolytic Copper No 8536.90.40.00 Serrated Termination Brass PUSH-ON TERMINAL Tin 18-22 AWG 22 AWG 18 AWG Standard 0.740 18.80mm Non-Mating End Insulated 0.160 (4.06mm) 0.032 0.81mm 0.187 4.75mm
DMNF1-485FIB-3K DMNF1-485FIB-3K Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download Pan-Term® Free Hanging Free Hanging (In-Line) Tape & Reel (TR) Not Applicable Crimp RoHS Compliant 2006 19.812mm Red 7.4mm 2 Weeks 3.764817kg Female EAR99 Electrolytic Copper No 8536.90.40.00 Butted Seam Brass PUSH-ON TERMINAL Tin 18-22 AWG 1 mm2 22 AWG 18 AWG Standard 0.780 19.81mm Fully Insulated 0.134 (3.40mm) 0.020 0.51mm 0.187 4.75mm
DMNF2-63FIBX-2K DMNF2-63FIBX-2K Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download Disco™ Free Hanging Free Hanging (In-Line) Tape & Reel (TR) Not Applicable Crimp RoHS Compliant 2006 https://pdf.utmel.com/r/datasheets/panduitcorp-dmnf263fibx2k-datasheets-0857.pdf 23.5966mm Blue 8.9mm 2 Weeks 3.900894kg Female EAR99 Electrolytic Copper No 8536.90.40.00 Butted Seam Brass PUSH-ON TERMINAL Tin 14-16 AWG 2.5 mm2 16 AWG 14 AWG Standard 0.929 23.60mm Fully Insulated 0.240 (6.10mm) 0.032 0.81mm 0.250 6.35mm
0190230069 0190230069 Molex
RFQ

Min: 1

Mult: 1

0 0x0x0 download InsulKrimp Free Hanging (In-Line) Bulk 1 (Unlimited) Crimp ROHS3 Compliant Yellow Male Brass 10-12 AWG Standard 1.100 27.94mm Non-Mating End Insulated 0.245 (6.22mm) 0.032 0.81mm Zinc 0.250 6.35mm 0.300 7.62mm
DMNF2-63FIB-C DMNF2-63FIB-C Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download Pan-Term® Free Hanging Free Hanging (In-Line) Bulk Not Applicable Crimp RoHS Compliant 2009 21.3106mm Blue 131.541787g Female EAR99 Electrolytic Copper 8536.90.40.00 Butted Seam PUSH-ON TERMINAL 14-16 AWG 2.5 mm2 16 AWG 14 AWG Standard 0.839 21.30mm Fully Insulated 0.156 (3.96mm) 0.032 0.81mm 0.250 6.35mm
0190160146 0190160146 Molex
RFQ

Min: 1

Mult: 1

0 0x0x0 download Krimptite Bulk 1 (Unlimited) Crimp ROHS3 Compliant 14-16 AWG
0357181610 0357181610 Molex
RFQ

Min: 1

Mult: 1

0 0x0x0 download Safelock Free Hanging Free Hanging (In-Line) Reel 1 (Unlimited) Crimp ROHS3 Compliant https://pdf.utmel.com/r/datasheets/molex-0357181610-datasheets-0845.pdf 15.7988mm Female Brass Tin No 22-24 AWG 24 AWG 22 AWG Standard 0.622 15.80mm Non-Insulated 0.142 (3.61mm) 0.020 0.51mm Tin 0.187 4.75mm 0.224 5.70mm
0190160057 0190160057 Molex
RFQ

Min: 1

Mult: 1

0 0x0x0 download Krimptite Free Hanging (In-Line) Tape & Reel (TR) 1 (Unlimited) Crimp ROHS3 Compliant Female Brass 14-16 AWG Standard 0.570 14.48mm Non-Insulated 0.020 0.51mm Electro-Tin 0.110 2.79mm
DMNF1-63FIM-L DMNF1-63FIM-L Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download Pan-Term® Free Hanging Free Hanging (In-Line) Bulk Not Applicable Crimp RoHS Compliant 2011 https://pdf.utmel.com/r/datasheets/panduitcorp-dmnf163fiml-datasheets-0849.pdf 22.9108mm Red 65.770894g Male EAR99 Electrolytic Copper 8536.90.40.00 Serrated Termination WIRE TERMINAL 18-22 AWG 1 mm2 22 AWG 18 AWG Standard 0.902 22.91mm Fully Insulated 0.133 (3.38mm) 0.032 0.81mm 0.250 6.35mm
0190160092 0190160092 Molex
RFQ

Min: 1

Mult: 1

0 0x0x0 download Krimptite Free Hanging (In-Line) Tape & Reel (TR) 1 (Unlimited) Crimp ROHS3 Compliant Female Brass 12-14 AWG Standard 0.627 15.93mm Non-Insulated 0.032 0.81mm Electro-Tin 0.250 6.35mm 0.313 7.95mm
DMNG1-63FL-3K DMNG1-63FL-3K Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download Disco-Lok™ Free Hanging Free Hanging (In-Line) Tape & Reel (TR) Not Applicable Crimp RoHS Compliant 2011 24.6126mm Red 9.1mm 2 Weeks Female EAR99 Electrolytic Copper No 8536.90.40.00 Brass PUSH-ON TERMINAL Tin 18-22 AWG 1 mm2 22 AWG 18 AWG Standard 0.969 24.61mm Fully Insulated 0.126 (3.20mm) 0.032 0.81mm 0.250 6.35mm
DMNF1-63FIB-C DMNF1-63FIB-C Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download Pan-Term® Free Hanging Free Hanging (In-Line) Bulk Not Applicable Crimp RoHS Compliant 2008 https://pdf.utmel.com/r/datasheets/panduit-dmnf163fibc-datasheets-0063.pdf 22.3012mm Red 127.005864g Female EAR99 Electrolytic Copper No 8536.90.40.00 Butted Seam PUSH-ON TERMINAL 18-22 AWG 1 mm2 22 AWG 18 AWG Standard 0.878 22.30mm Fully Insulated 0.132 (3.35mm) 0.032 0.81mm 0.250 6.35mm
DMNF2-488FIB-C DMNF2-488FIB-C Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download Pan-Term® Free Hanging Free Hanging (In-Line) Bulk Not Applicable Crimp 600V RoHS Compliant 2008 19.812mm 7.9mm Blue Brass 106.594207g Female EAR99 Electrolytic Copper Tin 8536.90.40.00 Butted Seam Nylon WIRE TERMINAL 14-16 AWG 2.5 mm2 16 AWG 14 AWG Standard 0.780 19.81mm Fully Insulated 0.156 (3.96mm) 0.032 0.81mm 0.187 4.75mm
0190160095 0190160095 Molex
RFQ

Min: 1

Mult: 1

0 0x0x0 download Krimptite Free Hanging (In-Line) Tape & Reel (TR) 1 (Unlimited) Crimp ROHS3 Compliant Female Brass 14-16 AWG Standard 0.627 15.93mm Non-Insulated 0.032 0.81mm 0.250 6.35mm 0.313 7.95mm
DMNF1-488-C DMNF1-488-C Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download Pan-Term® Free Hanging Free Hanging (In-Line) Bulk Not Applicable Crimp 300V RoHS Compliant 2005 19.6mm 5.8mm Red 5.8mm 122.46994g Female EAR99 Electrolytic Copper No 8536.90.40.00 Serrated Termination Brass Nylon WIRE TERMINAL Tin 18-22 AWG 1 mm2 22 AWG 18 AWG Standard 0.772 19.60mm Non-Mating End Insulated 0.142 (3.61mm) 0.032 0.81mm 0.187 4.75mm
DMNF1-63M-C DMNF1-63M-C Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download Pan-Term® Free Hanging Free Hanging (In-Line) Bulk Not Applicable Crimp RoHS Compliant 2005 https://pdf.utmel.com/r/datasheets/panduitcorp-dmnf163fiml-datasheets-0849.pdf 22.7076mm Red Lead Free 6.35mm 122.46994g Male EAR99 Electrolytic Copper No 8536.90.40.00 Serrated Termination Copper WIRE TERMINAL Nickel 18-22 AWG 1 mm2 22 AWG 18 AWG Standard 0.894 22.70mm Non-Mating End Insulated 0.156 (3.96mm) 0.032 0.81mm 0.250 6.35mm
DMNFR263FIB-KD DMNFR263FIB-KD Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download Disco™ Free Hanging Free Hanging (In-Line), Right Angle Tape & Reel (TR) Not Applicable Crimp RoHS Compliant 2007 https://pdf.utmel.com/r/datasheets/panduitcorp-dmnfr1485fibkd-datasheets-0825.pdf Blue 14.5mm 2 Weeks 3.447302kg Female EAR99 Electrolytic Copper No 8536.90.40.00 Butted Seam Brass PUSH-ON TERMINAL Tin 14-16 AWG 16 AWG 14 AWG Angled - 90° Fully Insulated 0.177 (4.50mm) 0.032 0.81mm 0.250 6.35mm
0190160063 0190160063 Molex
RFQ

Min: 1

Mult: 1

0 0x0x0 download Krimptite Free Hanging Free Hanging (In-Line) Tape & Reel (TR) 1 (Unlimited) Crimp ROHS3 Compliant https://pdf.utmel.com/r/datasheets/molex-0190160063-datasheets-0056.pdf 16.764mm Female Brass Tin 14-16 AWG 16 AWG 14 AWG Standard 0.660 16.76mm Non-Insulated 0.032 0.81mm Electro-Tin 0.250 6.35mm 0.310 7.87mm

In Stock

Please send RFQ , we will respond immediately.