Compare Image Name Manufacturer Pricing(USD) Quantity Weight(Kg) Size(LxWxH) Part Status Series Mount Mounting Type Packaging Moisture Sensitivity Level (MSL) Termination Max Operating Temperature Min Operating Temperature RoHS Status Published Datasheet Package / Case Length Width Color Lead Free Material Depth Factory Lead Time Weight Number of Pins Lifecycle Status Pbfree Code Connector Type Gender ELV Sealable Orientation ECCN Code Contact Material Contact Plating Radiation Hardening Reach Compliance Code HTS Code Feature Body Material Insulation Material Terminal and Terminal Block Type Body Plating Wire Gauge Wire Cross Section Wire Gauge (Max) Wire Gauge (Min) Wire/Cable Type Terminal Type Length - Overall Wire/Cable Diameter Insulation Insulation Diameter Mating Tab Width Tab Thickness Plating Insulated Wire Support Contact Finish Width - Tab Heavy Duty Keyed Stud Diameter Material Thickness Length - Tab
63657-1 63657-1 TE Connectivity AMP Connectors
RFQ

Min: 1

Mult: 1

0 0x0x0 download Amplivar Free Hanging Free Hanging (In-Line) Reel 1 (Unlimited) Crimp RoHS Compliant 2013 /files/teconnectivityampconnectors-636571-datasheets-9464.pdf 21.08mm Not Applicable 6 Weeks ACTIVE (Last Updated: 4 days ago) yes Male Compliant Straight EAR99 Brass 8536.90.40.00 TAB TERMINAL 12-14 AWG 14 AWG 12 AWG Standard 0.830 21.08mm Non-Insulated 6.35mm 0.032 0.81mm No Tin 0.250 6.35mm 0.315 8.00mm
928890-1 928890-1 TE Connectivity AMP Connectors
RFQ

Min: 1

Mult: 1

0 0x0x0 download Amplivar, Faston Free Hanging (In-Line) Reel 1 (Unlimited) Crimp RoHS Compliant 2007 https://pdf.utmel.com/r/datasheets/teconnectivityampconnectors-9288901-datasheets-9469.pdf 29.464mm 25 Weeks ACTIVE (Last Updated: 1 week ago) Male TAB TERMINAL Standard 1.122 28.50mm 3.302 mm Non-Insulated 0.098 ~ 0.138 (2.50mm ~ 3.51mm) 6.35mm 0.032 0.81mm Unplated 0.250 6.35mm 812.8μm 0.618 15.70mm
160915-1 160915-1 TE Connectivity AMP Connectors
RFQ

Min: 1

Mult: 1

0 0x0x0 download Faston Free Hanging Free Hanging (In-Line) Tape & Reel (TR) 1 (Unlimited) Crimp RoHS Compliant 2005 https://pdf.utmel.com/r/datasheets/teconnectivityampconnectors-1609152-datasheets-9129.pdf 18.9992mm Not Applicable 8 Weeks ACTIVE (Last Updated: 2 weeks ago) yes Female Compliant Straight EAR99 Phosphor Bronze 8536.90.40.00 Bronze PUSH-ON TERMINAL 17-20 AWG 1 mm2 20 AWG 17 AWG Standard 0.748 19.00mm Non-Insulated 0.055 ~ 0.091 (1.40mm ~ 2.31mm) 6.35mm 0.032 0.81mm Unplated No 0.250 6.35mm 0.303 7.70mm
0190090009 0190090009 Molex
RFQ

Min: 1

Mult: 1

0 0x0x0 download VibraKrimp Free Hanging (In-Line), Right Angle Reel 1 (Unlimited) Crimp ROHS3 Compliant https://pdf.utmel.com/r/datasheets/molex-0190090009-datasheets-9472.pdf 4 Weeks Female Brass 18-22 AWG Angled - 90°, Flag Non-Insulated 0.135 (3.43mm) 0.032 0.81mm Electro-Tin 0.187 4.75mm 0.250 6.35mm
2232995-1 2232995-1 TE Connectivity AMP Connectors
RFQ

Min: 1

Mult: 1

0 0x0x0 download Amplivar, Faston Free Hanging (In-Line) Reel Crimp RoHS Compliant 12 Weeks Female Phosphor Bronze 16-20 AWG Standard 0.690 17.53mm Non-Insulated 0.050 ~ 0.090 (1.27mm ~ 2.29mm) 0.032 0.81mm Tin 0.187 4.75mm 0.250 6.35mm
0190080028 0190080028 Molex
RFQ

Min: 1

Mult: 1

0 0x0x0 download Krimptite Free Hanging (In-Line), Right Angle Reel 1 (Unlimited) Crimp ROHS3 Compliant https://pdf.utmel.com/r/datasheets/molex-0190080028-datasheets-9478.pdf 5 Weeks Female Brass 14-16 AWG Angled - 90°, Flag Non-Insulated 0.020 0.51mm Electro-Tin 0.187 4.75mm 0.257 6.53mm
0190170117 0190170117 Molex
RFQ

Min: 1

Mult: 1

0 0x0x0 download InsulKrimp Free Hanging (In-Line) Bulk 1 (Unlimited) Crimp ROHS3 Compliant Red 13 Weeks Female Brass 18-22 AWG Standard 0.789 20.04mm Non-Mating End Insulated 0.130 (3.30mm) 0.020 0.51mm Electro-Tin 0.187 4.75mm 0.250 6.35mm
0190170112 0190170112 Molex
RFQ

Min: 1

Mult: 1

0 0x0x0 download InsulKrimp Free Hanging (In-Line) Tape & Reel (TR) 1 (Unlimited) Crimp ROHS3 Compliant https://pdf.utmel.com/r/datasheets/molex-0190170112-datasheets-9485.pdf Blue 4 Weeks Female Brass 14-16 AWG Standard 0.865 21.97mm Non-Mating End Insulated 0.140 (3.56mm) 0.032 0.81mm Electro-Tin 0.250 6.35mm 0.310 7.87mm
1478484-2 1478484-2 TE Connectivity AMP Connectors
RFQ

Min: 1

Mult: 1

0 0x0x0 download Free Hanging Free Hanging (In-Line) Reel 1 (Unlimited) Crimp, Reversed RoHS Compliant 1997 https://pdf.utmel.com/r/datasheets/teconnectivityampconnectors-14784841-datasheets-8923.pdf 22.28mm Not Applicable 25 Weeks ACTIVE (Last Updated: 1 week ago) yes Female Compliant No EAR99 Brass 8536.90.40.00 PUSH-ON TERMINAL 16-25 AWG 25 AWG 16 AWG Stator Non-Insulated 4.75mm 0.013 0.33mm Unplated Yes 0.187 4.75mm 0.247 6.27mm
62056-7 62056-7 TE Connectivity AMP Connectors $0.64
RFQ

Min: 1

Mult: 1

0 0x0x0 download Faston Free Hanging Free Hanging (In-Line), Right Angle Reel 1 (Unlimited) Crimp RoHS Compliant 2011 https://pdf.utmel.com/r/datasheets/teconnectivityampconnectors-620564-datasheets-7109.pdf 17.018mm Not Applicable Bronze 7 Weeks ACTIVE (Last Updated: 3 days ago) yes Female Compliant EAR99 Phosphor Bronze 8536.90.40.00 PUSH-ON TERMINAL 12-18 AWG 12 AWG 18 AWG Discrete Angled - 90°, Flag Non-Insulated 6.35mm 0.032 0.81mm No Tin 0.250 6.35mm 0.305 7.75mm
928960-2 928960-2 TE Connectivity AMP Connectors
RFQ

Min: 1

Mult: 1

0 0x0x0 download Mark I Free Hanging (In-Line) Reel 1 (Unlimited) Crimp RoHS Compliant 2004 Not Applicable Bronze 24 Weeks ACTIVE (Last Updated: 1 week ago) yes Socket Female Compliant Straight EAR99 Phosphor Bronze 8536.90.40.00 WIRE TERMINAL 9-11 AWG 6 mm2 Standard 0.878 22.30mm Non-Insulated 0.157 ~ 0.208 (3.99mm ~ 5.28mm) 6.35mm 0.032 0.81mm 0.250 6.35mm No
DNF14206FIBX-M DNF14206FIBX-M Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download Disco™ Free Hanging Free Hanging (In-Line) Reel Not Applicable Crimp RoHS Compliant 2005 https://pdf.utmel.com/r/datasheets/panduitcorp-dnf18250fibx2k-datasheets-9824.pdf 22.098mm 7.87mm Blue 4 Weeks Female EAR99 Brass unknown 8536.90.40.00 Serrated Termination Nylon WIRE TERMINAL 14-16 AWG 2.5 mm2 16 AWG 14 AWG Standard 0.870 22.10mm Fully Insulated 0.240 (6.10mm) 0.020 0.51mm Tin 0.187 4.75mm 0.205 5.21mm
0190080009 0190080009 Molex
RFQ

Min: 1

Mult: 1

0 0x0x0 download Krimptite Free Hanging (In-Line), Right Angle Reel 1 (Unlimited) Crimp ROHS3 Compliant https://pdf.utmel.com/r/datasheets/molex-0190090007-datasheets-8767.pdf 4 Weeks yes Female Brass PUSH-ON TERMINAL 18-22 AWG Angled - 90°, Flag Non-Insulated 0.032 0.81mm Electro-Tin 0.187 4.75mm 0.257 6.53mm
172765-1 172765-1 TE Connectivity AMP Connectors
RFQ

Min: 1

Mult: 1

0 0x0x0 download Mark II Free Hanging Free Hanging (In-Line), Right Angle Tape & Reel (TR) 1 (Unlimited) Crimp 105°C -40°C RoHS Compliant 2003 /files/teconnectivityampconnectors-1727651-datasheets-9358.pdf 21.59mm Not Applicable 7.8mm 19 Weeks ACTIVE (Last Updated: 4 months ago) yes Female Compliant No EAR99 Brass Tin 8536.90.40.00 PUSH-ON TERMINAL 12-14 AWG 3.37 mm2 14 AWG 12 AWG Discrete Angled - 90°, Flag 5.2 mm Non-Insulated 5.2 mm 6.35mm 0.032 0.81mm Yes 0.250 6.35mm 0.307 7.80mm
DV14-145M-M DV14-145M-M Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download Pan-Term® Free Hanging Free Hanging (In-Line) Bulk Not Applicable Crimp Non-RoHS Compliant 2001 https://pdf.utmel.com/r/datasheets/panduitcorp-dv18145mmy-datasheets-9945.pdf 24.638mm Blue Copper Male Copper Tin Brazed Seam, Serrated Termination Vinyl 14-16 AWG 16 AWG 14 AWG Standard 0.970 24.64mm Non-Mating End Insulated 0.170 (4.32mm) 0.032 0.81mm Tin 0.145 3.68mm
7826 7826 Keystone Electronics
RFQ

Min: 1

Mult: 1

0 0x0x0 download Through Hole Through Hole, Right Angle Bulk 1 (Unlimited) Solder ROHS3 Compliant https://pdf.utmel.com/r/datasheets/keystoneelectronics-1269-datasheets-9380.pdf 3.18mm Black Lead Free 6 Weeks 6 yes INTERCONNECTION DEVICE Male Right Angle EAR99 Steel 6 Tabs Thermoplastic Header Non-Mating End Insulated 0.032 0.81mm Tin 0.250 6.35mm 0.307 7.80mm
DNF18250FIBX-C DNF18250FIBX-C Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download Disco™ Free Hanging Free Hanging (In-Line) Bulk Not Applicable Crimp Non-RoHS Compliant 2009 /files/panduitcorp-dnf18205fibm-datasheets-0257.pdf 23.622mm 8.89mm Red Female EAR99 Brass unknown 8536.90.40.00 Serrated Termination Nylon WIRE TERMINAL 18-22 AWG 1 mm2 22 AWG 18 AWG Standard 0.930 23.62mm Fully Insulated 0.210 (5.33mm) 0.032 0.81mm Tin 0.250 6.35mm
0190090018 0190090018 Molex
RFQ

Min: 1

Mult: 1

0 0x0x0 download VibraKrimp Free Hanging (In-Line), Right Angle Reel 1 (Unlimited) Crimp ROHS3 Compliant https://pdf.utmel.com/r/datasheets/molex-0190090007-datasheets-8767.pdf 4 Weeks yes Female Brass PUSH-ON TERMINAL 14-16 AWG Angled - 90°, Flag Non-Insulated 0.145 (3.68mm) 0.032 0.81mm Electro-Tin 0.187 4.75mm 0.250 6.35mm
142241-2 142241-2 TE Connectivity AMP Connectors
RFQ

Min: 1

Mult: 1

0 0x0x0 download Faston Chassis Board, Chassis Bulk 1 (Unlimited) Screw, Rivet, Stud RoHS Compliant 2006 8mm 8 Weeks 2 ACTIVE (Last Updated: 3 days ago) yes Male Compliant EAR99 Brass Tin No 8536.90.40.00 2 Tabs WIRE TERMINAL Angled - 45° Non-Insulated 6.35mm 0.032 0.81mm 0.250 6.35mm 4.0894 mm 0.287 7.30mm
DV14-250B-L DV14-250B-L Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download Pan-Term® Free Hanging Free Hanging (In-Line) Bulk Not Applicable Crimp Non-RoHS Compliant 2001 20.574mm 7.37mm Blue Brass 56.699046g Female Brass Tin Serrated Termination Vinyl 14-16 AWG 14 AWG 16 AWG Standard 0.810 20.57mm Non-Mating End Insulated 0.170 (4.32mm) 0.032 0.81mm Tin 0.250 6.35mm
DNG18-250FB-C DNG18-250FB-C Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download SUPRA-GRIP™ Free Hanging Free Hanging (In-Line) Bulk Not Applicable Crimp Non-RoHS Compliant 2006 100 23.622mm 8.89mm Red 8.9mm 2 Weeks INTERCONNECTION DEVICE Female Brass compliant Nylon 18-22 AWG 22 AWG 18 AWG Standard 0.930 23.62mm Fully Insulated 0.126 (3.20mm) 0.032 0.81mm Tin 0.250 6.35mm
60376-1 60376-1 TE Connectivity AMP Connectors
RFQ

Min: 1

Mult: 1

0 0x0x0 download Free Hanging Free Hanging (In-Line) Tape & Reel (TR) 1 (Unlimited) Crimp RoHS Compliant 1997 https://pdf.utmel.com/r/datasheets/teconnectivityampconnectors-603761-datasheets-9393.pdf 13.97mm Not Applicable 5.97mm 5 Weeks ACTIVE (Last Updated: 2 days ago) yes Female Compliant Right Angle EAR99 Phosphor Bronze Tin 8536.90.40.00 Bronze WIRE TERMINAL 14-20 AWG 20 AWG 14 AWG Discrete Angled - 90°, Flag 4.318 mm Non-Insulated 0.120 ~ 0.170 (3.05mm ~ 4.32mm) Yes No 457μm
DR18-205B-C DR18-205B-C Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download Pan-Term® Free Hanging Free Hanging (In-Line), Right Angle Bulk Not Applicable Crimp Non-RoHS Compliant 2001 https://pdf.utmel.com/r/datasheets/panduitcorp-dr14205bc-datasheets-9205.pdf 13.5mm 6.35mm 13.7mm 2 Weeks Female EAR99 Brass Tin No compliant 8536.90.40.00 Butted Seam, Serrated Termination PUSH-ON TERMINAL 18-22 AWG 22 AWG 18 AWG Angled - 90°, Flag Non-Insulated 0.032 0.81mm 0.187 4.75mm 0.205 5.21mm
160533-5 160533-5 TE Connectivity AMP Connectors
RFQ

Min: 1

Mult: 1

0 0x0x0 download Faston Free Hanging (In-Line) Tape & Reel (TR) 1 (Unlimited) Crimp RoHS Compliant 2014 https://pdf.utmel.com/r/datasheets/teconnectivityampconnectors-1605331-datasheets-6718.pdf 16 Weeks Female EAR99 Phosphor Bronze No 8536.90.40.00 WIRE TERMINAL 17-20 AWG 1 mm2 Standard 0.551 14.00mm Non-Insulated 0.080 ~ 0.120 (2.03mm ~ 3.05mm) 0.020 0.51mm Tin 0.110 2.79mm 0.248 6.30mm
DR14-206B-C DR14-206B-C Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download Pan-Term® Free Hanging Free Hanging (In-Line), Right Angle Bulk Not Applicable Crimp Non-RoHS Compliant 2001 https://pdf.utmel.com/r/datasheets/panduitcorp-dr14205bc-datasheets-9205.pdf 14mm 6.35mm 13.7mm Female EAR99 Brass Tin No compliant 8536.90.40.00 Butted Seam, Serrated Termination PUSH-ON TERMINAL 14-16 AWG 16 AWG 14 AWG Angled - 90°, Flag Non-Insulated 0.020 0.51mm 0.187 4.75mm 0.205 5.21mm
DNFR18-206FIB-C DNFR18-206FIB-C Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download Pan-Term® Free Hanging Free Hanging (In-Line), Right Angle Bulk Not Applicable Crimp Non-RoHS Compliant 2001 15.2mm 9.4mm Red Female EAR99 Brass compliant 8536.90.40.00 Nylon PUSH-ON TERMINAL 18-22 AWG 22 AWG 18 AWG Angled - 90°, Flag Fully Insulated 0.178 (4.52mm) 0.020 0.51mm Tin 0.187 4.75mm 0.205 5.21mm
DNG14-187FB-C DNG14-187FB-C Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download SUPRA-GRIP™ Free Hanging Free Hanging (In-Line) Bulk Not Applicable Crimp Non-RoHS Compliant 2001 22.606mm 7.37mm Blue Lead Free INTERCONNECTION DEVICE Female Brass compliant Nylon 14-16 AWG 16 AWG 14 AWG Standard 0.890 22.61mm Fully Insulated 0.153 (3.89mm) 0.032 0.81mm Tin 0.187 4.75mm
DNG18-250FL-M DNG18-250FL-M Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download Disco-Lok™ Free Hanging Free Hanging (In-Line) Bulk Not Applicable Crimp Non-RoHS Compliant 2001 https://pdf.utmel.com/r/datasheets/panduitcorp-dng18250flc-datasheets-9300.pdf 24.638mm 9.14mm Red 9.1mm Female EAR99 Brass Tin No 8536.90.40.00 Nylon WIRE TERMINAL 18-22 AWG 1 mm2 22 AWG 18 AWG Standard 0.970 24.64mm Fully Insulated 0.060 ~ 0.126 (1.52mm ~ 3.20mm) 0.032 0.81mm 0.250 6.35mm
DR18-206B-M DR18-206B-M Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download Pan-Term® Free Hanging Free Hanging (In-Line), Right Angle Bulk Not Applicable Crimp Non-RoHS Compliant 2001 https://pdf.utmel.com/r/datasheets/panduitcorp-dr14205bc-datasheets-9205.pdf 13.5mm 6.35mm Brass 13.7mm 2 Weeks Female Brass Tin No Butted Seam, Serrated Termination Brass Tin 18-22 AWG 22 AWG 18 AWG Angled - 90°, Flag Non-Insulated 0.020 0.51mm Tin 0.187 4.75mm 0.205 5.21mm
DNF18-205FIB-C DNF18-205FIB-C Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download Pan-Term® Free Hanging Free Hanging (In-Line) Bulk Not Applicable Crimp Non-RoHS Compliant 2009 https://pdf.utmel.com/r/datasheets/panduitcorp-dnf18205fibm-datasheets-0257.pdf 19.812mm 7.87mm Red 2 Weeks 113.398093g Female EAR99 Brass compliant 8536.90.40.00 Serrated Termination Nylon PUSH-ON TERMINAL 18-22 AWG 1.5 mm2 22 AWG 18 AWG Standard 0.780 19.81mm Fully Insulated 0.136 (3.45mm) 0.032 0.81mm Tin 0.187 4.75mm 0.205 5.21mm

In Stock

Please send RFQ , we will respond immediately.