Compare Image Name Manufacturer Pricing(USD) Quantity Weight(Kg) Size(LxWxH) Part Status Series Mount Mounting Type Packaging Moisture Sensitivity Level (MSL) Max Operating Temperature Min Operating Temperature RoHS Status Published Datasheet Voltage - Rated DC Current Rating Voltage - Rated AC Factory Lead Time Approval Agency Number of Poles Radiation Hardening Actuator Type Illumination Current Rating (Amps) Breaker Type
R11-4-15.0A-B01CV-V R11-4-15.0A-B01CV-V Sensata-Airpax
RFQ

Min: 1

Mult: 1

0 0x0x0 download SNAPAK® Panel Mount 1 (Unlimited) RoHS Compliant https://pdf.utmel.com/r/datasheets/sensataairpax-r110500ab06ev-datasheets-4533.pdf 6 Weeks 1 Rocker 15A Magnetic (Hydraulic Delay)
R11-4-20.0A-40871-2-V R11-4-20.0A-40871-2-V Sensata-Airpax $14.30
RFQ

Min: 1

Mult: 1

0 0x0x0 download SNAPAK® Panel Mount 1 (Unlimited) RoHS Compliant https://pdf.utmel.com/r/datasheets/sensataairpax-r110500ab06ev-datasheets-4533.pdf 65V 250V 1 Rocker None 16A Magnetic (Hydraulic Delay)
PR11-61F-25.0A-34096-7 PR11-61F-25.0A-34096-7 Sensata-Airpax
RFQ

Min: 1

Mult: 1

0 0x0x0 download SNAPAK® Panel Panel Mount 1 (Unlimited) RoHS Compliant https://pdf.utmel.com/r/datasheets/sensataairpax-r110500ab06ev-datasheets-4533.pdf 6 Weeks 1 Push to Reset Magnetic (Hydraulic Delay)
R11-4-1.00A-B211CH-V R11-4-1.00A-B211CH-V Sensata-Airpax
RFQ

Min: 1

Mult: 1

0 0x0x0 download SNAPAK® Panel Mount 1 (Unlimited) RoHS Compliant https://pdf.utmel.com/r/datasheets/sensataairpax-r110500ab06ev-datasheets-4533.pdf 6 Weeks 1 Rocker Red 1A Magnetic (Hydraulic Delay)
R11-4-5.00A-B211CH-V R11-4-5.00A-B211CH-V Sensata-Airpax
RFQ

Min: 1

Mult: 1

0 0x0x0 download SNAPAK® Panel Mount 1 (Unlimited) RoHS Compliant https://pdf.utmel.com/r/datasheets/sensataairpax-r110500ab06ev-datasheets-4533.pdf 6 Weeks 1 Rocker Red 5A Magnetic (Hydraulic Delay)
T11-2-20.0A-01-10AL-V T11-2-20.0A-01-10AL-V Sensata-Airpax
RFQ

Min: 1

Mult: 1

0 0x0x0 download SNAPAK® Panel Mount Bulk 1 (Unlimited) RoHS Compliant https://pdf.utmel.com/r/datasheets/sensataairpax-r110500ab06ev-datasheets-4533.pdf 2A 6 Weeks 1 No Toggle 20A Magnetic (Hydraulic Delay)
R11-62F-15.0A-B01CV-V R11-62F-15.0A-B01CV-V Sensata-Airpax
RFQ

Min: 1

Mult: 1

0 0x0x0 download SNAPAK® Panel Mount 1 (Unlimited) RoHS Compliant https://pdf.utmel.com/r/datasheets/sensataairpax-r110500ab06ev-datasheets-4533.pdf 15A 250V 6 Weeks 1 Rocker 15A Magnetic (Hydraulic Delay)
R11-4-5.00A-B01CV-V R11-4-5.00A-B01CV-V Sensata-Airpax
RFQ

Min: 1

Mult: 1

0 0x0x0 download SNAPAK® Panel Mount 1 (Unlimited) RoHS Compliant https://pdf.utmel.com/r/datasheets/sensataairpax-r110500ab06ev-datasheets-4533.pdf 6 Weeks 1 Rocker 5A Magnetic (Hydraulic Delay)
T11-0-.500A-06-11AL-V T11-0-.500A-06-11AL-V Sensata-Airpax
RFQ

Min: 1

Mult: 1

0 0x0x0 download SNAPAK® Panel Mount 1 (Unlimited) RoHS Compliant https://pdf.utmel.com/r/datasheets/sensataairpax-r110500ab06ev-datasheets-4533.pdf 65V 250V 2 Rocker None 6A Magnetic (Hydraulic Delay)
T11-2-1.00A-01-10AL-V T11-2-1.00A-01-10AL-V Sensata-Airpax
RFQ

Min: 1

Mult: 1

0 0x0x0 download SNAPAK® Panel Panel Mount Bulk 1 (Unlimited) 85°C -40°C RoHS Compliant https://pdf.utmel.com/r/datasheets/sensataairpax-r110500ab06ev-datasheets-4533.pdf 1A 6 Weeks 1 No Toggle 1A Magnetic (Hydraulic Delay)
PP11-61F-1.00A-OB-V PP11-61F-1.00A-OB-V Sensata-Airpax
RFQ

Min: 1

Mult: 1

0 0x0x0 download SNAPAK® Panel Panel Mount Bulk 1 (Unlimited) 85°C -40°C RoHS Compliant /files/sensataairpax-r110500ab06ev-datasheets-4533.pdf 65V 1A 250V 1 No Push-Pull Plunger None 6A Magnetic (Hydraulic Delay)
PR11-0-.500A-XX-S-V PR11-0-.500A-XX-S-V Sensata-Airpax
RFQ

Min: 1

Mult: 1

0 0x0x0 download SNAPAK® Panel Mount 1 (Unlimited) RoHS Compliant https://pdf.utmel.com/r/datasheets/sensataairpax-r110500ab06ev-datasheets-4533.pdf 65V 250V 2 Push-Pull Plunger None 8A Magnetic (Hydraulic Delay)
1410-G110-P2F1-B04-1A 1410-G110-P2F1-B04-1A E-T-A
RFQ

Min: 1

Mult: 1

0 0x0x0 download 1410-G1 Panel Panel Mount 1 (Unlimited) RoHS Compliant https://pdf.utmel.com/r/datasheets/eta-1410l210l2f1s028a-datasheets-6918.pdf 50V 1A 250V 7 Weeks CSA C22.2 No 235, IEC 60934, UL1077 1 Push to Reset Thermal
IALK1-1REC4-38929-35 IALK1-1REC4-38929-35 Sensata-Airpax
RFQ

Min: 1

Mult: 1

0 0x0x0 download 1 (Unlimited) RoHS Compliant https://pdf.utmel.com/r/datasheets/sensataairpax-idlbxk13699840-datasheets-4322.pdf 6 Weeks
T11-1-.800A-01-11AL-V T11-1-.800A-01-11AL-V Sensata-Airpax
RFQ

Min: 1

Mult: 1

0 0x0x0 download SNAPAK® Panel Mount 1 (Unlimited) RoHS Compliant https://pdf.utmel.com/r/datasheets/sensataairpax-r110500ab06ev-datasheets-4533.pdf 6 Weeks 1 Toggle 800mA Magnetic (Hydraulic Delay)
0MCB030.Z 0MCB030.Z Littelfuse Inc.
RFQ

Min: 1

Mult: 1

0 0x0x0 download MAXI™ Holder Holder Bulk Not Applicable Non-RoHS Compliant 12V 30A 11 Weeks 1 Automatic Reset 30A
R11-4-1.00A-B01EV R11-4-1.00A-B01EV Sensata-Airpax
RFQ

Min: 1

Mult: 1

0 0x0x0 download Bulk 1 (Unlimited) RoHS Compliant 1A 6 Weeks 1 No
IAGF6-1REC4-38927-8 IAGF6-1REC4-38927-8 Sensata-Airpax
RFQ

Min: 1

Mult: 1

0 0x0x0 download 1 (Unlimited) RoHS Compliant 2014 https://pdf.utmel.com/r/datasheets/sensataairpax-ieg617230091v-datasheets-4052.pdf 6 Weeks
PP11-49-15.0A-OA-S PP11-49-15.0A-OA-S Sensata-Airpax
RFQ

Min: 1

Mult: 1

0 0x0x0 download SNAPAK® Panel Mount 1 (Unlimited) RoHS Compliant https://pdf.utmel.com/r/datasheets/sensataairpax-r110500ab06ev-datasheets-4533.pdf 6 Weeks 1 Push-Pull 15A Magnetic (Hydraulic Delay)
PP11-42-10.0A-OA-S PP11-42-10.0A-OA-S Sensata-Airpax
RFQ

Min: 1

Mult: 1

0 0x0x0 download SNAPAK® Panel Mount Bulk 1 (Unlimited) RoHS Compliant https://pdf.utmel.com/r/datasheets/sensataairpax-r110500ab06ev-datasheets-4533.pdf 10A 6 Weeks 1 No Push-Pull 10A Magnetic (Hydraulic Delay)
IAGF6-1REC4-38927-R75 IAGF6-1REC4-38927-R75 Sensata-Airpax
RFQ

Min: 1

Mult: 1

0 0x0x0 download IAG Panel Mount 1 (Unlimited) RoHS Compliant https://pdf.utmel.com/r/datasheets/sensataairpax-ieg617230091v-datasheets-4052.pdf 80V 250V 1 Lever None Magnetic (Hydraulic Delay)
T11-4-3.00A-06-11 T11-4-3.00A-06-11 Sensata-Airpax
RFQ

Min: 1

Mult: 1

0 0x0x0 download SNAPAK® Panel Mount 1 (Unlimited) RoHS Compliant https://pdf.utmel.com/r/datasheets/sensataairpax-r110500ab06ev-datasheets-4533.pdf 65V 250V 1 Toggle None 3A Magnetic (Hydraulic Delay)
PR11-3-10.0A-XX-V PR11-3-10.0A-XX-V
RFQ

Min: 1

Mult: 1

0 0x0x0
30056-50 30056-50 Littelfuse Inc. $18.59
RFQ

Min: 1

Mult: 1

0 0x0x0 download 813 Chassis Mount Non-RoHS Compliant https://pdf.utmel.com/r/datasheets/littelfuseinc-75912-datasheets-200.pdf 12V 17 Weeks 2 Automatic Reset None 50A
PR11-4-2.00A-XX-V PR11-4-2.00A-XX-V Sensata-Airpax
RFQ

Min: 1

Mult: 1

0 0x0x0 download SNAPAK® Panel Panel Mount Bulk 1 (Unlimited) 85°C -40°C RoHS Compliant /files/sensataairpax-r110500ab06ev-datasheets-4533.pdf 2A 6 Weeks 1 No Push to Reset 2A Magnetic (Hydraulic Delay)
R11-61-5.00A-35363-3-V R11-61-5.00A-35363-3-V Sensata-Airpax
RFQ

Min: 1

Mult: 1

0 0x0x0 download SNAPAK® Panel Panel Mount 1 (Unlimited) RoHS Compliant https://pdf.utmel.com/r/datasheets/sensataairpax-r110500ab06ev-datasheets-4533.pdf 6 Weeks 1 Rocker Magnetic (Hydraulic Delay)
R11-4-10.0A-B01CV-V R11-4-10.0A-B01CV-V Sensata-Airpax
RFQ

Min: 1

Mult: 1

0 0x0x0 download SNAPAK® Panel Mount 1 (Unlimited) RoHS Compliant https://pdf.utmel.com/r/datasheets/sensataairpax-r110500ab06ev-datasheets-4533.pdf 6 Weeks 1 Rocker 10A Magnetic (Hydraulic Delay)
PR11-62F-20.0A-37351-2-V PR11-62F-20.0A-37351-2-V Sensata-Airpax
RFQ

Min: 1

Mult: 1

0 0x0x0 download SNAPAK® Panel Mount 1 (Unlimited) RoHS Compliant https://pdf.utmel.com/r/datasheets/sensataairpax-r110500ab06ev-datasheets-4533.pdf 65V 250V 1 Push to Reset None 2A Magnetic (Hydraulic Delay)
R11-4-4.00A-B06CV-V R11-4-4.00A-B06CV-V Sensata-Airpax
RFQ

Min: 1

Mult: 1

0 0x0x0 download SNAPAK® Panel Panel Mount 1 (Unlimited) 85°C -40°C RoHS Compliant /files/sensataairpax-r110500ab06ev-datasheets-4533.pdf 4A 6 Weeks 1 Rocker 4A Magnetic (Hydraulic Delay)
PP11-41-3.00A-XX-S PP11-41-3.00A-XX-S Sensata-Airpax
RFQ

Min: 1

Mult: 1

0 0x0x0 download SNAPAK® Panel Mount 1 (Unlimited) RoHS Compliant https://pdf.utmel.com/r/datasheets/sensataairpax-r110500ab06ev-datasheets-4533.pdf 65V 250V 1 Push-Pull Plunger None 8A Magnetic (Hydraulic Delay)

In Stock

Please send RFQ , we will respond immediately.